Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 50108 (Acoustique Armé Acier) 1,000 V / 500 V PE/PP-Insulated Copper-Braid Shielded Galvanized Steel-Wire Armoured (8,900 daN) PUR Underwater Acoustic Detection Cable (Subsea Acoustic SWA, 0.6/1 kV, -25 °C to +70 °C).
Typical values for this cable type, based on IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection — confirmed in the datasheet and quotation for your order.
Application fit
REF 50108 (Acoustique Armé Acier) 1,000 V / 500 V PE/PP-Insulated Copper-Braid Shielded Galvanized Steel-Wire Armoured (8,900 daN) PUR Underwater Acoustic Detection Cable (Subsea Acoustic SWA, 0.6/1 kV, -25 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 50108 (ACOUSTIQUE ARMÉ ACIER) (IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection) featuring composite conductors (1×4.0 + 2×1.0 + 3×0.6), watertight stranding & copper braid and polyurethane outer sheath (ø28 ± 1 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Composite Conductors (1×4.0 + 2×1.0 + 3×0.6) | 1×4.0 mm² PP (500 V) + 2×1.0 mm² PE (500 V) + 3×0.6 mm² PE (1,000 V) plain copper |
| 2 | Watertight Stranding & Copper Braid | Watertightness compound in voids + overall plain copper wire braid shield |
| 3 | HDPE Inner Sheath | Extruded high-density polyethylene inner bedding resisting hydrostatic pressure |
| 4 | Galvanized Steel Wire Armour (8,900 daN) | Helically served galvanized round steel wires (89 kN theoretical breaking strength) |
| 5 | Polyurethane Outer Sheath (Ø28 ± 1 mm) | Black abrasion- and seawater-resistant polyurethane (PUR) outer jacket |
Built to IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection with composite conductors (1×4.0 + 2×1.0 + 3×0.6) and polyurethane outer sheath (ø28 ± 1 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 50108 (ACOUSTIQUE ARMÉ ACIER) Construction Schedule (−25…+70 °C) | |||||||
| REF 50108 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 50108 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 50108 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −25…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −25…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −25…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / 8,900 daN Steel-Armoured Acoustic Detection) | Verified submersion integrity, tensile load and thermal stability across −25…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.