Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Aquaculture Winch Subsea Feeding Camera Cable (Blue TPU / Black Reinforced RG59 Hybrid & Green PUR Cat5e PoE) & High-Pressure Net Cleaner Breakout Cable (LH-1250-023 to LH-1250-026) (IEEE 802.3at PoE+ / RG59, 300/500 V, -25 °C to +75 °C).
Typical values for this cable type, based on IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner — confirmed in the datasheet and quotation for your order.
Application fit
Aquaculture Winch Subsea Feeding Camera Cable (Blue TPU / Black Reinforced RG59 Hybrid & Green PUR Cat5e PoE) & High-Pressure Net Cleaner Breakout Cable (LH-1250-023 to LH-1250-026) (IEEE 802.3at PoE+ / RG59, 300/500 V, -25 °C to +75 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: LH-1250 CABLE (IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner) featuring center 75 ω rg59 video coax (or cat5e poe), shielded rs-485 control & sensor pairs and anti-biofouling blue/black/green tpu sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center 75 Ω RG59 Video Coax (or Cat5e PoE) | 75-ohm RG59 coaxial video unit (or 4-pair Cat5e PoE+ in Green PoE+ camera cable) |
| 2 | Shielded RS-485 Control & Sensor Pairs | Two foil-screened RS-485 pairs for pan/tilt camera, depth and dissolved-oxygen sensors |
| 3 | DC Power & LED Lighting Cores (24–75 V DC) | Four stranded tinned copper cores powering subsea camera and 4×LED floodlights |
| 4 | Overall Shield & Aramid Winch Braid | Tinned copper EMI braid + high-tenacity aramid reinforcement for motorized winch reeling |
| 5 | Anti-Biofouling Blue/Black/Green TPU Sheath | Seawater-, UV- and mussel-resistant thermoplastic polyurethane jacket (Ø 10.8–12.6 mm) |
Built to IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner with center 75 ω rg59 video coax (or cat5e poe) and anti-biofouling blue/black/green tpu sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LH-1250 CABLE Construction Schedule (−25…+75 °C) | |||||||
| LH-1250 CABLE Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| LH-1250 CABLE Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| LH-1250 CABLE Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 300/500 V (45–100 Ω data) | −25…+75 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 300/500 V (45–100 Ω data) | −25…+75 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 300/500 V (High-Power Hybrid) | −25…+75 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner) | Zero dielectric breakdown and verified insulation resistance for 300/500 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEEE 802.3at PoE+ / Subsea Aquaculture Camera & Net Cleaner) | Verified submersion integrity, tensile load and thermal stability across −25…+75 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.