Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per EN 50288-7 / IEC 60584-3 / IEC 60332-3-22.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 across -30 to +80 °C.
Typical values for this cable type, based on EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 across -30 to +80 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per EN 50288-7 / IEC 60584-3 / IEC 60332-3-22.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +80 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: TT PVC-oST-PVC-SWA-PVC (EN 50288-7 / IEC 60584-3 / IEC 60332-3-22) featuring thermocouple alloy conductors (4×2×1.3), polarity-coded pvc insulation and hydrocarbon-resistant outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Thermocouple Alloy Conductors (4×2×1.3) | Solid IEC 60584-3 Type KX alloy conductors (+NiCr / -NiAl) |
| 2 | Polarity-Coded PVC Insulation | IEC 60584-3 color-coded PVC pairs (Green positive / White negative) |
| 3 | Overall Foil Screen (oST) | Aluminum/PET tape electrostatic shield + tinned copper drain wire |
| 4 | PVC Inner Sheath & Round SWA | Extruded PVC inner bedding + galvanized round steel wire armour (SWA) |
| 5 | Hydrocarbon-Resistant Outer Sheath | IEC 60584-3 green Cat. A flame-retardant & oil-resistant PVC jacket |
Built to EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 with thermocouple alloy conductors (4×2×1.3) and hydrocarbon-resistant outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TT PVC-oST-PVC-SWA-PVC Construction Schedule (-30 to +80 °C) | |||||||
| TT PVC-oST-PVC-SWA-PVC 2×2×1.3 mm² KX | 2 × 2 × 1.3 mm² Type KX (+NiCr/-NiAl) | Solid Ø 1.29 mm (16 AWG) | 13.8 | 365 | 4.5 | 165 | |
| TT PVC-oST-PVC-SWA-PVC 4×2×1.3 mm² KX | 4 × 2 × 1.3 mm² Type KX (+NiCr/-NiAl) | Solid Ø 1.29 mm (16 AWG) | 16.4 | 520 | 6.2 | 195 | |
| TT PVC-oST-PVC-SWA-PVC 12×2×1.3 mm² KX | 12 × 2 × 1.3 mm² Type KX (+NiCr/-NiAl) | Solid Ø 1.29 mm (16 AWG) | 23.6 | 1,080 | 11.5 | 285 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 1.3 mm² Type KX | 77.00 | Class 1 EMF tolerance (±1.5 °C) | -30 to +80 °C |
| 4 × 2 × 1.3 mm² Type KX | 77.00 | Class 1 EMF tolerance (±1.5 °C) | -30 to +80 °C |
| 12 × 2 × 1.3 mm² Type KX | 77.00 | Class 1 EMF tolerance (±1.5 °C) | -30 to +80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (EN 50288-7 / IEC 60584-3 / IEC 60332-3-22) | DC resistance at 20 °C / optical attenuation and outer diameter within EN 50288-7 / IEC 60584-3 / IEC 60332-3-22 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (EN 50288-7 / IEC 60584-3 / IEC 60332-3-22) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (EN 50288-7 / IEC 60584-3 / IEC 60332-3-22) | Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking