Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
SC300 Series (LW / LWS / SAL / SAM / DA) 8,000m Deep-Sea 3-Divided Steel Segment Loose-Tube & TIG-Welded Copper Tube Repeatered Transoceanic Optical Submarine Cable (ITU-T G.976 / G.978, 12/20 kV, -10 °C to +60 °C).
Typical values for this cable type, based on ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard — confirmed in the datasheet and quotation for your order.
Application fit
SC300 Series (LW / LWS / SAL / SAM / DA) 8,000m Deep-Sea 3-Divided Steel Segment Loose-Tube & TIG-Welded Copper Tube Repeatered Transoceanic Optical Submarine Cable (ITU-T G.976 / G.978, 12/20 kV, -10 °C to +60 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: SC300 (LW / LWS / SAL / SAM / DA) (ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard) featuring dispersion-managed fibers (up to 16 dmf), 3-divided steel segment pipe & steel wires and armour package (sal 22×ø3.2 mm / lws / da) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Dispersion-Managed Fibers (Up to 16 DMF) | Loose stress-free DMF+/DMF– optical fibers in ≥78 MPa water-blocking gel |
| 2 | 3-Divided Steel Segment Pipe & Steel Wires | Three cold-formed steel arch segments + stranded high-strength steel wire layer |
| 3 | TIG-Welded Copper Tube (15 kV DC Feed) | Seam-welded & swaged copper tube conductor (≤0.8 Ω/km @ 3 °C) & H₂ barrier |
| 4 | High-Voltage PE Insulation (LW Core Ø20.4 mm) | Extruded polyethylene HV insulation forming the 8,000 m deep-sea LW cable |
| 5 | Armour Package (SAL 22ר3.2 mm / LWS / DA) | Galvanized steel armour wires (310–800 kN) + PE sheath & PP roving serving |
Built to ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard with dispersion-managed fibers (up to 16 dmf) and armour package (sal 22×ø3.2 mm / lws / da)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SC300 (LW / LWS / SAL / SAM / DA) Construction Schedule (−10…+60 °C) | |||||||
| SC300 4F Single-Mode OS2 | 4 × G.652.D / G.657.A2 SM (200 kpsi) | Hermetic / gel-filled optical core | 3.5 | 18 | 3.4 | 35 | |
| SC300 12F Single-Mode OS2 | 12 × G.652.D / G.657.A2 SM (200 kpsi) | Hermetic / gel-filled optical core | 9.8 | 145 | 18.0 | 98 | |
| SC300 24F Armoured Subsea | 24 × G.652.D SM + Strength Armour | Subsea pressure-resistant optical unit | 17.0 | 580 | 95.0 | 255 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × G.652.D / G.657.A2 SM (200 kpsi) | 0.35 | ≤0.35 dB/km @ 1310 nm | −10…+60 °C |
| 12 × G.652.D / G.657.A2 SM (200 kpsi) | 0.22 | ≤0.22 dB/km @ 1550 nm | −10…+60 °C |
| 24 × G.652.D SM + Strength Armour | 0.20 | ≤0.20 dB/km @ 1550 nm | −10…+60 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard) | Zero dielectric breakdown and verified insulation resistance for 12/20 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.976 / G.978 & UJC 8,000 m Transoceanic Standard) | Verified submersion integrity, tensile load and thermal stability across −10…+60 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.