Contact

MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-WireBS EN 50288-7 / PAS 5308 · 300/500 V · -30 °C to +90 °C industrial MSR-2XYQYPimf construction

MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-Wire Braided Instrument Cable (MSR-2X(St)YQYPimf) engineered to BS EN 50288-7 / PAS 5308 for 300/500 V service across -30 °C to +90 °C, featuring stranded bare & tinned copper conductor and pvc

Approved
Low-EMC design
EMC screen
Oil-resistant
Order designation
MSR-2X(St)YQYPimf 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Per BS EN 50288-7 / PAS 5308
Operating temp.
−30…+90 °C
Continuous thermal rating
Min. bend radius
10 × OD
Installed / fixed routing
Conductor
bare & tinned
High-conductivity bare & tinned
Outer layer
PVC outer sheath
Extruded PVC outer sheath protective
Standard
BS EN 50288-7
BS EN 50288-7 / PAS 5308

Typical values for this cable type, based on BS EN 50288-7 / PAS 5308 — confirmed in the datasheet and quotation for your order.

Application fit

Is MSR-2X(St)YQYPimf right for your machine?

MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-Wire Braided Instrument Cable (MSR-2X(St)YQYPimf) engineered to BS EN 50288-7 / PAS 5308 for 300/500 V service across -30 °C to +90 °C, featuring stranded bare & tinned copper conductor and pvc

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with BS EN 50288-7 / PAS 5308.

Offshore platform & shipboard deck trays

Suitable

Engineered and verified for offshore deck service in accordance with BS EN 50288-7 / PAS 5308.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Typical machinesOil & Gas CableRefinery & Petrochemical Process UnitsLNG Terminals & Tank FarmsOnshore & Offshore Oil & Gas FacilitiesChemical & Hydrocarbon Processing PlantsOffshore Oil & Gas Platforms & FPSOs

Construction

Layer by layer

Shown: MSR-2X(St)YQYPimf (BS EN 50288-7 / PAS 5308) with stranded bare & tinned copper conductor, al/polyester individual screen and pvc outer sheath (8-layer construction).

12345678
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded bare & tinned copper conductorHigh-conductivity bare & tinned copper conductor per BS EN 50288-7 / PAS 5308BS EN 50288-7 / PAS 5308
2Al/polyester individual screenAl/polyester individual screen metallic electromagnetic screen (individual core / group layer)BS EN 50288-7 / PAS 5308
3Yellow pair identification tapeHelically applied yellow pair identification tapeBS EN 50288-7 / PAS 5308
4XLPE core insulationExtruded XLPE dielectric (individual core / group layer)BS EN 50288-7 / PAS 5308
5Al/polyester overall screenAl/polyester overall screen metallic electromagnetic screen (lapped tape)BS EN 50288-7 / PAS 5308
6PVC inner sheathExtruded PVC inner sheath protective layer (continuous layer)BS EN 50288-7 / PAS 5308
7Galvanized steel wire braidGalvanized steel wire braid high-coverage braided layer (woven structure)BS EN 50288-7 / PAS 5308
8PVC outer sheathExtruded PVC outer sheath protective layer (continuous layer)BS EN 50288-7 / PAS 5308

MSR-2X(St)YQYPimf — Standard Execution

Built to BS EN 50288-7 / PAS 5308 with stranded bare & tinned copper conductor and pvc outer sheath

MSR-2X(St)YQYPimf — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per BS EN 50288-7 / PAS 5308

MSR-2X(St)YQYPimf — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS EN 50288-7 / PAS 5308. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300/500 V (BS EN 50288-7 / PAS 5308)
Conductor construction
Stranded bare & tinned copper conductor — High-conductivity bare & tinned copper conductor per BS EN 50288-7 / PAS 5308
Primary insulation / dielectric
Al/polyester individual screen — Al/polyester individual screen metallic electromagnetic screen (individual core / group layer)

Thermal

Continuous operating temperature
−30…+90 °C per BS EN 50288-7 / PAS 5308
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer sheath — Extruded PVC outer sheath protective layer (continuous layer)
Minimum bending radius
10 × OD (installed / static routing)
Layer count & geometry
8 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with BS EN 50288-7 / PAS 5308
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
BS EN 50288-7 / PAS 5308
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MSR-2X(St)YQYPimf
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard MSR-2X(St)YQYPimf cable configurations

Manufactured to BS EN 50288-7 / PAS 5308 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
MSR-2X(St)YQYPimf Standard Construction Schedule (300/500 V · −30…+90 °C)
MSR-2X(St)YQYPimf 1×2×0.51×2×0.5 mm²6.45852
MSR-2X(St)YQYPimf 2×2×0.52×2×0.5 mm²9.211274
MSR-2X(St)YQYPimf 4×2×0.54×2×0.5 mm²11.417692
MSR-2X(St)YQYPimf 8×2×0.58×2×0.5 mm²14.8295118
MSR-2X(St)YQYPimf 12×2×0.512×2×0.5 mm²17.6420141
MSR-2X(St)YQYPimf 1×2×1.01×2×1.0 mm²7.68661
MSR-2X(St)YQYPimf 2×2×1.02×2×1.0 mm²11.016888
MSR-2X(St)YQYPimf 4×2×1.04×2×1.0 mm²13.5264108
MSR-2X(St)YQYPimf 8×2×1.08×2×1.0 mm²17.9465143
MSR-2X(St)YQYPimf 1×2×1.51×2×1.5 mm²8.511468
MSR-2X(St)YQYPimf 4×2×1.54×2×1.5 mm²15.2348122
MSR-2X(St)YQYPimf 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per BS EN 50288-7 / PAS 5308.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (BS EN 50288-7 / PAS 5308)DC resistance at 20 °C and geometry within BS EN 50288-7 / PAS 5308 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (BS EN 50288-7 / PAS 5308)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (BS EN 50288-7 / PAS 5308)Full compliance with BS EN 50288-7 / PAS 5308 across −30…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS EN 50288-7 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MSR-2X(St)YQYPimf <size> BS EN 50288-7 300/500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MSR-2X(St)YQYPimf (MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-Wire Braided Instrument Cable)?
MSR-2X(St)YQYPimf (MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-Wire Braided Instrument Cable) is manufactured in accordance with BS EN 50288-7 / PAS 5308 for 300/500 V service over -30 °C to +90 °C. Its 8-layer construction comprises stranded bare & tinned copper conductor, al/polyester individual screen, yellow pair identification tape, xlpe core insulation, al/polyester overall screen, pvc inner sheath, galvanized steel wire braid, pvc outer sheath.
What is the minimum bending radius and installation temperature for MSR-2X(St)YQYPimf?
The minimum installed bending radius for MSR-2X(St)YQYPimf is 10 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of MSR-2X(St)YQYPimf arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded bare & tinned copper conductor (High-conductivity bare & tinned copper conductor per BS EN 50288-7 / PAS 5308); (02) Al/polyester individual screen (Al/polyester individual screen metallic electromagnetic screen (individual core / group layer)); (03) Yellow pair identification tape (Helically applied yellow pair identification tape); (04) XLPE core insulation (Extruded XLPE dielectric (individual core / group layer)); (05) Al/polyester overall screen (Al/polyester overall screen metallic electromagnetic screen (lapped tape)); (06) PVC inner sheath (Extruded PVC inner sheath protective layer (continuous layer)); (07) Galvanized steel wire braid (Galvanized steel wire braid high-coverage braided layer (woven structure)); (08) PVC outer sheath (Extruded PVC outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with MSR-2X(St)YQYPimf?
Every production drum or spool of MSR-2X(St)YQYPimf undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per BS EN 50288-7 / PAS 5308, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MSR-2X(St)YQYPimf

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MSR-2X(St)YQY-PiMF XLPE-Insulated Pair/Overall Screened Steel-Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote