Festoon & line chain
5GM5 polychloroprene sheath and anti-torsion screened core support festoon speeds up to 240 m/min.
Product
(N)3GRDC5G-J/O 0.6/1 kV (Max 1.2 kV) Class 5 Bare-Copper HEPR-Insulated GM1b Inner-Sheathed 80% Tinned-Copper/Synthetic-Fibre Screened 5GM5 CR Festoon & Drag-Chain Cable (VDE 0250-812, 0.6/1 kV, -40 °C to +90 °C).
Typical values for this cable type, based on DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 — confirmed in the datasheet and quotation for your order.
Application fit
(N)3GRDC5G-J/O 0.6/1 kV (Max 1.2 kV) Class 5 Bare-Copper HEPR-Insulated GM1b Inner-Sheathed 80% Tinned-Copper/Synthetic-Fibre Screened 5GM5 CR Festoon & Drag-Chain Cable (VDE 0250-812, 0.6/1 kV, -40 °C to +90 °C).
5GM5 polychloroprene sheath and anti-torsion screened core support festoon speeds up to 240 m/min.
Low-friction GM1b inner bedding and 80% copper/synthetic braid withstand motorized energy-chain travel.
Flexible Class 5 copper and HEPR insulation handle horizontal reeling andguided travel on port cranes.
Oil-, UV- and weather-resistant 5GM5 rubber jacket operates reliably in coastal and offshore port climates.
Crane festoon cable is not intended for downhole oilfield ESP or blowout-preventer service.
Use A304739 BOP MUX UmbilicalConstruction
Shown: (N)3GRDC5G-J/O (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404) featuring phase conductors (3×35 mm² bare cu), split pe conductors (3g6 mm²) and outer sheath (black 5gm5 cr rubber) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×35 mm² Bare Cu) | VDE 0295 Class 5 flexible plain copper with numbered tan HEPR (3G) insulation |
| 2 | Split PE Conductors (3G6 mm²) | Three symmetrical green/yellow HEPR protective earth cores in outer valleys |
| 3 | Inner Rubber Sheath (GM1b) | Extruded light-colored GM1b rubber inner sheath stabilizing core geometry |
| 4 | Tinned Cu + Synthetic Fibre Braid (80% C5G) | 80%-coverage tinned copper wire + synthetic fibre hybrid screen over inner sheath |
| 5 | Outer Sheath (Black 5GM5 CR Rubber) | Flame-retardant (IEC 60332-1-2), oil- (EN 60811-404) & UV-resistant CR jacket (240 m/min) |
Built to DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 with phase conductors (3×35 mm² bare cu) and outer sheath (black 5gm5 cr rubber)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| (N)3GRDC5G-J/O Construction Schedule (−40…+90 °C) | |||||||
| (N)3GRDC5G-J/O Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| (N)3GRDC5G-J/O Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| (N)3GRDC5G-J/O Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −40…+90 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −40…+90 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0250-812 / IEC 60332-1-2 / EN 60811-404) | Verified submersion integrity, tensile load and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.