Contact
6,000 m deepwater subsea ADCP & acoustic telemetry cable6,000 m (600 bar) Rated1,000 V DC + 600 V PairsSubsea ADCP Telemetry

Type 4591CC / Type 4026 6,000m Deepwater ADCP & Telemetry PUR CableIEC 60228 / 600 bar · 0.6/1 kV · 6,000 m deepwater subsea adcp & acoustic telemetry cable

6,000m Deepwater Subsea ADCP, Acoustic Telemetry & Instrument Power/Data Hybrid Polyurethane Cable Family (Type 4026, Type 4591CC, Type 4622CC, Type 4971CC, Type 9880CC) (IEC 60228 / 600 bar, 0.6/1 kV, -30 °C to +80 °C).

Water-resistant
EMC screen
Low-EMC design
Oil-resistant
Order designation
TYPE 4591CC Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60228 / 600 bar
Operating temp.
−30…+80 °C
Continuous subsea & marine service
Min. bend radius
10 × OD
Dynamic sheave & fixed routing
Core / conductor
1×3×1.5
1,000 V DC XLPE power triad
Outer protection
85A Polyether
Halogen-free 85 Shore A black polyether
Standard
IEC 60228
IEC 60228

Typical values for this cable type, based on IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry — confirmed in the datasheet and quotation for your order.

Application fit

Is TYPE 4591CC / TYPE 4026 right for your machine?

6,000m Deepwater Subsea ADCP, Acoustic Telemetry & Instrument Power/Data Hybrid Polyurethane Cable Family (Type 4026, Type 4591CC, Type 4622CC, Type 4971CC, Type 9880CC) (IEC 60228 / 600 bar, 0.6/1 kV, -30 °C to +80 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: TYPE 4591CC / TYPE 4026 (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry) featuring center screened power triad (1×3×1.50 mm²), screened twisted pairs (8×2×0.50 mm²) and halogen-free polyether pur jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Center Screened Power Triad (1×3×1.50 mm²)30/0.25 mm tinned Cu + Blue/White/Red XLPE (1,000 V DC) + drain + Ali/PET foil
2Screened Twisted Pairs (8×2×0.50 mm²)16/0.20 mm tinned Cu + XLPE (600 V DC) + drain + 12/23 µm Ali/PET foil + PET tape
3Waterblocking System (6,000 m Rated)Overall water-swellable tape (Type 4591CC) or SEBS sheath + silicone fill (Type 4026)
4Halogen-Free Polyether PUR Jacket1.80 mm black 85 Shore A polyether polyurethane outer sheath (Ø 16.40 mm)

TYPE 4591CC / TYPE 4026 — Standard Subsea & Marine Execution

Built to IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry with center screened power triad (1×3×1.50 mm²) and halogen-free polyether pur jacket

TYPE 4591CC / TYPE 4026 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

TYPE 4591CC / TYPE 4026 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry)
Core / conductor construction
Center Screened Power Triad (1×3×1.50 mm²) — 30/0.25 mm tinned Cu + Blue/White/Red XLPE (1,000 V DC) + drain + Ali/PET foil
Primary dielectric / buffering
Screened Twisted Pairs (8×2×0.50 mm²) — 16/0.20 mm tinned Cu + XLPE (600 V DC) + drain + 12/23 µm Ali/PET foil + PET tape

Thermal

Continuous operating temperature
−30…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Halogen-Free Polyether PUR Jacket — 1.80 mm black 85 Shore A polyether polyurethane outer sheath (Ø 16.40 mm)
Minimum bending radius
10 × OD
Hydrostatic, tensile & crush duty
Waterblocking System (6,000 m Rated) — Overall water-swellable tape (Type 4591CC) or SEBS sheath + silicone fill (Type 4026)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TYPE 4591CC / TYPE 4026
Sheath colour & metre marking
Continuous metre-marked black outer finish (85A Polyether PUR)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard TYPE 4591CC / TYPE 4026 subsea & marine configurations

Manufactured to IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
TYPE 4591CC / TYPE 4026 Construction Schedule (−30…+80 °C)
TYPE 4591CC Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
TYPE 4591CC Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
TYPE 4591CC Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry)Verified submersion integrity, tensile load and thermal stability across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60228 / 600 bar CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TYPE 4591CC / TYPE 4026 IEC 60228 / 600 bar 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TYPE 4591CC / TYPE 4026 (Type 4591CC / Type 4026 6,000m Deepwater ADCP & Telemetry PUR Cable)?
TYPE 4591CC / TYPE 4026 (Type 4591CC / Type 4026 6,000m Deepwater ADCP & Telemetry PUR Cable) is manufactured in accordance with IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry for 0.6/1 kV service over -30 °C to +80 °C. Its 4-layer construction comprises center screened power triad (1×3×1.50 mm²), screened twisted pairs (8×2×0.50 mm²) and halogen-free polyether pur jacket.
What is the minimum bending radius and operating temperature range for TYPE 4591CC / TYPE 4026?
The minimum bending radius for TYPE 4591CC / TYPE 4026 is 10 × OD across its continuous operating temperature range of -30 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of TYPE 4591CC / TYPE 4026 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Center Screened Power Triad (1×3×1.50 mm²) — 30/0.25 mm tinned Cu + Blue/White/Red XLPE (1,000 V DC) + drain + Ali/PET foil; (02) Screened Twisted Pairs (8×2×0.50 mm²) — 16/0.20 mm tinned Cu + XLPE (600 V DC) + drain + 12/23 µm Ali/PET foil + PET tape; (03) Waterblocking System (6,000 m Rated) — Overall water-swellable tape (Type 4591CC) or SEBS sheath + silicone fill (Type 4026); (04) Halogen-Free Polyether PUR Jacket — 1.80 mm black 85 Shore A polyether polyurethane outer sheath (Ø 16.40 mm).
What factory test certificates are supplied with TYPE 4591CC / TYPE 4026?
Every production drum of TYPE 4591CC / TYPE 4026 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TYPE 4591CC / TYPE 4026

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Type 4591CC / Type 4026 6,000m Deepwater ADCP & Telemetry PUR Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote