Contact
subsea umbilical, ROV tether & oceanographic tow cableType 306 / 2530 Sonar Hybrid300 V – 600 V (-30 to +80 °C)Black Polyurethane (PUR) Outer Jacke

Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow CableType 306 / 2530 Sonar Hybrid — 300 V – 600 V — -30 to +80 °C Subsea & Offshore Cable

Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow Cable featuring central coaxial core and black polyurethane (pur) outer jacket (Type 306 / 2530 Sonar Hybrid, 300 V – 600 V, -30 to +80 °C).

Water-resistant
EMC screen
Oil-resistant
Approved
Order designation
Type 306 Coax / Cat5e
Outer Ø ≈
8.2 mm
Net weight ≈
245 kg/km
Tensile rating ≈
42.7 kN
Core / stranding
Stranded SnCu + Foam PE/FEP + Armour/Aramid
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V – 600 V
Tested per Type 306 / 2530 Sonar Hybrid
Operating temp.
−30…+80 °C
Continuous subsea & offshore service
Min. bend radius
8 × OD
Winch sheave, chute & seabed routing
Core / conductor
Central Coaxial
Impedance-controlled coaxial unit for so
Outer protection
Black Polyuretha
Heavy-duty black PUR outer sheath for so
Standard
Type 306 / 2530
Type 306 / 2530 Coaxial + Screened Pairs

Typical values for this cable type, based on Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Type 306 / 2530 right for your machine?

Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow Cable featuring central coaxial core and black polyurethane (pur) outer jacket (Type 306 / 2530 Sonar Hybrid, 300 V – 600 V, -30 to +80 °C).

Immersion & wet locations

Suitable

Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.

Vertical / spreader reel

Suitable

Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling

Trailing & towing

Suitable

Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.

Offshore platform & shipboard deck trays

Suitable

UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.

Energy chain / drag chain

Not suitable

Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.

Use M23 Servo Assembly
Typical machinesUnderwater & Ocean ExplorationOceanographic CTD, ADCP & Deep-Tow SurveysWork-Class & Observation ROV / AUV SystemsSide-Scan Sonar, SAS & Towed Hydrophone ArraysMarine 2D/3D/UHR Seismic Streamers & OBC

Construction

Layer by layer

Shown: Type 306 / 2530 (Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification) featuring central coaxial core, 300v-600v power & signal cores (6 cores) and black polyurethane (pur) outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Coaxial CoreImpedance-controlled coaxial unit for sonar acoustic transmission
2300V-600V Power & Signal Cores (6 Cores)Stranded tinned copper conductors with XLPE/PE insulation
3Aramid Braided Strength MemberHigh-tensile aramid fiber braid over inner bedding sheath
4Black Polyurethane (PUR) Outer JacketHeavy-duty black PUR outer sheath for sonar towfish & profilers

Type 306 / 2530 — Standard Subsea & Offshore Execution

Built to Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification with central coaxial core and black polyurethane (pur) outer jacket

Type 306 / 2530 — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

Type 306 / 2530 — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300 V – 600 V (Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification)
Core / conductor construction
Central Coaxial Core — Impedance-controlled coaxial unit for sonar acoustic transmission
Primary dielectric / buffering
300V-600V Power & Signal Cores (6 Cores) — Stranded tinned copper conductors with XLPE/PE insulation

Thermal

Continuous operating temperature
−30…+80 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Black Polyurethane (PUR) Outer Jacket — Heavy-duty black PUR outer sheath for sonar towfish & profilers
Minimum bending radius
8 × OD
Armour, strength member & mechanical duty
Aramid Braided Strength Member — High-tensile aramid fiber braid over inner bedding sheath

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Type 306 / 2530
Sheath colour & metre marking
Continuous metre-marked black outer finish (Black Polyuretha)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Type 306 / 2530 subsea & offshore configurations

Manufactured to Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
Type 306 / 2530 Construction Schedule (−30…+80 °C)
Type 306 Coax / Cat5eCoax (39/40/50/75 Ω) or 4Pr Cat5e + PowerStranded SnCu + Foam PE/FEP + Armour/Aramid8.224542.7120
Type 306 Composite BHeavy Coax / 64-Ch Digital Bus + PowerStranded SnCu + Low-Loss Dielectric + Strength11.548571.2170
Type 306 Array / Trunk CMulti-Ch Digital Streamer / 255-Ch BusRedundant Telemetry + Aramid + PUR Jacket44.51,62095.0445
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification)DC resistance at 20 °C / optical attenuation and outer diameter within Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification)Zero dielectric breakdown and verified insulation resistance for 300 V – 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Type 306 / 2530 Sonar Hybrid CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Type 306 / 2530 Type 306 / 2530 Sonar Hybrid 300 V – 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Type 306 / 2530 (Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow Cable)?
Type 306 / 2530 (Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow Cable) is manufactured in accordance with Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification for 300 V – 600 V service over -30 to +80 °C. Its 4-layer construction comprises central coaxial core, 300v-600v power & signal cores (6 cores) and black polyurethane (pur) outer jacket.
What is the minimum bending radius and operating temperature range for Type 306 / 2530?
The minimum bending radius for Type 306 / 2530 is 8 × OD across its continuous operating temperature range of -30 to +80 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of Type 306 / 2530 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Coaxial Core — Impedance-controlled coaxial unit for sonar acoustic transmission; (02) 300V-600V Power & Signal Cores (6 Cores) — Stranded tinned copper conductors with XLPE/PE insulation; (03) Aramid Braided Strength Member — High-tensile aramid fiber braid over inner bedding sheath; (04) Black Polyurethane (PUR) Outer Jacket — Heavy-duty black PUR outer sheath for sonar towfish & profilers.
What factory test certificates are supplied with Type 306 / 2530?
Every production drum of Type 306 / 2530 undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per Type 306 / 2530 Coaxial + Screened Pairs + Aramid Subsea Sonar Tow Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Type 306 / 2530

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Type 306 / 2530 300–600 V Side-Scan Sonar & Sub-Bottom Profiler Hybrid Coaxial Tow Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote