Contact

VFD-TGK-FLX 1000 V Symmetrical Flex VFD CableFlexible tri-ground symmetrical 1000 V TC-ER / WTTC VFD motor cable

VFD-TGK-FLX Symmetrical 1000 V combines Class 5/K flexible bare copper phases with three symmetrical interstitial insulated grounds, thermoset XLPE insulation, and dual foil/braid screening for flexible industrial VFD runs.

Low-EMC design
EMC screen
Flame-retardant
Outdoor & humid
Order designation
VFD-TGK-FLX 1000V 3×4 AWG + 3×12 AWG
Outer Ø
24.0 mm
Max. R20
0.892 Ω/km
Weight
1,322 kg/km
Min. bend R
192 mm
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
AC test voltage 4 kV AC
EMC screening
Foil + TCWB
Low transfer impedance EMC shield
Temp. (fixed)
-40°C…+90°C
Flexing: -25 °C to +90 °C
Min. bend radius
8 × OD
Continuous drag-chain flexing
Conductor
Bare Cu · Cl.K
ASTM B172 / B8 copper
Size range
14 AWG–500 kcmil
12 standard configurations

Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4 — confirmed in the datasheet and quotation for your order.

Application fit

Is VFD-TGK-FLX 1000V right for your machine?

VFD-TGK-FLX Symmetrical 1000 V combines Class 5/K flexible bare copper phases with three symmetrical interstitial insulated grounds, thermoset XLPE insulation, and dual foil/braid screening for flexible industrial VFD runs.

VFD inverter to AC motor screened feeder

Suitable

Low-capacitance 1000 V XLPE/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.

Energy chain / drag chain

Suitable

Extra-flexible 1000 V XLPE/TPE stranding and 8×D bend rating endure continuous energy-chain flexing.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 1000 V XLPE/TPE construction routes cleanly along factory automation trays, machine frames, and production lines.

Process pump & compressor skid

Suitable

Durable 1000 V XLPE/TPE construction powers industrial process pumps, boosters, and compressor skids under continuous plant duty.

Motorised monospiral reel

Not suitable

1000 V XLPE/TPE build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.

Use RG / RG-D (N)SHTOEU-J

Immersion & wet locations

Not suitable

1000 V XLPE/TPE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableVariable frequency drive (VFD) motor baysIndustrial pumps, fans & compressor skidsProcess plants, oil & gas & HVAC systemsHeavy manufacturing & plant MCC feeders

Construction

Layer by layer

Representative construction of VFD-TGK-FLX 1000V: bare copper conductors, 1000 V thermoset XLPE (symmetrical 3+3), 100% Al/polyester foil + ≥ 85% tinned copper braid, and Black oil- & UV-resistant flexible TPE/PVC outer sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 Class K flexible bare annealed copperASTM B172 Class K / UL 1277
2Core insulation1000 V thermoset XLPE (symmetrical 3+3)UL 1277 Type TC-ER
3Core assembly & separatorConcentric cabled assembly with low-friction fleece or polyester binder tapeUL 1277 Type TC-ER
4EMC metallic screen100% Al/polyester foil + ≥ 85% tinned copper braidEMC ≥ 85% / 100% foil
5Outer sheathBlack oil- & UV-resistant flexible TPE/PVC outer sheathUL Oil Res I/II

VFD-TGK-FLX 1000V 3C + 3G Symmetrical

Three numbered black XLPE phase conductors with three symmetrically laid interstitial grounds under EMC shield.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
1000 V
AC test voltage
4 kV AC / 5 min
Conductor class
ASTM B172 Class K bare Cu
EMC screen
100% Al/polyester foil + ≥ 85% tinned
Insulation resistance
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +90 °C
Temp. range (flexing)
-25 °C to +90 °C
Short-circuit temp.
+250 °C (5 s)
Min. bending radius
8 × OD (flexing)

Resistance

Flame retardance
UL Oil Res I/II
Oil & chemical perf.
IEEE 1202 / FT4 Flame
Environmental / EMC
Sunlight Resistant
Outer sheath
Black oil- & UV-resistant flexible

Sizes

3C + 3G Symmetrical (AWG/kcmil)
Cores ×
AWG/kcmil
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
3×14 AWG + 3×18 AWG12.39.07011424498
3×12 AWG + 3×16 AWG13.35.710164325106
3×10 AWG + 3×14 AWG14.73.590243451118
3×8 AWG + 3×14 AWG18.12.260338646145
3×6 AWG + 3×12 AWG20.21.420513922162
3×4 AWG + 3×12 AWG24.00.8927401,322192
3×2 AWG + 3×10 AWG28.50.5611,1471,996228
3×1/0 AWG + 3×6 AWG32.90.3531,9263,169263
3×2/0 AWG + 3×6 AWG35.50.2802,3153,782284
3×4/0 AWG + 3×4 AWG42.40.1763,6435,832339
3×350 kcmil + 3×2 AWG51.90.1075,9359,348415
3×500 kcmil + 3×2 AWG59.40.0758,04412,590475
  • Max. conductor DC resistance R20 at 20 °C per ASTM B172 / B8 (bare copper).
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric test4 kV AC for 5 min without breakdownEvery manufactured drum
Conductor DC resistance testPer ASTM B172 / B8 at 20 °CEvery drum length
Sample tests
EMC screen coverage & insulation checkFoil + TCWB continuity & wall thicknessPer production lot
Flame & environmental qualificationUL Oil Res I/II · IEEE 1202 / FT4 FlameType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 1277 Type TC-ERUL 2277 Type WTTCCSA AWM I/II A/B FT4EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

VFD-TGK-FLX 1000V 1000 V TEBAOFLEX.COM [UL 1277 Type TC-ER] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-21
Updated
2026-11-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes VFD-TGK-FLX 1000V suitable for 1000 V industrial installations?
VFD-TGK-FLX 1000V combines bare copper conductors, 1000 V thermoset XLPE (symmetrical 3+3), and 100% Al/polyester foil + ≥ 85% tinned copper braid inside a Black oil- & UV-resistant flexible TPE/PVC outer sheath. Tri-ground symmetrical flexible construction balances ground currents on portable and tray-routed VFD drives.
Can VFD-TGK-FLX 1000V operate inside continuous drag chains or moving axes?
Yes. VFD-TGK-FLX 1000V is built for continuous dynamic flexing with a minimum bending radius of 8 × OD across -25 °C to +90 °C operating temperatures.
How should the EMC shield of VFD-TGK-FLX 1000V be grounded at termination?
Bond the metallic screen circumferentially (360°) at both drive and motor ends using EMC cable glands or low-impedance shielding clamps to minimize high-frequency transfer impedance.
What standards, drum lengths, and test certificates accompany VFD-TGK-FLX 1000V?
VFD-TGK-FLX 1000V conforms to UL 1277 Type TC-ER, UL 2277 Type WTTC, CSA AWM I/II A/B FT4 (UL Oil Res I/II) and ships cut-to-length or on export drums with an EN 10204 3.1 routine test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for VFD-TGK-FLX 1000V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

VFD-TGK-FLX 1000 V Symmetrical Flex VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote