S07RN8H2-F 450/750 V Ex-Area & Wastewater Flat Submersible Pump CableDIN EN 60079 / DIN 4045 · 450/750 V · Ex-hazard & wastewater cpe flat submersible pump

S07RN8H2-F 450/750 V (Ozone-Resistant AD8) EPR-Insulated CPE-Sheathed Ex-Area & Wastewater Flat Submersible Pump Rubber Cable (DIN EN 60079 / DIN 4045, 450/750 V, -25 °C to +80 °C, min. bend radius 6 × OD).

Water-resistant
Oil-resistant
Flame-retardant
Approved
Order designation
S07RN8H2-F 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
450/750 V
Tested per DIN EN 60079 / DIN 4045
Operating temp.
−25…+80 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3–4×1.5–185 mm²
Parallel Class 5 flexible bare Cu
Outer protection
Black Ex/Sewage
Oil-
Standard
DIN EN 60079
DIN EN 60079 Ex-Hazard & DIN 4045/4046

Typical values for this cable type, based on DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat — confirmed in the datasheet and quotation for your order.

Application fit

Is S07RN8H2-F right for your machine?

S07RN8H2-F 450/750 V (Ozone-Resistant AD8) EPR-Insulated CPE-Sheathed Ex-Area & Wastewater Flat Submersible Pump Rubber Cable (DIN EN 60079 / DIN 4045, 450/750 V, -25 °C to +80 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: S07RN8H2-F (DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat) featuring parallel class 5 bare copper (up to 185 mm²), water-resistant epr core insulation and oil & sewage resistant cpe flat sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Parallel Class 5 Bare Copper (Up to 185 mm²)DIN EN 60228 Class 5 flexible plain copper conductors arranged in flat profile
2Water-Resistant EPR Core InsulationCross-linked ethylene propylene rubber rated for +90 °C conductor / +250 °C short-circuit
3Oil & Sewage Resistant CPE Flat SheathBlack chlorinated polyethylene flat jacket (DIN EN 60079 Ex, EN 60811-404, 500–2,000 m)

S07RN8H2-F — Standard Subsea & Marine Execution

Built to DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat with parallel class 5 bare copper (up to 185 mm²) and oil & sewage resistant cpe flat sheath

S07RN8H2-F — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

S07RN8H2-F — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
450/750 V (DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat)
Core / conductor construction
Parallel Class 5 Bare Copper (Up to 185 mm²) — DIN EN 60228 Class 5 flexible plain copper conductors arranged in flat profile
Primary dielectric / buffering
Water-Resistant EPR Core Insulation — Cross-linked ethylene propylene rubber rated for +90 °C conductor / +250 °C short-circuit

Thermal

Continuous operating temperature
−25…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Oil & Sewage Resistant CPE Flat Sheath — Black chlorinated polyethylene flat jacket (DIN EN 60079 Ex, EN 60811-404, 500–2,000 m)
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Water-Resistant EPR Core Insulation — Cross-linked ethylene propylene rubber rated for +90 °C conductor / +250 °C short-circuit

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
S07RN8H2-F
Sheath colour & metre marking
Continuous metre-marked black outer finish (Black Ex/Sewage CPE Flat)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard S07RN8H2-F subsea & marine configurations

Manufactured to DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
S07RN8H2-F Construction Schedule (−25…+80 °C)
S07RN8H2-F 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
S07RN8H2-F 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
S07RN8H2-F 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat)DC resistance at 20 °C / optical attenuation and outer diameter within DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat)Zero dielectric breakdown and verified insulation resistance for 450/750 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat)Verified submersion integrity, tensile load and thermal stability across −25…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN EN 60079 / DIN 4045 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX S07RN8H2-F DIN EN 60079 / DIN 4045 450/750 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define S07RN8H2-F (S07RN8H2-F 450/750 V Ex-Area & Wastewater Flat Submersible Pump Cable)?
S07RN8H2-F (S07RN8H2-F 450/750 V Ex-Area & Wastewater Flat Submersible Pump Cable) is manufactured in accordance with DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat for 450/750 V service over -25 °C to +80 °C. Its 3-layer construction comprises parallel class 5 bare copper (up to 185 mm²), water-resistant epr core insulation and oil & sewage resistant cpe flat sheath.
What is the minimum bending radius and operating temperature range for S07RN8H2-F?
The minimum bending radius for S07RN8H2-F is 6 × OD across its continuous operating temperature range of -25 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of S07RN8H2-F arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Parallel Class 5 Bare Copper (Up to 185 mm²) — DIN EN 60228 Class 5 flexible plain copper conductors arranged in flat profile; (02) Water-Resistant EPR Core Insulation — Cross-linked ethylene propylene rubber rated for +90 °C conductor / +250 °C short-circuit; (03) Oil & Sewage Resistant CPE Flat Sheath — Black chlorinated polyethylene flat jacket (DIN EN 60079 Ex, EN 60811-404, 500–2,000 m).
What factory test certificates are supplied with S07RN8H2-F?
Every production drum of S07RN8H2-F undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN EN 60079 Ex-Hazard & DIN 4045/4046 Wastewater Flat, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for S07RN8H2-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S07RN8H2-F 450/750 V Ex-Area & Wastewater Flat Submersible Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 