PVC/PUR drag-chain connection cable300/500 V PVC/PURDIN EN 50363-10-2 TMPU7.5 × OD Chain Bend

SERVO FD 95810 P 300/500 V Unscreened PVC/PUR Servo Cable-ChainEconomical TI2 PVC core + coolant-proof TMPU jacket drag-chain cable

SERVO FD 95810 P is a 300/500 V (UL 600 V) unscreened drag-chain control and servo connection cable pairing economical high-flex TI2 PVC core insulation with a cut-, oil- and coolant-resistant TMPU polyurethane outer jacket for wet CNC machine tools.

Oil-resistant
Flame-retardant
Ozone, UV & moisture
Anti-torsion braid
Order designation
SERVO FD 95810 P 12G0.75
Outer Ø ≈
10.0 mm
Copper weight
86 kg/km
Total weight ≈
160 kg/km
Min. bend R (chain)
75 mm
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
U0/U · UL/CSA 600 V AWM
Core / Sheath
PVC / PUR
TI2 PVC cores + TMPU outer jacket
Bend radius
7.5 × OD
moving in chain · 4 × OD fixed
Travel speed
4.0 m/s
gliding · 6.0 m/s unsupported
Temperature
−5…+70 °C
flexing · −40…+80 °C fixed
Cycle life
5–8M cycles
in wet CNC machine carriers

Typical values for this cable type, based on DIN VDE 0285 / DIN EN 50363-10-2 — confirmed in the datasheet and quotation for your order.

Application fit

Is SERVO FD 95810 P right for your machine?

Choose SERVO FD 95810 P when indoor machine-tool energy chains are splashed with aggressive cutting oils, synthetic coolants and metal chips that degrade a standard PVC outer sheath.

Energy chain / drag chain

Suitable

Short-pitch Class 6 cores and low-friction TMPU jacket deliver 5–8 million cycles in wet machine-tool carriers.

Fixed installation

Suitable

Notch-resistant PUR outer sheath allows direct routing across CNC machine beds without protective conduit.

Festoon & line chain

Suitable

Suitable for indoor and covered outdoor C-rail festoons exposed to oils, grease and UV.

VFD inverter to AC motor screened feeder

Not suitable

Unscreened 300/500 V connection cable; for EMC-shielded VFD servo leads use Shielded Servo Motor Power Cable.

Use Shielded Servo Motor Power Cable
Typical machinesWet CNC Lathes & Milling CentresAutomotive Powertrain Transfer LinesGrinding, Honing & Broaching MachinesHydraulic Press & Stamping LinesTimber, Stone & Glass Processing

Construction

Layer by layer

Shown: SERVO FD 95810 P 12G1.0 unscreened PVC/PUR drag-chain cable with black numbered TI2 PVC cores, green-yellow PE core, non-woven sliding wrap and silver-grey RAL 7001 TMPU polyurethane sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Superfine copper conductorBare copper, extra-fine wire strands (IEC 60228 Class 6)Short-pitch stranding for continuous bending fatigue resistance
2High-flex PVC core insulationModified low-friction PVC compound (TI2 per DIN EN 50363-3)Black cores with sequential white numbers + GNYE per EN 50334
3Low-torsion concentric layCores stranded in short-pitch concentric layers around central fillerPrevents corkscrew deformation in linear C-tracks
4Non-woven sliding fleece wrapSynthetic anti-friction fleece over core bundleDecouples PVC cores from outer PUR sheath during 7.5 × OD bending
5Coolant-proof PUR outer sheathHalogen-free polyether polyurethane (TMPU per DIN EN 50363-10-2), silver-grey RAL 7001Resists ester coolants, mineral oils, microbes, hydrolysis and metal swarf abrasion

SERVO FD 95810 P (G-version)

Includes green-yellow protective earth core + white-numbered black PVC cores inside a PUR outer jacket

SERVO FD 95810 P (X-version)

All white-numbered black PVC cores without GNYE for 24 V DC valve banks and machine-tool I/O

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0285 / DIN EN 50363-10-2. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
300/500 V (UL/CSA 600 V)
AC test voltage
4000 V AC (50 Hz, 5 min)
Mutual capacitance
≈ 120 pF/m at 800 Hz
Specific insulation resistance
> 20 GΩ·cm at 20 °C

Thermal

Temperature, flexing
−5 °C to +70 °C (+80 °C UL AWM)
Temperature, fixed installation
−40 °C to +80 °C
Max. conductor temperature
+70 °C (+80 °C UL AWM)
Short-circuit temperature
+160 °C (max. 5 s)

Mechanical

Min. bending radius, moving
7.5 × OD in energy chain
Min. bending radius, fixed
4 × OD
Max. travel speed
4 m/s gliding · 6 m/s unsupported
Max. acceleration
Up to 15 m/s²
Max. tensile load (dynamic)
15 N/mm² of total copper cross-section

Resistance

Oil & coolant resistance
DIN EN 50363-10-2 TMPU · UL Oil Res I & II
Flame retardance
IEC 60332-1-2 · UL 1581 FT1 / VW-1
Hydrolysis & microbes
Polyether PUR resistant to microbes (EN ISO 846)
Abrasion & notch
DIN ISO 4649 abrasion ≤ 35 mm³ (5× better than PVC)

Reference standards

Cable type (construction standard)
DIN EN 50525-2-51 cores + DIN EN 50363-10-2 sheath
Conductor
IEC 60228 Class 6 superfine copper
Product approvals
UL AWM Style 20233 / 21223 (80 °C 600 V) · CSA
RoHS & REACH
2011/65/EU (RoHS 2) & EC 1907/2006 compliant

Identification

Sheath colour
Silver-grey (RAL 7001) or Black (RAL 9005)
Core identification
Black cores with white numbers + GNYE (EN 50334)
Marking
TEBAOFLEX SERVO FD 95810 P <size> 300/500V PVC/PUR UL CE
Customs tariff (HS)
8544.49

Sizes

18 standard SERVO FD 95810 P (300/500 V PVC/PUR) configurations

Economical TI2 PVC core insulation with heavy-duty TMPU polyurethane outer jacket.

Dimensions & weights
Order designationCores × mm²Cross-sectionOuter Ø ≈
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
chain mm
Enquiry
0.50 mm² PVC/PUR drag-chain control cores
SERVO FD 95810 P 3G0.53G0.50.5 mm²5.4144140
SERVO FD 95810 P 4G0.54G0.50.5 mm²5.8194944
SERVO FD 95810 P 7G0.57G0.50.5 mm²7.0347552
SERVO FD 95810 P 12G0.512G0.50.5 mm²9.05812268
0.75 mm² PVC/PUR drag-chain control cores
SERVO FD 95810 P 3G0.753G0.750.75 mm²5.9225244
SERVO FD 95810 P 4G0.754G0.750.75 mm²6.4296348
SERVO FD 95810 P 7G0.757G0.750.75 mm²7.7509858
SERVO FD 95810 P 12G0.7512G0.750.75 mm²10.08616075
SERVO FD 95810 P 18G0.7518G0.750.75 mm²11.913023089
SERVO FD 95810 P 25G0.7525G0.750.75 mm²14.4180325108
1.00 mm² PVC/PUR drag-chain control cores
SERVO FD 95810 P 4G1.04G1.01.0 mm²6.9387752
SERVO FD 95810 P 7G1.07G1.01.0 mm²8.36712062
SERVO FD 95810 P 12G1.012G1.01.0 mm²10.811519881
1.50 mm² PVC/PUR drag-chain control & power cores
SERVO FD 95810 P 4G1.54G1.51.5 mm²7.85810458
SERVO FD 95810 P 7G1.57G1.51.5 mm²9.610116872
SERVO FD 95810 P 12G1.512G1.51.5 mm²12.517327694
2.50 mm² PVC/PUR drag-chain power cores
SERVO FD 95810 P 4G2.54G2.52.5 mm²9.49615870
SERVO FD 95810 P 5G2.55G2.52.5 mm²10.412019478
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • For sub-zero flexing down to −40 °C or tighter 5 × OD bend radii, select SERVO FD 05855 P (TPE/PUR).

Reel check

Will it fit your machine?

A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.

Check results

Drum core 100 mm is below 150 mmUse a larger drum core or a smaller cable size
180 m/min ≤ 240 m/minWithin the rated travel speed
Minimum bending radius
75 mm
Min. drum core diameter
≈ 150 mm
Cable weight on drum
2.4 kg
Copper content
1.3 kg
Indicative only: based on the datasheet outer diameter and 7.5 × OD bending radius. Current derating for wound layers per DIN VDE 0298-4 is assessed separately.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
4000 V AC high-voltage dielectric test4.0 kV AC for 5 min without breakdownEvery manufactured drum length
Conductor DC resistance checkWithin IEC 60228 Class 6 maximum at 20 °CEvery drum length
Sample tests
Reversed bending carrier endurance≥ 5 million double strokes at 7.5 × OD without core fractureQualification & periodic audit
TMPU oil, coolant & abrasion testPass DIN EN 50363-10-2 oil immersion and DIN ISO 4649 abrasion ≤ 35 mm³Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

CE (2014/35/EU Low Voltage Directive)UL AWM Style 20233 / 21223 (80 °C 600 V)RoHS 2 (2011/65/EU) & REACH Compliant

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SERVO FD 95810 P <size> 300/500V PVC/PUR UL CE
Delivery form
Non-returnable fumigated wooden drums or coils
Standard lengths
100 m · 500 m · 1000 m (cut lengths on request)
MOQ
100 m (stock sizes) · 300 m (custom)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

Why combine PVC core insulation with a PUR outer sheath in SERVO FD 95810 P?
In indoor CNC machining centres, the ambient temperature stays around +15 °C to +40 °C, so sub-zero TPE core insulation is not needed. However, synthetic water-miscible cutting emulsions, hydraulic oils, and sharp metal chips rapidly leach plasticisers out of a PVC outer jacket, causing it to harden and crack in the drag chain. SERVO FD 95810 P pairs cost-effective TI2 PVC cores with a chemical- and abrasion-proof TMPU polyurethane outer jacket, delivering 80 % of the service life of an all-TPE/PUR cable at a significantly lower cost.
When should I step up from SERVO FD 95810 P (PVC/PUR) to SERVO FD 05855 P (TPE/PUR)?
Step up to SERVO FD 05855 P when your energy chain requires a very tight bending radius of 5 × OD (instead of 7.5 × OD), operates in cold stores below −5 °C (down to −40 °C), exceeds 15 m/s² acceleration, or requires 100 % halogen-free certification across both insulation and jacket.
Is the polyether PUR outer sheath resistant to microbial degradation in machine-tool coolant sumps?
Yes. Unlike polyester-based polyurethanes that hydrolyse and rot when exposed to warm water-based emulsions and sump bacteria, our TMPU outer jacket is formulated from polyether polyurethane tested to EN ISO 846 for microbial and hydrolysis resistance.
Does SERVO FD 95810 P carry UL/CSA AWM recognition for North American export machinery?
Yes. The cable carries dual VDE 300/500 V and UL/CSA AWM Style 20233 / 21223 (80 °C, 600 V) recognition with FT1 / VW-1 flame retardance for NFPA 79 industrial machinery.

Request a quote

Get an engineering quote for SERVO FD 95810 P

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SERVO FD 95810 P 300/500 V Unscreened PVC/PUR Servo Cable-Chain

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp