Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
SB-45027 300 V Polar Under-Ice & Hydrographic Array Aramid Electromechanical Cable featuring 24 awg stranded bare copper pairs (3×2) and polyurethane (pur) outer sheath (SB-45027 / Polar Subsea EM, 300 V, -40 to +80 °C).
Typical values for this cable type, based on SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
SB-45027 300 V Polar Under-Ice & Hydrographic Array Aramid Electromechanical Cable featuring 24 awg stranded bare copper pairs (3×2) and polyurethane (pur) outer sheath (SB-45027 / Polar Subsea EM, 300 V, -40 to +80 °C).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: SB-45027 E-M (SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification) featuring 24 awg stranded bare copper pairs (3×2), ai/pet foil + copper braid dual shield and polyurethane (pur) outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 24 AWG Stranded Bare Copper Pairs (3×2) | Three twisted pairs with low-capacitance PE insulation plus drain wire |
| 2 | AI/PET Foil + Copper Braid Dual Shield | 100% aluminum-polyester tape plus copper wire braid EMC shield |
| 3 | Braided Aramid Strength Member | High-tenacity aramid fiber braid for under-ice & mooring tension |
| 4 | Polyurethane (PUR) Outer Sheath | Low-temperature and hydrolysis-resistant black PUR jacket |
Built to SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification with 24 awg stranded bare copper pairs (3×2) and polyurethane (pur) outer sheath
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SB-45027 E-M Construction Schedule (−40…+80 °C) | |||||||
| SB-45027 E-M 4Pr / 8Ch | 4×2×24–20 AWG (or 8-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 11.2 | 175 | 12.5 | 90 | |
| SB-45027 E-M 8Pr / 16Ch | 8×2×22–18 AWG (or 16-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 16.4 | 340 | 24.0 | 130 | |
| SB-45027 E-M 16Pr / 24Ch | 16×2×18–16 AWG (or 24-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 24.8 | 690 | 35.0 | 195 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24–20 AWG (or 8-Ch Array) | 42.00 | 300 V (≤55 nF/km) | −40…+80 °C |
| 8×2×22–18 AWG (or 16-Ch Array) | 26.00 | 300 V (≤60 nF/km) | −40…+80 °C |
| 16×2×18–16 AWG (or 24-Ch Array) | 15.20 | 300 V (≤65 nF/km) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification) | Zero dielectric breakdown and verified insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (SB-45027 Polar Under-Ice & Hydrographic Aramid-Reinforced EM Cable Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.