Contact
Floating low-density electro-optical EOD & MCM ROV tether2,400 V & 1,500 V HVd = 0.92–0.98 FloatingNon-Magnetic EOD/MCM

REF 50899 & REF 51332 2,400 V / 1,500 V Floating EOD/MCM ROV TetherSubsea EOD / MCM ROV · 1.8/3 kV · Floating low-density electro-optical eod & mcm rov

REF 50899 & REF 51332 2,400 V / 1,500 V Special-Polyolefin Electro-Optical Fibre-Braided Low-Density Floating (d=0.92–0.98) EOD & MCM ROV Tether Cable (Subsea EOD / MCM ROV, 1.8/3 kV, -25 °C to +70 °C, min. bend radius 10 × OD).

Water-resistant
Anti-torsion braid
EMC screen
Outdoor & humid
Order designation
REF 50899 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 kV
Tested per Subsea EOD / MCM ROV
Operating temp.
−25…+70 °C
Continuous subsea & marine service
Min. bend radius
10 × OD
Dynamic sheave & fixed routing
Core / conductor
3×0.93
2,400 V / 1,500 V HV conductors
Outer protection
Floating Yellow
Fibre-braided low-density polyolefin
Standard
Subsea EOD
MIL-STD

Typical values for this cable type, based on MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV — confirmed in the datasheet and quotation for your order.

Application fit

Is REF 50899 & REF 51332 right for your machine?

REF 50899 & REF 51332 2,400 V / 1,500 V Special-Polyolefin Electro-Optical Fibre-Braided Low-Density Floating (d=0.92–0.98) EOD & MCM ROV Tether Cable (Subsea EOD / MCM ROV, 1.8/3 kV, -25 °C to +70 °C, min. bend radius 10 × OD).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: REF 50899 & REF 51332 (MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV) featuring hv power conductors (3×0.93 / 3×0.6 mm²), signal cores / pairs and floating low-density polyolefin jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1HV Power Conductors (3×0.93 / 3×0.6 mm²)2,400 V tinned copper (REF 50899) or 1,500 V special alloy (REF 51332) in polyolefin
2Signal Cores / Pairs1×0.22 mm² plain copper (REF 50899) or 2×(2×0.34 mm²) sheathed alloy pairs (REF 51332)
3Optical Fibres (3×SMF / 2×MMF)3 tight-buffered 9/125 µm SM fibres (REF 50899) or 2 loose-tube 62.5/125 MMF (REF 51332)
4Polyolefin Inner Sheath & Fibre BraidSpecial polyolefin inner sheath + synthetic fibre braid (2,300 daN / 1,000 daN break)
5Floating Low-Density Polyolefin JacketYellow low-density polyolefin outer sheath (seawater density 0.98 / 0.92, Ø 14–15 mm)

REF 50899 & REF 51332 — Standard Subsea & Marine Execution

Built to MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV with hv power conductors (3×0.93 / 3×0.6 mm²) and floating low-density polyolefin jacket

REF 50899 & REF 51332 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

REF 50899 & REF 51332 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
1.8/3 kV (MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV)
Core / conductor construction
HV Power Conductors (3×0.93 / 3×0.6 mm²) — 2,400 V tinned copper (REF 50899) or 1,500 V special alloy (REF 51332) in polyolefin
Primary dielectric / buffering
Signal Cores / Pairs — 1×0.22 mm² plain copper (REF 50899) or 2×(2×0.34 mm²) sheathed alloy pairs (REF 51332)

Thermal

Continuous operating temperature
−25…+70 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Floating Low-Density Polyolefin Jacket — Yellow low-density polyolefin outer sheath (seawater density 0.98 / 0.92, Ø 14–15 mm)
Minimum bending radius
10 × OD
Hydrostatic, tensile & crush duty
Polyolefin Inner Sheath & Fibre Braid — Special polyolefin inner sheath + synthetic fibre braid (2,300 daN / 1,000 daN break)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
REF 50899 & REF 51332
Sheath colour & metre marking
Continuous metre-marked yellow outer finish (Floating Yellow Polyolefin)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard REF 50899 & REF 51332 subsea & marine configurations

Manufactured to MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
REF 50899 & REF 51332 Construction Schedule (−25…+70 °C)
REF 50899 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
REF 50899 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
REF 50899 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV)DC resistance at 20 °C / optical attenuation and outer diameter within MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV)Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV)Verified submersion integrity, tensile load and thermal stability across −25…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Subsea EOD / MCM ROV CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX REF 50899 & REF 51332 Subsea EOD / MCM ROV 1.8/3 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define REF 50899 & REF 51332 (REF 50899 & REF 51332 2,400 V / 1,500 V Floating EOD/MCM ROV Tether)?
REF 50899 & REF 51332 (REF 50899 & REF 51332 2,400 V / 1,500 V Floating EOD/MCM ROV Tether) is manufactured in accordance with MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV for 1.8/3 kV service over -25 °C to +70 °C. Its 5-layer construction comprises hv power conductors (3×0.93 / 3×0.6 mm²), signal cores / pairs and floating low-density polyolefin jacket.
What is the minimum bending radius and operating temperature range for REF 50899 & REF 51332?
The minimum bending radius for REF 50899 & REF 51332 is 10 × OD across its continuous operating temperature range of -25 °C to +70 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of REF 50899 & REF 51332 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) HV Power Conductors (3×0.93 / 3×0.6 mm²) — 2,400 V tinned copper (REF 50899) or 1,500 V special alloy (REF 51332) in polyolefin; (02) Signal Cores / Pairs — 1×0.22 mm² plain copper (REF 50899) or 2×(2×0.34 mm²) sheathed alloy pairs (REF 51332); (03) Optical Fibres (3×SMF / 2×MMF) — 3 tight-buffered 9/125 µm SM fibres (REF 50899) or 2 loose-tube 62.5/125 MMF (REF 51332); (04) Polyolefin Inner Sheath & Fibre Braid — Special polyolefin inner sheath + synthetic fibre braid (2,300 daN / 1,000 daN break); (05) Floating Low-Density Polyolefin Jacket — Yellow low-density polyolefin outer sheath (seawater density 0.98 / 0.92, Ø 14–15 mm).
What factory test certificates are supplied with REF 50899 & REF 51332?
Every production drum of REF 50899 & REF 51332 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per MIL-STD / Non-Magnetic Floating EOD & Mine-Clearance ROV, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for REF 50899 & REF 51332

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

REF 50899 & REF 51332 2,400 V / 1,500 V Floating EOD/MCM ROV Tether

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote