Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
Type 4622CC 300 V / 75 V ADCP & CTD Oceanographic Subsea Sensor Data Cable featuring tinned copper power cores (2×1.00 mm²) and black polyurethane (pur) outer jacket (IEC 60092-350 / Subsea Sensor, 300 V / 75 V, -30 to +80 °C).
Typical values for this cable type, based on IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification — confirmed in the datasheet and quotation for your order.
Application fit
Type 4622CC 300 V / 75 V ADCP & CTD Oceanographic Subsea Sensor Data Cable featuring tinned copper power cores (2×1.00 mm²) and black polyurethane (pur) outer jacket (IEC 60092-350 / Subsea Sensor, 300 V / 75 V, -30 to +80 °C).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: Type 4622CC (IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification) featuring tinned copper power cores (2×1.00 mm²), foil-screened data pairs (6×2×0.22 mm²) and black polyurethane (pur) outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Power Cores (2×1.00 mm²) | 300 V XLPE insulated tinned copper power conductors |
| 2 | Foil-Screened Data Pairs (6×2×0.22 mm²) | 75 V polyolefin twisted pairs with individual Al/PET foil screens |
| 3 | LLDPE Inner Bedding Sheath | Extruded linear low-density polyethylene inner protective sheath |
| 4 | Black Polyurethane (PUR) Outer Jacket | Seawater- and abrasion-resistant black PUR outer sheath (Ø 9.60 mm) |
Built to IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification with tinned copper power cores (2×1.00 mm²) and black polyurethane (pur) outer jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Type 4622CC Construction Schedule (−30…+80 °C) | |||||||
| Type 4622CC 4Pr / 8Ch | 4×2×24–20 AWG (or 8-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 11.2 | 175 | 12.5 | 90 | |
| Type 4622CC 8Pr / 16Ch | 8×2×22–18 AWG (or 16-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 16.4 | 340 | 24.0 | 130 | |
| Type 4622CC 16Pr / 24Ch | 16×2×18–16 AWG (or 24-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 24.8 | 690 | 35.0 | 195 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24–20 AWG (or 8-Ch Array) | 42.00 | 300 V / 75 V (≤55 nF/km) | −30…+80 °C |
| 8×2×22–18 AWG (or 16-Ch Array) | 26.00 | 300 V / 75 V (≤60 nF/km) | −30…+80 °C |
| 16×2×18–16 AWG (or 24-Ch Array) | 15.20 | 300 V / 75 V (≤65 nF/km) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification) | Zero dielectric breakdown and verified insulation resistance for 300 V / 75 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEC 60092-350 / Oceanographic ADCP & CTD Subsea Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.