Mine roadway & tunnel wall hangers
Individual tinned copper braid over every core prevents inter-core crosstalk and fault propagation in mine control loops.
Product
YnHKGSLY 300/500 V underground mining control cable featuring Class 5 flexible copper conductors, numbered black PVC core insulation (plus green/yellow PE), individual tinned copper wire braid screens over every core and a grey flame-retardant Yn PVC jacket.
Typical values for this cable type, based on PN-G-91006 / IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
YnHKGSLY 300/500 V underground mining control cable featuring Class 5 flexible copper conductors, numbered black PVC core insulation (plus green/yellow PE), individual tinned copper wire braid screens over every core and a grey flame-retardant Yn PVC jacket.
Individual tinned copper braid over every core prevents inter-core crosstalk and fault propagation in mine control loops.
Grey flame-retardant Yn PVC jacket meets underground mine gallery fire-propagation requirements.
Class 5 flexible copper conductors tolerate occasional repositioning on mining machinery skids.
PVC control cable for fixed or semi-fixed underground routing; not for continuous dynamic reeling.
HSC-5-7X2SVA-2Construction
Shown: YnHKGSLY (PN-G-91006 / IEC 60332-1-2) featuring control conductors (7g1.5 mm²), pvc core insulation and flame-retardant outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Control Conductors (7G1.5 mm²) | Seven 1.5 mm² Class 5 flexible plain annealed copper conductors for underground mining automation and signallingPN-G-91006 / IEC 60332-1-2 |
| 2 | PVC Core Insulation | Extruded polyvinyl chloride (PVC) primary insulation with white-numbered black control cores and one green/yellow protective earth corePN-G-91006 / IEC 60332-1-2 |
| 3 | Individual Core Braid Screens | Dedicated tinned copper wire braid electromagnetic screen applied directly over every individual insulated core to prevent inter-core crosstalkPN-G-91006 / IEC 60332-1-2 |
| 4 | Flame-Retardant Outer Sheath | Grey mining-grade flame-retardant polyvinyl chloride (Yn PVC) outer sheath meeting underground mine fire propagation standardsPN-G-91006 / IEC 60332-1-2 |
Built to PN-G-91006 / IEC 60332-1-2 with control conductors (7g1.5 mm²) and flame-retardant outer sheath
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to PN-G-91006 / IEC 60332-1-2 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| YnHKGSLY Construction Schedule (−30…+70 °C) | |||||||
| YnHKGSLY 5G1.5 mm² Per-Core Screened | 5G1.5 mm² | Class 5 Cu + per-core Cu braid | 13.8 | 285 | 1.1 | 115 | |
| YnHKGSLY 7G1.5 mm² Per-Core Screened | 7G1.5 mm² | Class 5 Cu + per-core Cu braid | 15.2 | 370 | 1.5 | 125 | |
| YnHKGSLY 10G1.5 mm² Per-Core Screened | 10G1.5 mm² | Class 5 Cu + per-core Cu braid | 18.6 | 510 | 2.2 | 155 | |
| YnHKGSLY 12G1.5 mm² Per-Core Screened | 12G1.5 mm² | Class 5 Cu + per-core Cu braid | 19.4 | 585 | 2.6 | 160 | |
| YnHKGSLY 7G2.5 mm² Per-Core Screened | 7G2.5 mm² | Class 5 Cu + per-core Cu braid | 17.6 | 520 | 2.5 | 145 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 5G1.5 mm² (Per-Core Screened) | 13.30 | 300/500 V / 16 A | −30…+70 °C |
| 7G1.5 mm² (Per-Core Screened) | 13.30 | 300/500 V / 14 A | −30…+70 °C |
| 10G1.5 mm² (Per-Core Screened) | 13.30 | 300/500 V / 12 A | −30…+70 °C |
| 12G1.5 mm² (Per-Core Screened) | 13.30 | 300/500 V / 11 A | −30…+70 °C |
| 7G2.5 mm² (Per-Core Screened) | 7.98 | 300/500 V / 20 A | −30…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (PN-G-91006 / IEC 60332-1-2) | Electrical parameters and outer diameter within PN-G-91006 / IEC 60332-1-2 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (PN-G-91006 / IEC 60332-1-2) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (PN-G-91006 / IEC 60332-1-2) | Verified structural and dielectric integrity across −30…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.