Fixed installation
Distributed resistive carbon-filament conductor suppresses 64 MHz (1.5 T), 128 MHz (3 T) and 298 MHz (7 T) RF standing-wave currents.
Product
MR-conditional non-ferromagnetic carbon-composition biopotential lead compatible with BIOPAC LEAD108B / LEAD108C for simultaneous fMRI + ECG, EEG, EMG and EOG recording without RF loop heating or susceptibility artefacts.
Typical values for this cable type, based on ASTM F2503 /ASTM F2182 / IEC 60601-2-33 / ANSI/AAMI EC53 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered specifically for inside-bore physiological monitoring and simultaneous fMRI neuroscience research.
Distributed resistive carbon-filament conductor suppresses 64 MHz (1.5 T), 128 MHz (3 T) and 298 MHz (7 T) RF standing-wave currents.
Medical-grade TPU/silicone jacket resists hospital quaternary ammonium, isopropyl alcohol and hydrogen peroxide disinfectants.
Ultra-supple 3,000-filament carbon tow withstands repeated patient attachment and routing through MRI head coils.
Medical patient lead assembly is intended for clinical and research MRI suites, not industrial drag chains.
Use M8 Sensor CordsetConstruction
Representative LEAD108B / LEAD108C architecture: continuous 3K/6K carbon-fibre multi-filament resistive core + optional carbon-loaded semiconductive screen + USP Class VI medical TPU jacket + all-plastic/carbon electrode snap.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Multi-filament carbon-composition core | 3,000 to 6,000 continuous high-purity polyacrylonitrile (PAN) carbon filaments (distributed resistance 90–350 Ω/m, magnetic susceptibility χ ≈ −10⁻⁵)Eliminates metallic RF antenna resonance, eddy-current heating and B0 magnetic susceptibility artefacts |
| 2 | Medical-grade TPE / fluoroelastomer primary insulation | Flexible dielectric core insulation (2.0 kV dielectric withstand)Isolates biopotential signal path during high dB/dt EPI gradient switching |
| 3 | Optional carbon-polymer conductive screen (LEAD108C) | Extruded carbon-loaded conductive polymer shield layer (on screened LEAD108C variants)Attenuates gradient-switching electric-field pickup without introducing metal braiding into the MRI bore |
| 4 | Biocompatible USP Class VI medical TPU jacket | Smooth, non-tacky thermoplastic polyurethane (TPU) or platinum-cured silicone outer jacket (ISO 10993-5 / -10 biocompatible)Comfortable against patient skin and wipe-clean resistant to hospital disinfectants |
Single-core 2.3 mm OD carbon-composition lead with radiolucent carbon snap and 1.5 mm touch-proof DIN 42802 socket
Carbon-polymer screened or tightly twisted dual-carbon differential pair for minimal gradient artefact in 3T/7T EPI sequences
Technical data
Sizes
Compatible with BIOPAC MECMRI-BIOP / AMI100D, Brain Products, and clinical 1.5 mm DIN 42802 amplifier inputs.
| Order designation | Lead Architecture & Shielding | Electrode End | Length m | Unit R Ω/m | Total R Ω | Cable OD mm | MR Field Rating | Enquiry |
|---|---|---|---|---|---|---|---|---|
| LEAD108B Series — Unshielded Carbon-Composition Single Leads | ||||||||
| MRC-LEAD108B-SNAP-060 | Unshielded 3K Carbon Core | Carbon Snap (3.9 mm) | 0.60 | 110 | 66 | 2.3 | 1.5T / 3T / 7T | |
| MRC-LEAD108B-SNAP-100 | Unshielded 3K Carbon Core | Carbon Snap (3.9 mm) | 1.00 | 110 | 110 | 2.3 | 1.5T / 3T / 7T | |
| MRC-LEAD108B-SNAP-150 | Unshielded 3K Carbon Core (LEAD108B std) | Carbon Snap (3.9 mm) | 1.50 | 110 | 165 | 2.3 | 1.5T / 3T / 7T | |
| MRC-LEAD108B-SNAP-200 | Unshielded 3K Carbon Core | Carbon Snap (3.9 mm) | 2.00 | 110 | 220 | 2.3 | 1.5T / 3T | |
| MRC-LEAD108B-CLIP-150 | Unshielded 3K Carbon Core | Radiolucent Pinch Clip | 1.50 | 110 | 165 | 2.3 | 1.5T / 3T / 7T | |
| MRC-LEAD108B-HR-150 | High-Damping 300 Ω/m Carbon Core | Carbon Snap (3.9 mm) | 1.50 | 300 | 450 | 2.3 | 3T / 7T / 9.4T | |
| LEAD108C & Twisted Series — Carbon-Screened & Differential Pair Leads | ||||||||
| MRC-LEAD108C-SCR-100 | Carbon-Polymer Screened Coax | Carbon Snap (3.9 mm) | 1.00 | 120 | 120 | 3.2 | 1.5T / 3T / 7T | |
| MRC-LEAD108C-SCR-150 | Carbon-Polymer Screened Coax (LEAD108C std) | Carbon Snap (3.9 mm) | 1.50 | 120 | 180 | 3.2 | 1.5T / 3T / 7T | |
| MRC-LEAD108C-SCR-200 | Carbon-Polymer Screened Coax | Carbon Snap (3.9 mm) | 2.00 | 120 | 240 | 3.2 | 1.5T / 3T | |
| MRC-LEAD108-TP2-150 | 2-Lead Twisted Carbon Pair (Bipolar) | 2 × Carbon Snaps | 1.50 | 110 | 165 | 4.4 | 1.5T / 3T / 7T | |
| MRC-LEAD108-TP3-150 | 3-Lead Twisted Carbon Triad (+ / − / GND) | 3 × Carbon Snaps (R/W/B) | 1.50 | 110 | 165 | 5.0 | 1.5T / 3T / 7T | |
| MRC-LEAD108-TP3-300 | 3-Lead Twisted Carbon Triad (+ / − / GND) | 3 × Carbon Snaps (R/W/B) | 3.00 | 110 | 330 | 5.0 | 1.5T / 3T | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 100 % DC end-to-end carbon resistance & continuity check | Verify distributed resistance within ± 15 % of nominal specification | Every lead assembly |
| 1,500 V AC dielectric withstand test | Zero breakdown through medical TPU jacket for 60 s | Every production lot |
| Sample tests | ||
| ASTM F2182 phantom RF heating test at 64 MHz (1.5T) & 128 MHz (3T) | Temperature rise ΔT < 1.5 °C at electrode contact in gel phantom | Type qualification |
| ASTM F2119 gradient-echo & spin-echo susceptibility artefact test | Zero ferromagnetic distortion on 3.0 T EPI sequences | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.