Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
6,000m Deepwater Subsea ADCP, Acoustic Telemetry & Instrument Power/Data Hybrid Polyurethane Cable Family (Type 4026, Type 4591CC, Type 4622CC, Type 4971CC, Type 9880CC) (IEC 60228 / 600 bar, 0.6/1 kV, -30 °C to +80 °C).
Typical values for this cable type, based on IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry — confirmed in the datasheet and quotation for your order.
Application fit
6,000m Deepwater Subsea ADCP, Acoustic Telemetry & Instrument Power/Data Hybrid Polyurethane Cable Family (Type 4026, Type 4591CC, Type 4622CC, Type 4971CC, Type 9880CC) (IEC 60228 / 600 bar, 0.6/1 kV, -30 °C to +80 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: TYPE 4591CC / TYPE 4026 (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry) featuring center screened power triad (1×3×1.50 mm²), screened twisted pairs (8×2×0.50 mm²) and halogen-free polyether pur jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center Screened Power Triad (1×3×1.50 mm²) | 30/0.25 mm tinned Cu + Blue/White/Red XLPE (1,000 V DC) + drain + Ali/PET foil |
| 2 | Screened Twisted Pairs (8×2×0.50 mm²) | 16/0.20 mm tinned Cu + XLPE (600 V DC) + drain + 12/23 µm Ali/PET foil + PET tape |
| 3 | Waterblocking System (6,000 m Rated) | Overall water-swellable tape (Type 4591CC) or SEBS sheath + silicone fill (Type 4026) |
| 4 | Halogen-Free Polyether PUR Jacket | 1.80 mm black 85 Shore A polyether polyurethane outer sheath (Ø 16.40 mm) |
Built to IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry with center screened power triad (1×3×1.50 mm²) and halogen-free polyether pur jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TYPE 4591CC / TYPE 4026 Construction Schedule (−30…+80 °C) | |||||||
| TYPE 4591CC Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| TYPE 4591CC Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| TYPE 4591CC Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / 6,000 m (600 bar) Subsea ADCP & Telemetry) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.