Reeling cableNF M 82-375 / VDE 0250-812U0/U 0.6/1 kV (1.1 kV mining)Tout-Terrain Dual PCP

6-CHCU-TT Mining Reeling Cable0.6/1 kV (1.1 kV mining) Tout-Terrain EPR/PCP reeling cable for scooptrams and jumbos

Built to NF M 82-375 and DIN VDE 0250-812 for underground scooptrams, shuttle cars, drill jumbos and quarry reeling drums up to 80 m/min, with Class 5 tinned copper conductors, 3GI3 EPR insulation and reinforced dual 5GM5.

Anti-torsion braid
Outdoor & humid
Oil-resistant
Flame-retardant
Order designation
6-CHCU-TT 3×35+16
Outer Ø max
36.0 mm
Weight ≈
2,210 kg/km
Min. bend R
216 mm
Perm. pull
1,575 N
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
1.1 kV mining · max. AC 0.7/1.2 kV
Reeling speed
80 m/min
max. on shuttle car & loader drums
Tensile load
15–20 N/mm²
15 N/mm² perm. · 20 N/mm² dynamic
Bending radius
5–6 × OD
5 × OD moving · 6 × OD reeling
Temperature
−25…+80 °C
flexing · +90 °C max. conductor
Sizes
18
4 × 4 to 3 × 150 + 70 mm²

Typical values for this cable type, based on NF M 82-375 / DIN VDE 0250-812 — confirmed in the datasheet and quotation for your order.

Application fit

Is 6-CHCU-TT right for your machine?

6-CHCU-TT (Tout-Terrain) is designed for rugged mining drum reeling up to 80 m/min and heavy roadway trailing where impact, abrasion and oil resistance are paramount.

Cylindrical / multi-layer drum

Suitable

Cylindrical and monospiral drum reeling on underground scooptrams, shuttle cars and drill jumbos up to 80 m/min.

Motorised monospiral reel

Suitable

Horizontal mobile reeling on quarry stackers, mobile crushers and underground haulage units.

Mine roadway & tunnel wall hangers

Suitable

Tout-Terrain vulcanised dual 5GM5 polychloroprene jacket withstands rough mine floors and wet headings.

Trailing & towing

Suitable

Heavy trailing feeder for open-pit drills, dewatering pumps and mobile mining substations.

Typical machinesUnderground scooptrams & shuttle carsMining drill jumbos & boltersQuarry crushers & mobile conveyorsTunnel excavation & dewateringPotash, coal & hard-rock mines

Construction

Layer by layer

Shown: 6-CHCU-TT 4-core / 3P+E+Pilot construction with Class 5 tinned copper conductors, 3GI3 EPR insulation, vulcanised inner PCP sheath, textile reinforcement and heavy-duty 5GM5 outer sheath.

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible tinned copper conductorElectrolytic tinned copper, finely stranded Class 5IEC 60228 Class 5 / NF C 32-013
2Core insulationCross-linked ethylene-propylene rubber (EPR) compound type 3GI3NF M 82-375 / DIN VDE 0207-20 · 90 °C continuous / 250 °C short-circuit
3Core assembly & optional pilot coresShort-lay core stranding around elastomeric centre filler, with green-yellow earth and optional 2.5 mm² pilot coresBalanced core geometry for multi-layer mining drum winding
4Inner sheathVulcanised polychloroprene (PCP) compound type 5GM3Pressure-extruded inner bedding locking the core lay
5Textile mechanical reinforcementHigh-strength synthetic textile reinforcement embedded between inner and outer sheathsEnhances radial impact resistance and ±50 °/m torsional stability
6Outer sheath (Tout-Terrain)Heavy-duty polychloroprene (PCP) compound type 5GM5 / EM2, yellow or blackNF M 82-375 · tear, cut and abrasion resistant · EN 60811-404 oil · IEC 60332-1-2 flame

