Contact
2,000–2,500 m deep-sea neutrino telescope & seismic array cable2,000–2,500 m (260 bar)21×SMF SS Tubes + 600 VAramid Deep-Sea Array

REF 50580 & REF 39465 2,500m Subsea Neutrino Telescope & Seismic Cable260 bar Deep-Sea · 600 V · 2,000–2,500 m deep-sea neutrino telescope & seismic array cable

REF 50580 (2,500m 21-SMF SS-Tube + 9×1mm² XLPE Aramid-Braided Neutrino-Telescope Cable) & REF 39465 (2,000m 120-Ohm Shielded-Pair Aramid-Braided Seismic Detection Cable) (260 bar Deep-Sea, 600 V, -20 °C to +70 °C).

Water-resistant
EMC screen
Anti-torsion braid
Oil-resistant
Order designation
REF 50580 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per 260 bar Deep-Sea
Operating temp.
−20…+70 °C
Continuous subsea & marine service
Min. bend radius
12 × OD
Dynamic sheave & fixed routing
Core / conductor
3×7 SMF
21×SMF in 3 SS tubes
Outer protection
Aramid+PUR/HDPE
High-tenacity aramid braid
Standard
260 bar Deep-Sea
ITU-T G.652.D

Typical values for this cable type, based on ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is REF 50580 & REF 39465 right for your machine?

REF 50580 (2,500m 21-SMF SS-Tube + 9×1mm² XLPE Aramid-Braided Neutrino-Telescope Cable) & REF 39465 (2,000m 120-Ohm Shielded-Pair Aramid-Braided Seismic Detection Cable) (260 bar Deep-Sea, 600 V, -20 °C to +70 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: REF 50580 & REF 39465 (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard) featuring stainless-steel optical tubes (3×7 smf), 600 v power / seismic cores (9×1.0 mm²) and subsea pur / hdpe outer sheath (ø30 mm) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stainless-Steel Optical Tubes (3×7 SMF)21 single-mode 9/125 µm (200 kpsi) fibres in 3 stainless-steel loose tubes (260 bar)
2600 V Power / Seismic Cores (9×1.0 mm²)9×1.0 mm² XLPE cores (REF 50580) or 2×120 Ω pairs + 1×1.5 pair + 3 Cu ballast (REF 39465)
3Silicone Water-Blocking & PE Inner SheathSilicone compound interstitial filling + extruded polyethylene (PE) inner sheath
4Aramid Fibre Strength Braid (18,000 daN)High-tenacity aramid fibre braid rated for 18,000 daN (REF 50580) / 10,000 daN (REF 39465)
5Subsea PUR / HDPE Outer Sheath (Ø30 mm)Black polyurethane (REF 50580) or HDPE (REF 39465) outer jacket for 2,000–2,500 m depth

REF 50580 & REF 39465 — Standard Subsea & Marine Execution

Built to ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard with stainless-steel optical tubes (3×7 smf) and subsea pur / hdpe outer sheath (ø30 mm)

REF 50580 & REF 39465 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

REF 50580 & REF 39465 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard)
Core / conductor construction
Stainless-Steel Optical Tubes (3×7 SMF) — 21 single-mode 9/125 µm (200 kpsi) fibres in 3 stainless-steel loose tubes (260 bar)
Primary dielectric / buffering
600 V Power / Seismic Cores (9×1.0 mm²) — 9×1.0 mm² XLPE cores (REF 50580) or 2×120 Ω pairs + 1×1.5 pair + 3 Cu ballast (REF 39465)

Thermal

Continuous operating temperature
−20…+70 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Subsea PUR / HDPE Outer Sheath (Ø30 mm) — Black polyurethane (REF 50580) or HDPE (REF 39465) outer jacket for 2,000–2,500 m depth
Minimum bending radius
12 × OD
Hydrostatic, tensile & crush duty
Aramid Fibre Strength Braid (18,000 daN) — High-tenacity aramid fibre braid rated for 18,000 daN (REF 50580) / 10,000 daN (REF 39465)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
REF 50580 & REF 39465
Sheath colour & metre marking
Continuous metre-marked black outer finish (Aramid + PUR/HDPE (Ø30mm))
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard REF 50580 & REF 39465 subsea & marine configurations

Manufactured to ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
REF 50580 & REF 39465 Construction Schedule (−20…+70 °C)
REF 50580 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
REF 50580 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
REF 50580 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard)DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard)Verified submersion integrity, tensile load and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

260 bar Deep-Sea CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX REF 50580 & REF 39465 260 bar Deep-Sea 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define REF 50580 & REF 39465 (REF 50580 & REF 39465 2,500m Subsea Neutrino Telescope & Seismic Cable)?
REF 50580 & REF 39465 (REF 50580 & REF 39465 2,500m Subsea Neutrino Telescope & Seismic Cable) is manufactured in accordance with ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard for 600 V service over -20 °C to +70 °C. Its 5-layer construction comprises stainless-steel optical tubes (3×7 smf), 600 v power / seismic cores (9×1.0 mm²) and subsea pur / hdpe outer sheath (ø30 mm).
What is the minimum bending radius and operating temperature range for REF 50580 & REF 39465?
The minimum bending radius for REF 50580 & REF 39465 is 12 × OD across its continuous operating temperature range of -20 °C to +70 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of REF 50580 & REF 39465 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stainless-Steel Optical Tubes (3×7 SMF) — 21 single-mode 9/125 µm (200 kpsi) fibres in 3 stainless-steel loose tubes (260 bar); (02) 600 V Power / Seismic Cores (9×1.0 mm²) — 9×1.0 mm² XLPE cores (REF 50580) or 2×120 Ω pairs + 1×1.5 pair + 3 Cu ballast (REF 39465); (03) Silicone Water-Blocking & PE Inner Sheath — Silicone compound interstitial filling + extruded polyethylene (PE) inner sheath; (04) Aramid Fibre Strength Braid (18,000 daN) — High-tenacity aramid fibre braid rated for 18,000 daN (REF 50580) / 10,000 daN (REF 39465); (05) Subsea PUR / HDPE Outer Sheath (Ø30 mm) — Black polyurethane (REF 50580) or HDPE (REF 39465) outer jacket for 2,000–2,500 m depth.
What factory test certificates are supplied with REF 50580 & REF 39465?
Every production drum of REF 50580 & REF 39465 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for REF 50580 & REF 39465

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

REF 50580 & REF 39465 2,500m Subsea Neutrino Telescope & Seismic Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote