Mine roadway & tunnel wall hangers
Engineered for methane-hazard underground coal and hard-rock mine roadways, longwall faces and Ex-i barriers.
Product
L-2YYQY 300/500 V steel-braid-armoured Ex-i mining hybrid cable combining 2 × 6 mm² PE power cores, 2 × (2 × 0.5 mm²) screened control pairs and a 1 × 0.5 mm² pilot core under galvanized steel wire braid armour and a blue PVC Ex-i sheath.
Typical values for this cable type, based on IEC 60079-14 / PN-G-91006 — confirmed in the datasheet and quotation for your order.
Application fit
L-2YYQY 300/500 V steel-braid-armoured Ex-i mining hybrid cable combining 2 × 6 mm² PE power cores, 2 × (2 × 0.5 mm²) screened control pairs and a 1 × 0.5 mm² pilot core under galvanized steel wire braid armour and a blue PVC Ex-i sheath.
Engineered for methane-hazard underground coal and hard-rock mine roadways, longwall faces and Ex-i barriers.
Class 5 flexible conductors and steel wire braid support semi-mobile longwall monorail and stage-loader loops.
Galvanized steel wire braid (Q) provides cut and crush protection along mine gallery brackets.
Not intended for high-speed spring or motorised reeling drums; select a PUR/PCP reeling cable.
HSC-5-7X2SVA-2Construction
Shown: L-2YYQY (IEC 60079-14 / PN-G-91006) featuring power cores (2x6 mm²), screened control pairs (2x2x0.5 mm²) and intrinsically safe outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Power Cores (2x6 mm²) | Two 6.0 mm² Class 5 flexible plain annealed copper power cores with low-capacitance polyethylene (PE) insulation (Blue and Black)IEC 60079-14 / PN-G-91006 |
| 2 | Screened Control Pairs (2x2x0.5 mm²) | Two twisted 0.5 mm² PE-insulated control pairs (Blue/Grey & Blue/White), each wrapped with PET tape and an individual tinned copper braidIEC 60079-14 / PN-G-91006 |
| 3 | Unscreened Control Core (1x0.5 mm²) | One 0.5 mm² Class 5 flexible plain copper auxiliary control conductor with brown polyethylene (PE) insulationIEC 60079-14 / PN-G-91006 |
| 4 | Inner Sheath & Steel Braid Armour | Extruded grey PVC inner bedding sheath protected by a galvanized steel wire braid armour (Q) against rockfall and crush hazardsIEC 60079-14 / PN-G-91006 |
| 5 | Intrinsically Safe Outer Sheath | Blue flame-retardant polyvinyl chloride (PVC) outer sheath identifying intrinsically safe (Ex-i) underground mining circuitsIEC 60079-14 / PN-G-91006 |
Built to IEC 60079-14 / PN-G-91006 with power cores (2x6 mm²) and intrinsically safe outer sheath
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60079-14 / PN-G-91006 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| L-2YYQY Construction Schedule (−30…+70 °C) | |||||||
| L-2YYQY 2×4+2×(2×0.5)+1×0.5 | 2×4 + 2×(2×0.5) + 1×0.5 mm² | Class 5 Cu + Cu screen + Q braid | 16.8 | 420 | 3.8 | 170 | |
| L-2YYQY 2×6+2×(2×0.5)+1×0.5 | 2×6 + 2×(2×0.5) + 1×0.5 mm² | Class 5 Cu + Cu screen + Q braid | 18.4 | 510 | 4.6 | 185 | |
| L-2YYQY 2×10+2×(2×0.75)+1×0.75 | 2×10 + 2×(2×0.75) + 1×0.75 mm² | Class 5 Cu + Cu screen + Q braid | 21.2 | 690 | 6.2 | 215 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 2×4 + 2×(2×0.5) + 1×0.5 mm² | 4.95 | 300/500 V / 32 A + Ex-i | −30…+70 °C |
| 2×6 + 2×(2×0.5) + 1×0.5 mm² | 3.30 | 300/500 V / 41 A + Ex-i | −30…+70 °C |
| 2×10 + 2×(2×0.75) + 1×0.75 mm² | 1.91 | 300/500 V / 57 A + Ex-i | −30…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60079-14 / PN-G-91006) | Electrical parameters and outer diameter within IEC 60079-14 / PN-G-91006 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60079-14 / PN-G-91006) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60079-14 / PN-G-91006) | Verified structural and dielectric integrity across −30…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.