Fixed installation
Supplied in PVC, XLPE/LSZH, +200 °C FEP (RCA/SCA) and SWA armoured constructions for glass, steel and semiconductor plants.
Product
Noble-metal thermocouple compensating cable (IEC 60584-3 RCB/SCB 0…+100 °C and RCA/SCA 0…+200 °C; ANSI SX) with pure Copper (+ Cu) and low-nickel Copper-Nickel (− Cu11Ni, Alloy #11) conductors calibrated for Pt13Rh-Pt (R) and Pt10Rh-Pt (S) sensors.
Typical values for this cable type, based on IEC 60584-3 / ANSI MC96.1 (SX) / BS EN 50288-7 — confirmed in the datasheet and quotation for your order.
Application fit
Because extending Platinum-Rhodium wire beyond the furnace head is prohibitively expensive, RCB/SCB (0…+100 °C) and RCA/SCA (0…+200 °C) are universally used to connect Type R and Type S high-temperature thermocouples (+1000…+1600 °C) to control rooms.
Supplied in PVC, XLPE/LSZH, +200 °C FEP (RCA/SCA) and SWA armoured constructions for glass, steel and semiconductor plants.
SWA armoured execution protects underground glass-plant and steel-meltshop trunk cables.
Non-ferrous Cu/Cu11Ni conductors are completely immune to rust and moisture.
Designed for fixed plant installation, not continuous drag chains.
PUR Drag-Chain Control CableConstruction
Shown: RCB/SCB-PVC-PiMF 4×2×1.0 mm² (IEC 60584-3) with 7-wire stranded Cu (+) and Cu11Ni (−) conductors, Orange (+) / White (−) numbered insulation, individual & collective Al/PET screens and Orange RAL 2003 outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Matched Type RCB/SCB (SX) compensating conductors | Positive (+): High-purity Copper (Cu) · Negative (−): Low-nickel Copper-Nickel (Cu11Ni ~99.4 % Cu / 0.6 % Ni, Alloy #11), 7-wire strandedReplicates the ~6.5 µV/°C EMF curve of both Pt13Rh-Pt (R) and Pt10Rh-Pt (S) over 0…+100/+200 °C |
| 2 | Colour-coded core insulation | Flame-retardant PVC, XLPE or +200 °C FEP (IEC: + Orange / − White; ANSI SX: + Black / − Red)High insulation resistance preserves microvolt-level PtRh signals |
| 3 | Individual & collective Al/PET screens | Aluminium/PET laminated tape + 0.5 mm² tinned copper drain wire (OS or PiMF+OS)Critical electrostatic shielding for low-EMF (~6–11 µV/°C) noble-metal loops |
| 4 | Optional SWA or tinned copper braid | Unarmoured, tinned copper wire braid, or Galvanised Steel Wire Armour (SWA)Mechanical and magnetic shielding around electric-boosted glass tanks |
| 5 | Outer jacket (IEC Orange RAL 2003 or ANSI Green) | Flame-retardant PVC, Low-Smoke Zero-Halogen (LSZH), or fluoropolymer FEPIEC 60332-1-2 / IEC 60332-3-24 flame retardant |
Positive (+) Orange, Negative (−) White, Outer Jacket Orange (RAL 2003)
Positive (+) Black, Negative (−) Red, Outer Jacket Green per ASTM E230
FEP fluoropolymer insulated RCA/SCA alloy pair calibrated from 0 °C to +200 °C
Technical data
Sizes
1 to 24 pairs in PVC, +200 °C FEP (RCA/SCA) and XLPE/LSZH/SWA armoured constructions.
| Order designation | Configuration | Insulation / Sheath | Junction range | Outer Ø ≈ mm | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RCB / SCB PVC / PVC Screened Process Cables (0…+100 °C) | |||||||
| RCB/SCB-PVC-OS 1×2×0.5 | 1×2×0.5 mm² (7/0.30) | PVC / PVC (OS) | 0…+100 °C | 5.6 | 44 | 42 | |
| RCB/SCB-PVC-PiMF 2×2×0.5 | 2×2×0.5 mm² (7/0.30) | PVC / PVC (PiMF+OS) | 0…+100 °C | 8.6 | 84 | 64 | |
| RCB/SCB-PVC-PiMF 4×2×0.5 | 4×2×0.5 mm² (7/0.30) | PVC / PVC (PiMF+OS) | 0…+100 °C | 10.8 | 142 | 81 | |
| RCB/SCB-PVC-PiMF 8×2×0.5 | 8×2×0.5 mm² (7/0.30) | PVC / PVC (PiMF+OS) | 0…+100 °C | 14.1 | 246 | 106 | |
| RCB/SCB-PVC-PiMF 12×2×0.5 | 12×2×0.5 mm² (7/0.30) | PVC / PVC (PiMF+OS) | 0…+100 °C | 16.9 | 348 | 127 | |
| RCB/SCB-PVC-OS 1×2×1.0 | 1×2×1.0 mm² (7/0.43) | PVC / PVC (OS) | 0…+100 °C | 6.7 | 68 | 50 | |
| RCB/SCB-PVC-PiMF 4×2×1.0 | 4×2×1.0 mm² (7/0.43) | PVC / PVC (PiMF+OS) | 0…+100 °C | 12.8 | 212 | 96 | |
| RCB/SCB-PVC-OS 1×2×1.5 | 1×2×1.5 mm² (7/0.53) | PVC / PVC (OS) | 0…+100 °C | 7.5 | 92 | 56 | |
| RCB/SCB-PVC-PiMF 4×2×1.5 | 4×2×1.5 mm² (7/0.53) | PVC / PVC (PiMF+OS) | 0…+100 °C | 14.3 | 286 | 107 | |
| RCA / SCA FEP / FEP Hot-Head Compensating Cables (0…+200 °C) | |||||||
| RCA/SCA-FEP-OS 1×2×1.0 | 1×2×1.0 mm² (7/0.43) | FEP / FEP (OS) | 0…+200 °C | 5.6 | 58 | 42 | |
| RCA/SCA-FEP-PiMF 4×2×1.0 | 4×2×1.0 mm² (7/0.43) | FEP / FEP (PiMF+OS) | 0…+200 °C | 11.2 | 188 | 84 | |
| RCB / SCB XLPE / LSZH / SWA Armoured Direct-Burial (0…+90 °C) | |||||||
| RCB/SCB-XLPE-SWA 1×2×1.5 | 1×2×1.5 mm² (7/0.53) | XLPE / SWA / LSZH | 0…+90 °C | 12.1 | 298 | 121 | |
| RCB/SCB-XLPE-SWA 4×2×1.5 | 4×2×1.5 mm² (7/0.53) | XLPE / SWA / LSZH | 0…+90 °C | 19.8 | 745 | 198 | |
| Conductor size | (+) Cu R₂₀ Ω/m ≈ | (−) Cu11Ni R₂₀ Ω/m ≈ | Loop R₂₀ / pair Ω/m ≈ | Class 2 tol. (at +1000 °C) |
|---|---|---|---|---|
| 0.50 mm² (7/0.30 mm) | 0.036 | 0.059 | 0.095 | ±5.0 °C (±60 µV) |
| 0.75 mm² (7/0.37 mm) | 0.025 | 0.040 | 0.065 | ±5.0 °C (±60 µV) |
| 1.00 mm² (7/0.43 mm) | 0.018 | 0.030 | 0.048 | ±5.0 °C (±60 µV) |
| 1.50 mm² (7/0.53 mm) | 0.012 | 0.020 | 0.032 | ±5.0 °C (±60 µV) |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Thermoelectric EMF calibration test (IEC 60584-3 Class 2) | EMF deviation within ±60 µV (±5.0 °C at +1000 °C) over 0…+100/+200 °C | Every alloy batch |
| 1500 V / 2000 V AC dielectric & continuity test | 1 min AC withstand test without breakdown | Every manufactured drum |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.