Immersion & wet locations
Engineered for deep-water hydrostatic immersion and marine deployment per ISO 13628-5 / IEC 60092-350.
Product
REF 43330 3000 V hybrid electro-optical subsea ROV tether and umbilical cable combining 3000 V power conductors, single-mode optical fibers, screened pairs, Aramid strength braid and a yellow polyolefin jacket.
Typical values for this cable type, based on ISO 13628-5 / IEC 60092-350 — confirmed in the datasheet and quotation for your order.
Application fit
REF 43330 3000 V hybrid electro-optical subsea ROV tether and umbilical cable combining 3000 V power conductors, single-mode optical fibers, screened pairs, Aramid strength braid and a yellow polyolefin jacket.
Engineered for deep-water hydrostatic immersion and marine deployment per ISO 13628-5 / IEC 60092-350.
Suitable for subsea winch deployment, LARS sheaves and vertical marine suspension within 8–12 × OD.
Verified for fixed subsea structure routing, deck jumpers and seabed interconnections.
Not intended for high-cycle dry factory drag chains; select a dedicated拖链/drag-chain cable for indoor automation.
Subsea ROV Main Lift UmbilicalConstruction
Shown: REF 43330 (ISO 13628-5 / IEC 60092-350) featuring central 8-fiber loose-tube optical sub-unit, stranded bare copper power & control conductors and high-visibility yellow polyolefin subsea outer sheath (6-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central 8-Fiber Loose-Tube Optical Sub-Unit | Eight 9/125 µm single-mode optical fibers housed in a gel-filled loose tube with a protective polyolefin sub-sheathISO 13628-5 / IEC 60092-350 |
| 2 | Stranded Bare Copper Power & Control Conductors | 11 stranded electrolytic copper conductors (3000 V HV power & LV control) plus 3 interstitial bare copper drain/ground strandsISO 13628-5 / IEC 60092-350 |
| 3 | Special High-Dielectric Polyolefin Core Insulation | Color-coded cross-linked / high-density polyolefin insulation engineered for 3000 V subsea HV power transmissionISO 13628-5 / IEC 60092-350 |
| 4 | Fluid-Filled Interstices & Metallic Screen Tape | Hydrostatic gel/oil-filled core interstices wrapped with a helically lapped aluminium screen / barrier tapeISO 13628-5 / IEC 60092-350 |
| 5 | Polyolefin Inner Sheath & Aramid Fiber Strength Braid | Extruded polyolefin inner bedding sheath reinforced with a high-modulus aramid / synthetic fiber contra-helical strength braidISO 13628-5 / IEC 60092-350 |
| 6 | High-Visibility Yellow Polyolefin Subsea Outer Sheath | Abrasion-, cut-, and seawater-resistant yellow polyolefin outer jacket for high-visibility subsea ROV deploymentISO 13628-5 / IEC 60092-350 |
Built to ISO 13628-5 / IEC 60092-350 with central 8-fiber loose-tube optical sub-unit and high-visibility yellow polyolefin subsea outer sheath
Available in continuous subsea winch lengths or factory-moulded / socket-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, optical & hydrostatic test report
Technical data
Sizes
Manufactured to ISO 13628-5 / IEC 60092-350 for deep-water ROV, towed array, mooring and subsea production systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight in air ≈ kg/km | Breaking load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 43330 Subsea Construction Schedule (−40…+80 °C) | |||||||
| REF 43330 Standard Hybrid | 3×4.0 mm² (3 kV) + 2×(2×0.5) + 4×FO | Class 5 tinned Cu + SM/MM | 22.8 | 540 | 45.0 | 185 | |
| REF 43330 Heavy-Duty ROV | 3×6.0 mm² (3 kV) + 4×(2×0.5) + 6×FO | Class 5 tinned Cu + SM/MM | 26.5 | 730 | 65.0 | 215 | |
| REF 43330 Compact Inspection | 3×2.5 mm² (3 kV) + 1×(2×0.5) + 4×FO | Class 5 tinned Cu + SM/MM | 19.2 | 385 | 32.0 | 155 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×4.0 mm² (3 kV) + 4×FO | 5.09 | 3000 V HV / 600 V Aux | −40…+80 °C |
| 3×6.0 mm² (3 kV) + 6×FO | 3.39 | 3000 V HV / 600 V Aux | −40…+80 °C |
| 3×2.5 mm² (3 kV) + 4×FO | 8.21 | 3000 V HV / 600 V Aux | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR & dimensional verification (ISO 13628-5 / IEC 60092-350) | Electrical resistance, optical attenuation at 1310/1550 nm and OD within ISO 13628-5 / IEC 60092-350 tolerances | Every manufactured drum / assembly |
| High-voltage dielectric & insulation resistance test (ISO 13628-5 / IEC 60092-350) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / assembly |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & bend-over-sheave qualification (ISO 13628-5 / IEC 60092-350) | Verified structural and transmission integrity under deep-water pressure and tensile cycling across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.