Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 50531 (500 V 4×0.75 mm² Low-Density Polyolefin Floating Pool-Robot Cable, -9.2 g/m) & REF 49491 (2×0.75 + 2×0.34 mm² Extra-Flexible Pool Cleaner Cable) (IEC 60335-2-41, 300/500 V, -10 °C to +60 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60335-2-41 / Floating Pool-Robot Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
REF 50531 (500 V 4×0.75 mm² Low-Density Polyolefin Floating Pool-Robot Cable, -9.2 g/m) & REF 49491 (2×0.75 + 2×0.34 mm² Extra-Flexible Pool Cleaner Cable) (IEC 60335-2-41, 300/500 V, -10 °C to +60 °C, min. bend radius 6 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 50531 & REF 49491 (ROBOT DE PISCINE) (IEC 60335-2-41 / Floating Pool-Robot Cable Specification) featuring flexible copper cores (4×0.75 / 2×0.75+2×0.34), low-density buoyancy fillers (ref 50531) and floating low-density polyolefin jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Copper Cores (4×0.75 / 2×0.75+2×0.34) | 4×0.75 mm² PE cores (REF 50531, ≤27.3 Ω/km) or 2×0.75 + 2×0.34 mm² PVC (REF 49491) |
| 2 | Low-Density Buoyancy Fillers (REF 50531) | Four large-volume low-density foamed fillers providing –9.2 g/m positive buoyancy |
| 3 | Overall Assembling Binder Tape | Helical binder tape stabilizing the buoyant core bundle during flex & torsion |
| 4 | Floating Low-Density Polyolefin Jacket | Chlorine-resistant blue low-density polyolefin jacket (Ø 19.0 mm, 274 g/m in air) |
Built to IEC 60335-2-41 / Floating Pool-Robot Cable Specification with flexible copper cores (4×0.75 / 2×0.75+2×0.34) and floating low-density polyolefin jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60335-2-41 / Floating Pool-Robot Cable Specification for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 50531 & REF 49491 (ROBOT DE PISCINE) Construction Schedule (−10…+60 °C) | |||||||
| REF 50531 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 50531 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 50531 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 300/500 V (45–100 Ω data) | −10…+60 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 300/500 V (45–100 Ω data) | −10…+60 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 300/500 V (High-Power Hybrid) | −10…+60 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60335-2-41 / Floating Pool-Robot Cable Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60335-2-41 / Floating Pool-Robot Cable Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60335-2-41 / Floating Pool-Robot Cable Specification) | Zero dielectric breakdown and verified insulation resistance for 300/500 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60335-2-41 / Floating Pool-Robot Cable Specification) | Verified submersion integrity, tensile load and thermal stability across −10…+60 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.