Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 50580 (2,500m 21-SMF SS-Tube + 9×1mm² XLPE Aramid-Braided Neutrino-Telescope Cable) & REF 39465 (2,000m 120-Ohm Shielded-Pair Aramid-Braided Seismic Detection Cable) (260 bar Deep-Sea, 600 V, -20 °C to +70 °C).
Typical values for this cable type, based on ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard — confirmed in the datasheet and quotation for your order.
Application fit
REF 50580 (2,500m 21-SMF SS-Tube + 9×1mm² XLPE Aramid-Braided Neutrino-Telescope Cable) & REF 39465 (2,000m 120-Ohm Shielded-Pair Aramid-Braided Seismic Detection Cable) (260 bar Deep-Sea, 600 V, -20 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 50580 & REF 39465 (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard) featuring stainless-steel optical tubes (3×7 smf), 600 v power / seismic cores (9×1.0 mm²) and subsea pur / hdpe outer sheath (ø30 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stainless-Steel Optical Tubes (3×7 SMF) | 21 single-mode 9/125 µm (200 kpsi) fibres in 3 stainless-steel loose tubes (260 bar) |
| 2 | 600 V Power / Seismic Cores (9×1.0 mm²) | 9×1.0 mm² XLPE cores (REF 50580) or 2×120 Ω pairs + 1×1.5 pair + 3 Cu ballast (REF 39465) |
| 3 | Silicone Water-Blocking & PE Inner Sheath | Silicone compound interstitial filling + extruded polyethylene (PE) inner sheath |
| 4 | Aramid Fibre Strength Braid (18,000 daN) | High-tenacity aramid fibre braid rated for 18,000 daN (REF 50580) / 10,000 daN (REF 39465) |
| 5 | Subsea PUR / HDPE Outer Sheath (Ø30 mm) | Black polyurethane (REF 50580) or HDPE (REF 39465) outer jacket for 2,000–2,500 m depth |
Built to ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard with stainless-steel optical tubes (3×7 smf) and subsea pur / hdpe outer sheath (ø30 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 50580 & REF 39465 Construction Schedule (−20…+70 °C) | |||||||
| REF 50580 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 50580 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 50580 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −20…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −20…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.652.D / 260 bar (2,500 m) Neutrino & Seismic Standard) | Verified submersion integrity, tensile load and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.