Mine roadway & tunnel wall hangers
Individual copper braid plus dedicated PVC sub-jacket over each pair provides electrical and mechanical pair isolation.
Product
YnHTKGX 150/250 V mining telecom and instrumentation pair cable combining a central 1.0 mm² green/yellow protective conductor with 0.8 mm PE twisted pairs, each with a 0.8 mm drain wire, copper braid screen and PVC sub-jacket under a grey Yn PVC sheath.
Typical values for this cable type, based on PN-G-91006 / IEC 60079-14 — confirmed in the datasheet and quotation for your order.
Application fit
YnHTKGX 150/250 V mining telecom and instrumentation pair cable combining a central 1.0 mm² green/yellow protective conductor with 0.8 mm PE twisted pairs, each with a 0.8 mm drain wire, copper braid screen and PVC sub-jacket under a grey Yn PVC sheath.
Individual copper braid plus dedicated PVC sub-jacket over each pair provides electrical and mechanical pair isolation.
Central 1.0 mm² green/yellow tinned copper protective conductor provides continuous earth reference along mine drifts.
Low-loss polyethylene (PE) pair dielectric supports long-distance underground RS-485, methanometry and intercom links.
Solid 0.8 mm Class 1 copper telecom conductors are designed for fixed roadway brackets, not dynamic reeling.
HSC-0.25-8Q1SFA-6Construction
Shown: YnHTKGX (PN-G-91006 / IEC 60079-14) featuring central protective conductor, telecom pairs (4x2x0.8 mm) and overall outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Protective Conductor | Central 1.0 mm² solid tinned copper protective earth conductor insulated with green/yellow PVC at the cable axisPN-G-91006 / IEC 60079-14 |
| 2 | Telecom Pairs (4x2x0.8 mm) | Four twisted telecommunication pairs of 0.8 mm Class 1 solid bare copper conductors with low-loss red and blue polyethylene (PE) insulationPN-G-91006 / IEC 60079-14 |
| 3 | Per-Pair Drain & Copper Braid | Longitudinal 0.8 mm tinned copper drain wire and individual bare copper wire braid screen (>= 75% coverage) over each pairPN-G-91006 / IEC 60079-14 |
| 4 | Per-Pair Individual PVC Jacket | Extruded individual polyvinyl chloride (PVC) sub-jacket isolating each screened pair mechanically and electricallyPN-G-91006 / IEC 60079-14 |
| 5 | Overall Outer Sheath | Heavy-duty grey flame-retardant mining polyvinyl chloride (Yn PVC) overall outer sheathPN-G-91006 / IEC 60079-14 |
Built to PN-G-91006 / IEC 60079-14 with central protective conductor and overall outer sheath
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to PN-G-91006 / IEC 60079-14 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| YnHTKGX Construction Schedule (−30…+70 °C) | |||||||
| YnHTKGX 2×2×0.8 + 1.0 mm² | 2×2×0.8 mm + 1×1.0 mm² PE | Solid Cu + per-pair braid & jacket | 12.6 | 195 | 0.9 | 126 | |
| YnHTKGX 4×2×0.8 + 1.0 mm² | 4×2×0.8 mm + 1×1.0 mm² PE | Solid Cu + per-pair braid & jacket | 15.8 | 325 | 1.6 | 158 | |
| YnHTKGX 7×2×0.8 + 1.0 mm² | 7×2×0.8 mm + 1×1.0 mm² PE | Solid Cu + per-pair braid & jacket | 19.4 | 510 | 2.6 | 194 | |
| YnHTKGX 10×2×0.8 + 1.0 mm² | 10×2×0.8 mm + 1×1.0 mm² PE | Solid Cu + per-pair braid & jacket | 23.6 | 715 | 3.6 | 236 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 2×2×0.8 + 1.0 mm² | 36.60 | 150/250 V / ≤75 nF/km | −30…+70 °C |
| 4×2×0.8 + 1.0 mm² | 36.60 | 150/250 V / ≤75 nF/km | −30…+70 °C |
| 7×2×0.8 + 1.0 mm² | 36.60 | 150/250 V / ≤75 nF/km | −30…+70 °C |
| 10×2×0.8 + 1.0 mm² | 36.60 | 150/250 V / ≤75 nF/km | −30…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (PN-G-91006 / IEC 60079-14) | Electrical parameters and outer diameter within PN-G-91006 / IEC 60079-14 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (PN-G-91006 / IEC 60079-14) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (PN-G-91006 / IEC 60079-14) | Verified structural and dielectric integrity across −30…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.