Galerie minière et crochets de paroi
Individual étamé cuivre braid over every core prevents inter-core crosstalk et fault propagation in mine control loops.
Produit
YnHKGSLY 300/500 V underground mining control cable featuring Class 5 flexible cuivre conducteurs, numbered black PVC core isolation (plus green/yellow PE), individual étamé cuivre wire braid screens over every core et a grey flame-retardant Yn PVC jacket.
Valeurs types pour ce type de câble, basés sur PN-G-91006 / IEC 60332-1-2 (spécification technique) — confirmées dans la fiche technique et le devis de votre commande.
Applications
YnHKGSLY 300/500 V underground mining control cable featuring Class 5 flexible cuivre conducteurs, numbered black PVC core isolation (plus green/yellow PE), individual étamé cuivre wire braid screens over every core et a grey flame-retardant Yn PVC jacket.
Individual étamé cuivre braid over every core prevents inter-core crosstalk et fault propagation in mine control loops.
Grey flame-retardant Yn PVC jacket meets underground mine gallery fire-propagation requirements. (spécification technique)
Class 5 flexible cuivre conducteurs tolerate occasional repositioning on mining machinery skids.
PVC control cable pour fixed or semi-fixed underground routing; not pour continuous dynamic reeling.
HSC-5-7X2SVA-2 (spécification technique)Construction
Shown: YnHKGSLY (PN-G-91006 / IEC 60332-1-2) featuring control conducteurs (7g1.5 mm²), pvc core isolation et flame-retardant gaine extérieure (4-layer construction).
| # | Couche | Matériau et référence |
|---|---|---|
| 1 | Control Conductors (7G1.5 mm²) (spécification technique) | Seven 1.5 mm² Class 5 flexible plain annealed cuivre conducteurs pour underground mining automation et signallingPN-G-91006 / IEC 60332-1-2 (spécification technique) |
| 2 | Isolation des conducteurs en PVC | Extruded polyvinyl chloride (PVC) primary isolation avec white-numbered black control cores et one green/yellow protective earth corePN-G-91006 / IEC 60332-1-2 (spécification technique) |
| 3 | Individual Core Braid Screens (spécification technique) | Dedicated étamé cuivre wire braid electromagnetic screen applied directly over every individual insulated core à prevent inter-core crosstalkPN-G-91006 / IEC 60332-1-2 (spécification technique) |
| 4 | Flame-Retardant Gaine extérieure | Grey mining-grade flame-retardant polyvinyl chloride (Yn PVC) gaine extérieure meeting underground mine fire propagation standardsPN-G-91006 / IEC 60332-1-2 (spécification technique) |
Built à PN-G-91006 / IEC 60332-1-2 avec control conducteurs (7g1.5 mm²) et flame-retardant gaine extérieure
Available in custom drum lengths, core counts or factory-terminated assemblies (spécification technique)
Supplied avec EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Données techniques
Dimensions
Manufactured à PN-G-91006 / IEC 60332-1-2 pour de service intensif industrial et specialty engineering systems.
| Désignation de commande | Configuration | Âme / câblage | Ø extérieur ≈ mm | Masse ≈ kg/km | Tensile load kN ≈ (spécification technique) | Rayon min. R mm | Demande |
|---|---|---|---|---|---|---|---|
| YnHKGSLY Construction Schedule (−30…+70 °C) (spécification technique) | |||||||
| YnHKGSLY 5G1.5 mm² Per-Core Screened | 5G1.5 mm² | Class 5 Cu + per-core Cu braid (spécification technique) | 13.8 | 285 | 1.1 | 115 | |
| YnHKGSLY 7G1.5 mm² Per-Core Screened | 7G1.5 mm² | Class 5 Cu + per-core Cu braid (spécification technique) | 15.2 | 370 | 1.5 | 125 | |
| YnHKGSLY 10G1.5 mm² Per-Core Screened | 10G1.5 mm² (spécification technique) | Class 5 Cu + per-core Cu braid (spécification technique) | 18.6 | 510 | 2.2 | 155 | |
| YnHKGSLY 12G1.5 mm² Per-Core Screened | 12G1.5 mm² | Class 5 Cu + per-core Cu braid (spécification technique) | 19.4 | 585 | 2.6 | 160 | |
| YnHKGSLY 7G2.5 mm² Per-Core Screened | 7G2.5 mm² | Class 5 Cu + per-core Cu braid (spécification technique) | 17.6 | 520 | 2.5 | 145 | |
| Configuration | R₂₀ DC max. / Attén. Ω/km ou dB/km | Rating / Capacity (spécification technique) | Temp. de service |
|---|---|---|---|
| 5G1.5 mm² (Per-Core Blindé) | 13.30 | 300/500 V / 16 A (spécification technique) | −30…+70 °C |
| 7G1.5 mm² (Per-Core Blindé) | 13.30 | 300/500 V / 14 A (spécification technique) | −30…+70 °C |
| 10G1.5 mm² (Per-Core Blindé) | 13.30 | 300/500 V / 12 A (spécification technique) | −30…+70 °C |
| 12G1.5 mm² (Per-Core Blindé) | 13.30 | 300/500 V / 11 A (spécification technique) | −30…+70 °C |
| 7G2.5 mm² (Per-Core Blindé) | 7.98 | 300/500 V / 20 A (spécification technique) | −30…+70 °C |
Qualité et homologations
Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.
| Essais et contrôle | Valeur d’essai / référence | Fréquence |
|---|---|---|
| Essais individuels | ||
| Conductor resistance & dimensional verification (PN-G-91006 / IEC 60332-1-2) (spécification technique) | Electrical parameters et outer diameter within PN-G-91006 / IEC 60332-1-2 tolerances | Every manufactured drum / length (spécification technique) |
| High-voltage dielectric & isolation resistance test (PN-G-91006 / IEC 60332-1-2) | Zero dielectric breakdown et verified isolation resistance over full length | Every manufactured drum / length (spécification technique) |
| Essais sur prélèvements | ||
| Thermal ageing, mechanical flexing & environmental qualification (PN-G-91006 / IEC 60332-1-2) (spécification technique) | Verified structural et dielectric integrity across −30…+70 °C | Qualification de type et audit périodique de lot |
Marquage et livraison
Marquage de la gaine
Documents techniques
FAQ
Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.
Demander un devis
Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.
Utilisez + Ajouter à côté d’une dimension ou configuration.
Ajoutez ici vos conditions de service pour les inclure dans votre demande.