Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
TPT, TPT-CW/SB & TP(OS)PNBS 300/600 V IEEE 1580 Type P Overall Shielded Offshore Rig Instrumentation Cable (IEEE 1580 Type P / UL 1309) engineered for 300/600 V service across -40 to +125 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS) — confirmed in the datasheet and quotation for your order.
Application fit
TPT, TPT-CW/SB & TP(OS)PNBS 300/600 V IEEE 1580 Type P Overall Shielded Offshore Rig Instrumentation Cable (IEEE 1580 Type P / UL 1309) engineered for 300/600 V service across -40 to +125 °C (min. bend radius 6 × OD).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: TPT & TPT-CW/SB / TP(OS)PNBS (IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS)) featuring flexible tinned copper pairs (4pr × 16 awg), 100% overall al/pet shield & drain (os) and arctic type p mud-resistant jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Tinned Copper Pairs (4Pr × 16 A | 19-strand tinned copper with 125 °C XLPO Black/White numbered insulation |
| 2 | 100% Overall Al/PET Shield & Drain (OS) | Collective aluminum/polyester tape shield with tinned copper drain wire |
| 3 | Thermoset Inner Bedding Jacket | Flame-retardant elastomeric inner sheath isolating shield from armour |
| 4 | Bronze / Copper Wire Braid (SB / -CW) | Braided bronze or tinned copper mechanical armour |
| 5 | Arctic Type P Mud-Resistant Jacket | Heavy-duty thermoset outer sheath for offshore drilling rigs |
Built to IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS) with flexible tinned copper pairs (4pr × 16 awg) and arctic type p mud-resistant jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TPT & TPT-CW/SB / TP(OS)PNBS Construction Schedule (−40…+125 °C) | |||||||
| TPT 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| TPT 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| TPT 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 300/600 V (≤60 nF/km) | −40…+125 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 300/600 V (≤65 nF/km) | −40…+125 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 300/600 V (≤75 nF/km) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS)) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS)) | Zero dielectric breakdown and verified insulation resistance for 300/600 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEEE 1580 Type P & UL 1309 Overall Foil-Shielded (OS)) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.