Switchgear & control cabinet wiring
Transmits low-voltage sensor and gate signals onto a deck floating at 5 kVAC or 15 kVDC relative to earth.
Product
HSC-5-7X2SVA-2 5 kVAC / 15 kVDC floating-potential control cable isolating a 7 × AWG 26 low-voltage control bundle inside an inner floating screen, stress-controlled XLPE high-voltage barrier, outer grounded EMC copper braid and a red PVC jacket.
Typical values for this cable type, based on DIN 47100 / IEC 60502 — confirmed in the datasheet and quotation for your order.
Application fit
HSC-5-7X2SVA-2 5 kVAC / 15 kVDC floating-potential control cable isolating a 7 × AWG 26 low-voltage control bundle inside an inner floating screen, stress-controlled XLPE high-voltage barrier, outer grounded EMC copper braid and a red PVC jacket.
Transmits low-voltage sensor and gate signals onto a deck floating at 5 kVAC or 15 kVDC relative to earth.
Inner/outer semiconductive PE + XLPE HV barrier prevents partial discharge between Screen I and Screen II.
Dual concentric tinned copper braids shield sensitive control signals against dV/dt switching transients.
High-voltage potential-isolation control cable for fixed cabinets and test cells; not for crane reels.
L-2YYQYConstruction
Shown: HSC-5-7X2SVA-2 (DIN 47100 / IEC 60502) featuring control bundle (7xawg 26), inner screen i (floating hv) and outer sheath (-2 red) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Control Bundle (7xAWG 26) | Seven 7 x 0.16 mm (0.14 mm², AWG 26) stranded tinned copper control cores with DIN 47100 polypropylene (PP) insulation (300 V core-to-screen I)DIN 47100 / IEC 60502 |
| 2 | Inner Screen I (Floating HV) | Polyester separator tape and inner tinned copper wire braid screen I operating at floating high-voltage potentialDIN 47100 / IEC 60502 |
| 3 | HV Stress-Controlled Barrier | Co-extruded inner semiconductive PE layer, thick crosslinked polyethylene (XLPE / PE-X) 5 kVAC / 15 kVDC barrier, and outer semicon PEDIN 47100 / IEC 60502 |
| 4 | Outer Screen II (Earth) | Outer tinned copper wire braid shield II referenced to earth potential for personnel safety and EMC containmentDIN 47100 / IEC 60502 |
| 5 | Outer Sheath (-2 Red) | Red silk-mat polyvinyl chloride (PVC) outer sheath (OD 11.4 mm) identifying high-voltage floating-potential circuitsDIN 47100 / IEC 60502 |
Built to DIN 47100 / IEC 60502 with control bundle (7xawg 26) and outer sheath (-2 red)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to DIN 47100 / IEC 60502 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HSC-5-7X2SVA-2 Construction Schedule (−30…+80 °C) | |||||||
| HSC-5-4X2SVA-2 (4×AWG 26, 15 kVDC) | 4 × AWG 26 (0.14 mm²) | 7×0.16 mm tinned Cu + 2×screen | 10.2 | 148 | 0.4 | 102 | |
| HSC-5-7X2SVA-2 (7×AWG 26, 15 kVDC) | 7 × AWG 26 (0.14 mm²) | 7×0.16 mm tinned Cu + 2×screen | 11.4 | 185 | 0.6 | 114 | |
| HSC-5-12X2SVA-2 (12×AWG 26, 15 kVDC) | 12 × AWG 26 (0.14 mm²) | 7×0.16 mm tinned Cu + 2×screen | 13.2 | 245 | 0.9 | 132 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 4 × AWG 26 (300 V / 15 kVDC) | 138.00 | 5 kVAC / 15 kVDC isolation | −30…+80 °C |
| 7 × AWG 26 (300 V / 15 kVDC) | 138.00 | 5 kVAC / 15 kVDC isolation | −30…+80 °C |
| 12 × AWG 26 (300 V / 15 kVDC) | 138.00 | 5 kVAC / 15 kVDC isolation | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (DIN 47100 / IEC 60502) | Electrical parameters and outer diameter within DIN 47100 / IEC 60502 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (DIN 47100 / IEC 60502) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (DIN 47100 / IEC 60502) | Verified structural and dielectric integrity across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking