(N)3GRDC5G-J/O 0.6/1 kV Screened Rubber Festoon CableVDE 0250-812 · 0.6/1 kV · Screened rubber festoon & drag-chain power cable

(N)3GRDC5G-J/O 0.6/1 kV (Max 1.2 kV) Class 5 Bare-Copper HEPR-Insulated GM1b Inner-Sheathed 80% Tinned-Copper/Synthetic-Fibre Screened 5GM5 CR Festoon & Drag-Chain Cable (VDE 0250-812, 0.6/1 kV, -40 °C to +90 °C).

EMC screen
Oil-resistant
Flame-retardant
Outdoor & humid
Order designation
(N)3GRDC5G-J/O Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per VDE 0250-812
Operating temp.
−40…+90 °C
Continuous subsea & marine service
Min. bend radius
7.5 × OD
Dynamic sheave & fixed routing
Core / conductor
3–5×16–95 mm² Cu
VDE 0295 Class 5 flexible bare Cu
Outer protection
5GM5 Black CR
80% SnCu/textile braid + 5GM5 CR sheath
Standard
VDE 0250-812
DIN VDE 0250-812 / IEC 60332-1-2

Typical values for this cable type, based on DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 — confirmed in the datasheet and quotation for your order.

Application fit

Is (N)3GRDC5G-J/O right for your machine?

(N)3GRDC5G-J/O 0.6/1 kV (Max 1.2 kV) Class 5 Bare-Copper HEPR-Insulated GM1b Inner-Sheathed 80% Tinned-Copper/Synthetic-Fibre Screened 5GM5 CR Festoon & Drag-Chain Cable (VDE 0250-812, 0.6/1 kV, -40 °C to +90 °C).

Festoon & line chain

Suitable

5GM5 polychloroprene sheath and anti-torsion screened core support festoon speeds up to 240 m/min.

Energy chain / drag chain

Suitable

Low-friction GM1b inner bedding and 80% copper/synthetic braid withstand motorized energy-chain travel.

Motorised monospiral reel

Suitable

Flexible Class 5 copper and HEPR insulation handle horizontal reeling andguided travel on port cranes.

Immersion & wet locations

Suitable

Oil-, UV- and weather-resistant 5GM5 rubber jacket operates reliably in coastal and offshore port climates.

Drilling jumbo & rotary mast feed

Not suitable

Crane festoon cable is not intended for downhole oilfield ESP or blowout-preventer service.

Use A304739 BOP MUX Umbilical
Typical machinesMarine & Offshore CableShip-to-Shore (STS) Container CranesRTG, RMG & Automated Stacking CranesHeavy Steelwork & Bulk Port HoistsOffshore Deck & Shipyard Gantries

Construction

Layer by layer

Shown: (N)3GRDC5G-J/O (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404) featuring phase conductors (3×35 mm² bare cu), split pe conductors (3g6 mm²) and outer sheath (black 5gm5 cr rubber) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (3×35 mm² Bare Cu)VDE 0295 Class 5 flexible plain copper with numbered tan HEPR (3G) insulation
2Split PE Conductors (3G6 mm²)Three symmetrical green/yellow HEPR protective earth cores in outer valleys
3Inner Rubber Sheath (GM1b)Extruded light-colored GM1b rubber inner sheath stabilizing core geometry
4Tinned Cu + Synthetic Fibre Braid (80% C5G)80%-coverage tinned copper wire + synthetic fibre hybrid screen over inner sheath
5Outer Sheath (Black 5GM5 CR Rubber)Flame-retardant (IEC 60332-1-2), oil- (EN 60811-404) & UV-resistant CR jacket (240 m/min)

(N)3GRDC5G-J/O — Standard Subsea & Marine Execution

Built to DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 with phase conductors (3×35 mm² bare cu) and outer sheath (black 5gm5 cr rubber)

(N)3GRDC5G-J/O — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

(N)3GRDC5G-J/O — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404)
Core / conductor construction
Phase Conductors (3×35 mm² Bare Cu) — VDE 0295 Class 5 flexible plain copper with numbered tan HEPR (3G) insulation
Primary dielectric / buffering
Split PE Conductors (3G6 mm²) — Three symmetrical green/yellow HEPR protective earth cores in outer valleys

Thermal

Continuous operating temperature
−40…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Outer Sheath (Black 5GM5 CR Rubber) — Flame-retardant (IEC 60332-1-2), oil- (EN 60811-404) & UV-resistant CR jacket (240 m/min)
Minimum bending radius
7.5 × OD
Hydrostatic, tensile & crush duty
Tinned Cu + Synthetic Fibre Braid (80% C5G) — 80%-coverage tinned copper wire + synthetic fibre hybrid screen over inner sheath

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
(N)3GRDC5G-J/O
Sheath colour & metre marking
Continuous metre-marked black outer finish (5GM5 Black CR)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard (N)3GRDC5G-J/O subsea & marine configurations

Manufactured to DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
(N)3GRDC5G-J/O Construction Schedule (−40…+90 °C)
(N)3GRDC5G-J/O Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
(N)3GRDC5G-J/O Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
(N)3GRDC5G-J/O Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404)DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404)Verified submersion integrity, tensile load and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0250-812 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX (N)3GRDC5G-J/O VDE 0250-812 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define (N)3GRDC5G-J/O ((N)3GRDC5G-J/O 0.6/1 kV Screened Rubber Festoon Cable)?
(N)3GRDC5G-J/O ((N)3GRDC5G-J/O 0.6/1 kV Screened Rubber Festoon Cable) is manufactured in accordance with DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 for 0.6/1 kV service over -40 °C to +90 °C. Its 5-layer construction comprises phase conductors (3×35 mm² bare cu), split pe conductors (3g6 mm²) and outer sheath (black 5gm5 cr rubber).
What is the minimum bending radius and operating temperature range for (N)3GRDC5G-J/O?
The minimum bending radius for (N)3GRDC5G-J/O is 7.5 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of (N)3GRDC5G-J/O arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (3×35 mm² Bare Cu) — VDE 0295 Class 5 flexible plain copper with numbered tan HEPR (3G) insulation; (02) Split PE Conductors (3G6 mm²) — Three symmetrical green/yellow HEPR protective earth cores in outer valleys; (03) Inner Rubber Sheath (GM1b) — Extruded light-colored GM1b rubber inner sheath stabilizing core geometry; (04) Tinned Cu + Synthetic Fibre Braid (80% C5G) — 80%-coverage tinned copper wire + synthetic fibre hybrid screen over inner sheath; (05) Outer Sheath (Black 5GM5 CR Rubber) — Flame-retardant (IEC 60332-1-2), oil- (EN 60811-404) & UV-resistant CR jacket (240 m/min).
What factory test certificates are supplied with (N)3GRDC5G-J/O?
Every production drum of (N)3GRDC5G-J/O undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for (N)3GRDC5G-J/O

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

(N)3GRDC5G-J/O 0.6/1 kV Screened Rubber Festoon Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote