Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 37640 3 kV / 1 kV / 250 V Power, Signal, Control & 12-MMF Loose-Tube Double Contra-Helical Aramid-Braided (60,000 daN) PUR Subsea Trenching Machine Umbilical (Subsea Trencher 3 kV, 1.8/3 kV, -25 °C to +70 °C).
Typical values for this cable type, based on ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard — confirmed in the datasheet and quotation for your order.
Application fit
REF 37640 3 kV / 1 kV / 250 V Power, Signal, Control & 12-MMF Loose-Tube Double Contra-Helical Aramid-Braided (60,000 daN) PUR Subsea Trenching Machine Umbilical (Subsea Trencher 3 kV, 1.8/3 kV, -25 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 37640 (ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard) featuring optical sub-cable (12×62.5/125 mmf), shielded signal pairs (4×2×0.22 mm²) and pur inner sheath & 60,000 dan aramid braid (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Optical Sub-Cable (12×62.5/125 MMF) | 6 loose tubes (12 multimode fibres) stranded under a central PUR sub-sheath |
| 2 | Shielded Signal Pairs (4×2×0.22 mm²) | Flexible tinned Cu + XLPE + Al/PET foil & drain + individual XLPE sheath (250 V) |
| 3 | Control Triplets (6×3×1.0 mm², 1 kV) | Six triplets of extra-flexible plain copper with polyester elastomer insulation |
| 4 | 3 kV Power Conductors (17×25 mm²) | 17 flexible plain copper conductors with 3,000 V XLPE insulation (≤0.819 Ω/km) |
| 5 | PUR Inner Sheath & 60,000 daN Aramid Braid | Watertight core + PUR inner sheath + double contra-helical aramid braid + PUR jacket |
Built to ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard with optical sub-cable (12×62.5/125 mmf) and pur inner sheath & 60,000 dan aramid braid
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 37640 Construction Schedule (−25…+70 °C) | |||||||
| REF 37640 Type A (Standard Lift) | 3 × 10 mm² HV + 6×2×1.0 + 12F FIMT | Class 5 tinned Cu + 316L FIMT | 25.4 | 1,680 | 320.0 | 380 | |
| REF 37640 Type B (Heavy Work-Class) | 3 × 16 mm² HV + 8×2×1.0 + 12F FIMT | Class 5 tinned Cu + 316L FIMT | 32.2 | 2,650 | 480.0 | 485 | |
| REF 37640 Type C (Ultra-Deep Trencher) | 3 × 25 mm² HV + 12×2×1.0 + 24F FIMT | Class 5 tinned Cu + 316L FIMT | 38.1 | 3,890 | 680.0 | 570 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 10 mm² HV + 6×2×1.0 + 12F FIMT | 1.91 | 1.8/3 kV (≤0.35 dB/km SM) | −25…+70 °C |
| 3 × 16 mm² HV + 8×2×1.0 + 12F FIMT | 1.21 | 1.8/3 kV (≤0.35 dB/km SM) | −25…+70 °C |
| 3 × 25 mm² HV + 12×2×1.0 + 24F FIMT | 0.78 | 1.8/3 kV (≤0.35 dB/km SM) | −25…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO 13628-5 / 60,000 daN Aramid Subsea Trencher Standard) | Verified submersion integrity, tensile load and thermal stability across −25…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.