Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
SURF ISO 13628-5 / API Spec 17E Super-Duplex Stainless Steel Tube Umbilical (STU) for Subsea Chemical Injection, Hydraulic Control, Gas Lift & Electro-Optical Transmission (ISO 13628-5 / API 17E, 6/10 kV, -20 °C to +90 °C).
Typical values for this cable type, based on ISO 13628-5 / API Spec 17E Super-Duplex STU Standard — confirmed in the datasheet and quotation for your order.
Application fit
SURF ISO 13628-5 / API Spec 17E Super-Duplex Stainless Steel Tube Umbilical (STU) for Subsea Chemical Injection, Hydraulic Control, Gas Lift & Electro-Optical Transmission (ISO 13628-5 / API 17E, 6/10 kV, -20 °C to +90 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: SURF SUPER-DUPLEX STU (ISO 13628-5 / API Spec 17E Super-Duplex STU Standard) featuring center meg / chemical injection tube, 15,000 psi sdss hydraulic tubes (6×) and galvanized steel armour & hdpe sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center MEG / Chemical Injection Tube | Large-bore Super-Duplex Stainless Steel (UNS S32750) tube with PE/PA11 oversheath |
| 2 | 15,000 PSI SDSS Hydraulic Tubes (6×) | Cold-drawn UNS S32750 tubes (Rp0.2 ≥ 550 MPa) with individual polymeric oversheaths |
| 3 | Control Quads & Armoured FO Cables | 4 × 0.6/1 kV screened XLPE control quads + 2 × armoured single-mode optical cables |
| 4 | Pre-Shaped Polymeric Profile Fillers | Extruded grooved PVC/PE profile fillers locking tubes and cables in exact geometry |
| 5 | Galvanized Steel Armour & HDPE Sheath | Helically wound galvanized steel armour + black/yellow HDPE outer jacket |
Built to ISO 13628-5 / API Spec 17E Super-Duplex STU Standard with center meg / chemical injection tube and galvanized steel armour & hdpe sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ISO 13628-5 / API Spec 17E Super-Duplex STU Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SURF SUPER-DUPLEX STU Construction Schedule (−20…+90 °C) | |||||||
| SURF SUPER-DUPLEX STU 3×240 mm² + FO | 3 × 240 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 118.0 | 26,400 | 320.0 | 1,770 | |
| SURF SUPER-DUPLEX STU 3×400 mm² + FO | 3 × 400 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 134.0 | 34,800 | 420.0 | 2,010 | |
| SURF SUPER-DUPLEX STU 3×630 mm² + FO | 3 × 630 mm² + 96F FIMT | IEC 60228 Class 2 water-blocked Cu | 152.0 | 46,200 | 560.0 | 2,280 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 240 mm² + 48F FIMT | 0.08 | 6/10 kV (560 A) | −20…+90 °C |
| 3 × 400 mm² + 48F FIMT | 0.05 | 6/10 kV (710 A) | −20…+90 °C |
| 3 × 630 mm² + 96F FIMT | 0.03 | 6/10 kV (890 A) | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ISO 13628-5 / API Spec 17E Super-Duplex STU Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ISO 13628-5 / API Spec 17E Super-Duplex STU Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ISO 13628-5 / API Spec 17E Super-Duplex STU Standard) | Zero dielectric breakdown and verified insulation resistance for 6/10 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO 13628-5 / API Spec 17E Super-Duplex STU Standard) | Verified submersion integrity, tensile load and thermal stability across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.