Trailing & towing
Underground 1.1 kV roadway distribution, gate-end box jumpers, armoured face conveyors and stage loaders.
Product
Low-voltage 660/1,100 V underground mining cable to MGM 112 and BS 6708 in Type 201 (3 screened phase cores) and Type 211 (3 screened phase cores + 1 unscreened earth core) with GP8 EPR insulation, copper/nylon phase screens, steel PWA and PCP sheath.
Typical values for this cable type, based on MGM 112 / BS 6708 Type 201 & 211 — confirmed in the datasheet and quotation for your order.
Application fit
MGM 112 Type 201 and Type 211 add individual copper/nylon phase screens to a pliable-wire-armoured 660/1,100 V construction, preventing phase-to-phase arcing and ensuring immediate earth-fault tripping in gassy underground coal seams.
Underground 1.1 kV roadway distribution, gate-end box jumpers, armoured face conveyors and stage loaders.
Gassy mine gallery hangers, drift haulage feeders, pump stations and flameproof switchgear links.
Heavy-duty polychloroprene (RS4/EM2) outer jacket resists wet mine roadways, hydraulic oil and rock abrasion.
Pliable wire armour is engineered for roadway and machine interconnections, not high-speed crane drums.
Use NSHTÖU ReelingConstruction
Shown: MGM 112 Type 211 3×50+1×25 — 3 EPR-insulated 50 mm² phase cores with individual copper/nylon braid screens + 1 unscreened 25 mm² earth core around a central elastomeric cradle, rubber inner bedding, galvanised steel pliable wire armour (PWA) and black PCP outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned copper conductor | Fine-stranded annealed tinned copper wire (IEC 60228 / BS EN 60228 Class 5)IEC 60228 Class 5 |
| 2 | EPR core insulation | Cross-linked ethylene-propylene rubber compound Type GP8 (+90 °C rated)BS 7655-1.2 GP8 / MGM 112 |
| 3 | Individual phase screen | Composite tinned-copper and nylon (polyamide) braid screen over each of the 3 phase coresMGM 112 / BS 6708 Type 201 & 211 |
| 4 | Elastomeric cradle center | Extruded rubber cradle separator maintaining core spacing under radial impactMGM 112 / BS 6708 |
| 5 | Elastomeric inner bedding | Extruded vulcanised rubber inner sheath over the cabled core assemblyMGM 112 inner bedding |
| 6 | Pliable wire armour (PWA) | Stranded galvanised steel wire armour (PWA) providing high crush resistance and earth-fault returnMGM 112 / BS 6708 PWA |
| 7 | Heavy-duty PCP outer sheath | Cross-linked polychloroprene (PCP / Type RS4 / EM2) extra-heavy-duty outer sheath, blackBS 7655-2.1 / IEC 60332-1-2 |
3 individually copper/nylon-screened 660/1,100 V phase cores around rubber cradle + inner sheath + PWA + PCP jacket
3 individually copper/nylon-screened 660/1,100 V phase cores + 1 unscreened earth core around cradle + inner sheath + PWA + PCP jacket
Technical data
Sizes
Typical MGM 112 / BS 6708 Type 201 & 211 outer diameter limits, copper content and cable weight.
| Order designation | Cores × mm² | AWG ≈ | Outer Ø min mm | Outer Ø max mm | Copper kg/km | Weight ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| MGM 112 Type 201 — 3 Screened Phase Cores + Pliable Wire Armour (660/1,100 V) | ||||||||
| MGM 112 Type 201 3×6 | 3×6 | 10 | 22.5 | 24.5 | 240 | 1,020 | 147 | |
| MGM 112 Type 201 3×10 | 3×10 | 8 | 25.4 | 27.6 | 360 | 1,340 | 166 | |
| MGM 112 Type 201 3×16 | 3×16 | 6 | 28.3 | 30.8 | 540 | 1,740 | 185 | |
| MGM 112 Type 201 3×25 | 3×25 | 4 | 32.0 | 34.8 | 810 | 2,290 | 209 | |
| MGM 112 Type 201 3×35 | 3×35 | 2 | 35.0 | 38.0 | 1,100 | 2,820 | 228 | |
| MGM 112 Type 201 3×50 | 3×50 | 1 | 38.8 | 42.2 | 1,540 | 3,580 | 253 | |
| MGM 112 Type 201 3×70 | 3×70 | 2/0 | 43.1 | 46.8 | 2,120 | 4,560 | 281 | |
| MGM 112 Type 211 — 3 Screened Phase Cores + 1 Earth Core + Pliable Wire Armour (660/1,100 V) | ||||||||
| MGM 112 Type 211 3×16+1×16 | 3×16+1×16 | 6 | 30.7 | 33.4 | 690 | 2,060 | 200 | |
| MGM 112 Type 211 3×25+1×16 | 3×25+1×16 | 4 | 34.2 | 37.2 | 960 | 2,640 | 223 | |
| MGM 112 Type 211 3×35+1×25 | 3×35+1×25 | 2 | 37.5 | 40.8 | 1,340 | 3,290 | 245 | |
| MGM 112 Type 211 3×50+1×25 | 3×50+1×25 | 1 | 41.6 | 45.2 | 1,780 | 4,120 | 271 | |
| MGM 112 Type 211 3×70+1×35 | 3×70+1×35 | 2/0 | 46.0 | 50.0 | 2,460 | 5,210 | 300 | |
| MGM 112 Type 211 3×95+1×50 | 3×95+1×50 | 3/0 | 51.0 | 55.4 | 3,350 | 6,540 | 332 | |
| MGM 112 Type 211 3×120+1×70 | 3×120+1×70 | 4/0 | 55.2 | 60.0 | 4,280 | 7,890 | 360 | |
| MGM 112 Type 211 3×150+1×95 | 3×150+1×95 | 300 kcmil | 59.6 | 64.8 | 5,400 | 9,450 | 389 | |
| Cross-section mm² | AWG ≈ | Max. DC resistance 20 °C, Ω/km | 1-core in air 30 °C, A | 3–4 core in air 30 °C, A |
|---|---|---|---|---|
| 6 | 10 | 3.39 | 53 | 44 |
| 10 | 8 | 1.95 | 74 | 61 |
| 16 | 6 | 1.24 | 99 | 82 |
| 25 | 4 | 0.795 | 131 | 108 |
| 35 | 2 | 0.565 | 162 | 135 |
| 50 | 1 | 0.393 | 202 | 168 |
| 70 | 2/0 | 0.277 | 250 | 207 |
| 95 | 3/0 | 0.21 | 301 | 250 |
| 120 | 4/0 | 0.164 | 352 | 292 |
| 150 | 300 kcmil | 0.132 | 404 | 335 |
Reel check
A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC voltage test | 3.0 kV AC (50 Hz) | Every manufactured length |
| Conductor DC resistance | IEC 60228 Class 5 (tinned copper) | Every manufactured length |
| Sample tests | ||
| Vertical flame propagation | IEC 60332-1-2 / EN 60332-1-2 | Per production batch |
| Insulation & sheath elastomer physical properties | MGM 112 / BS 6708 Type 201 & 211 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.