Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
TC6A 4,000m Pressure-Balanced Oil-Filled (PBOF) Subsea EFL Assembly (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) engineered for 1.8/3 kV service across -20 °C to +70 °C (min. bend radius 10 × OD).
Typical values for this cable type, based on API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard — confirmed in the datasheet and quotation for your order.
Application fit
TC6A 4,000m Pressure-Balanced Oil-Filled (PBOF) Subsea EFL Assembly (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) engineered for 1.8/3 kV service across -20 °C to +70 °C (min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: TC6A PBOF EFL (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) featuring power & tsp comms cores (4 / 7 / 12-way), dielectric oil compensation medium and tc6a wet-mateable connector (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Power & TSP Comms Cores (4 / 7 / 12-Way) | 1,000/2,000 V rms power cores (20–40 A) + twisted screened pairs (RS-485/CAN) |
| 2 | Dielectric Oil Compensation Medium | 15 bar pre-filled dielectric fluid balancing hydrostatic pressure to 4,000 m (400 bar) |
| 3 | TC6A-700 / TC6A-712 PBOF Hose Wall | Elastomeric liner + synthetic braid (11 kN ultimate load, 90 bar burst) + yellow cover |
| 4 | TC6A Wet-Mateable Connector | Super-Duplex UNS S32550 shell + Alloy 625 inlay + dual-diaphragm shuttle-pin insert |
Built to API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard with power & tsp comms cores (4 / 7 / 12-way) and tc6a wet-mateable connector
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TC6A PBOF EFL Construction Schedule (−20…+70 °C) | |||||||
| TC6A PBOF EFL Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| TC6A PBOF EFL Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| TC6A PBOF EFL Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 1.8/3 kV (45–100 Ω data) | −20…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 1.8/3 kV (45–100 Ω data) | −20…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 1.8/3 kV (High-Power Hybrid) | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (API Spec 17F / ISO 13628-6 4,000 m PBOF EFL Standard) | Verified submersion integrity, tensile load and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.