6-CHCU-TT 4G / 5G

4-core (3P+E) and 5-core (3P+N+E) symmetrical power and reeling configurations (4 to 35 mm²)

6-CHCU-TT 3P+E (+ Pilots)

3 phase cores + reduced protective earth + optional 1–3 × 2.5 mm² pilot cores (16 to 150 mm²)

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NF M 82-375 / DIN VDE 0250-812. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
0.6/1 kV (up to 1.1 kV mining service)
Max. operating voltage AC
0.7/1.2 kV
Max. operating voltage DC
0.9/1.8 kV
AC test voltage (5 min)
3.5 kV AC (power) · 2.0 kV AC (pilot)
Current rating basis
DIN VDE 0298-4 / NF C 15-100 (30 °C in air)

Thermal

Temperature, flexing
−25 to +80 °C
Temperature, fixed
−40 to +80 °C
Max. conductor temperature
+90 °C
Short-circuit temperature (5 s)
+250 °C

Mechanical

Min. bending radius, moving
5 × OD trailing · 6 × OD drum reeling
Min. bending radius, fixed
4 × OD
Max. reeling speed
80 m/min
Max. tensile load
15 N/mm² perm. · 20 N/mm² dynamic
Torsional stress
± 50 °/m

Resistance

Oil resistance
EN 60811-404 (mineral & hydraulic oils)
Flame retardance
IEC 60332-1-2 / NF C 32-070 C2
Abrasion & impact resistance
Tout-Terrain 5GM5 polychloroprene sheath
Water & mine dampness
AD7 / HD 22.16 submersible in mine water

Reference standards

Construction standard
NF M 82-375 / DIN VDE 0250-812
Conductor standard
IEC 60228 Class 5 / NF C 32-013
Compound designation
3GI3 EPR · 5GM3 inner · 5GM5 outer

Identification

Outer sheath colour
Black or yellow (high-visibility mining)
Core identification
HD 308 S2 + green-yellow earth
Customs tariff (HS)
8544.49

Sizes

18 standard sizes (0.6/1 kV – 1.1 kV mining)

Typical dimensions for 6-CHCU-TT across 4-core symmetrical, 3P+E reduced-earth and pilot-monitored configurations.

Dimensions & weights
Order designationCores × mm²Phase AWG ≈Outer Ø max
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
mm
Perm. pull
N
Enquiry
4G / 5G symmetrical power (4–35 mm²)
6-CHCU-TT 4G44 × 41219.0154495114240
6-CHCU-TT 4G64 × 61020.8230635125360
6-CHCU-TT 4G104 × 10824.8384985149600
6-CHCU-TT 4G164 × 16628.86141,340173960
6-CHCU-TT 4G254 × 25434.89601,9802091,500
6-CHCU-TT 4G354 × 35238.21,3442,5802292,100
6-CHCU-TT 5G165 × 16631.27681,6501871,200
3 × Phase + Reduced Earth (16–150 mm²)
6-CHCU-TT 3×25+163 × 25 + 1 × 16432.88741,7901971,125
6-CHCU-TT 3×35+163 × 35 + 1 × 16236.01,1622,2102161,575
6-CHCU-TT 3×50+253 × 50 + 1 × 25141.21,6803,0102472,250
6-CHCU-TT 3×70+353 × 70 + 1 × 352/046.42,3523,9902783,150
6-CHCU-TT 3×95+503 × 95 + 1 × 503/052.63,2165,2903164,275
6-CHCU-TT 3×120+703 × 120 + 1 × 704/057.84,1286,5403475,400
6-CHCU-TT 3×150+703 × 150 + 1 × 70300 kcmil62.44,9927,7403746,750
3 × Phase + Earth + Pilot (16–95 mm²)
6-CHCU-TT 3×25+16+1×2.53 × 25 + 16 + 1 × 2.5433.88981,8802031,125
6-CHCU-TT 3×35+16+1×2.53 × 35 + 16 + 1 × 2.5237.01,1862,3102221,575
6-CHCU-TT 3×50+25+1×2.53 × 50 + 25 + 1 × 2.5142.21,7043,1302532,250
6-CHCU-TT 3×95+50+1×2.53 × 95 + 50 + 1 × 2.53/053.63,2405,4203224,275
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • TT = Tout-Terrain heavy-duty dual polychloroprene (5GM3 / 5GM5) sheath system for underground and surface mining.
  • For severe torsional reeling over multi-plane diversion rollers (> ±50 °/m), specify 6-CHCU TTAR.

Reel check

Will it fit your machine?

A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.

Check results

Drum core 630 mm ≥ 432 mmBending radius OK (6 × OD 36.0 mm)
60 m/min ≤ 80 m/minWithin the rated travel speed
Minimum bending radius
216 mm
Min. drum core diameter
≈ 432 mm
Cable weight on drum
265.2 kg
Copper content
139.4 kg
Indicative only: based on the datasheet outer diameter and 6 × OD bending radius. Current derating for wound layers per DIN VDE 0298-4 is assessed separately.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC voltage test on cores3.5 kV AC for 5 min (power) · 2.0 kV AC (pilot)Every manufactured length
Conductor DC resistanceIEC 60228 Class 5 tinned copperEvery length
Sample tests
5GM5 outer sheath oil & mechanical ageingEN 60811-404 oil immersion · tear & abrasion checkPer batch
Flame propagationIEC 60332-1-2 / NF C 32-070 C2Per batch
Tout-Terrain impact, crushing & drum flexing testNF M 82-375 / DIN VDE 0250-812 mechanical qualificationType qualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NF M 82-375 / VDE 0250-812CE · LVDRoHS · REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 6-CHCU-TT 0.6/1 kV (1.1 kV) 3x35+16 NF M 82-375 · [year] · [metre mark]
Delivery form
Heavy export timber or steel mining drums, cut-to-length
Packaging
ISPM-15 heat-treated lagged drums with sealed moisture-proof ends

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What is 6-CHCU-TT used for in underground and surface mines?
6-CHCU-TT (Tout-Terrain) is a 0.6/1 kV (up to 1.1 kV mining service) heavy-duty elastomeric reeling and trailing cable built to NF M 82-375 and DIN VDE 0250-812. It feeds underground scooptrams, shuttle cars, drill jumbos, roadheaders and quarry crushers operating on cylindrical or monospiral cable drums up to 80 m/min and over rough blasted rock roadways.
How does 6-CHCU-TT differ from 6-CHCU TTAR?
Both cables share Class 5 tinned copper conductors, 3GI3 EPR core insulation and a vulcanised dual 5GM3/5GM5 polychloroprene sheath system. 6-CHCU-TT uses textile reinforcement suited to standard drum reeling (up to 80 m/min, 15–20 N/mm² pull, ±50 °/m twist), whereas 6-CHCU TTAR adds a high-tenacity Anti-Rotation (AR) braid for higher dynamic pull (20–25 N/mm²) and ±100 °/m torsion.
Why are tinned copper conductors standard on 6-CHCU-TT?
Tinning each fine Class 5 copper wire prevents sulfur cross-reaction during high-pressure vulcanisation of the 3GI3 EPR rubber insulation and protects conductor terminations against oxidation and corrosion in hot, humid, sulfur-bearing underground mine atmospheres, drilling emulsions and saline tunnel water.
What minimum drum barrel diameter is required for 6-CHCU-TT?
For motorised drum reeling, maintain a minimum bending radius of 6 × OD (meaning a minimum drum barrel diameter of 12 × OD), and at least 5 × OD on free-moving trailing loops. When winding multiple layers onto a shuttle car or scooptram reel, apply DIN VDE 0298-4 layer derating factors to prevent overheating.

Request a quote

Get an engineering quote for 6-CHCU-TT

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

6-CHCU-TT Mining Reeling Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote