S1BZ-F (2,000m HF) & VSCCB (500m EMC Screened) 0.6/1 kV Pump CableVDE 0282 / EMC VFD · 0.6/1 kV · 2,000 m halogen-free & 500 m emc screened vfd

S1BZ-F 0.6/1 kV (0.6/1 kV 2,000m HEPR/EPDM/EVA Halogen-Free Oil-Resistant Pump Cable) & VSCCB 0.6/1 kV (EMC Screened 500m Screened EPR VFD Wastewater Cable) (VDE 0282 / EMC VFD, 0.6/1 kV, -25 °C to +90 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Low-EMC design
Oil-resistant
Order designation
S1BZ-F 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per VDE 0282 / EMC VFD
Operating temp.
−25…+90 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3–4G 1.5–240 mm²
Class 5 bare/SnCu + HEPR
Outer protection
HF EVA/SnCu+EPR
Halogen-free EVA or SnCu braid + EPR
Standard
VDE 0282/EMC VFD
DIN VDE 0282

Typical values for this cable type, based on DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable — confirmed in the datasheet and quotation for your order.

Application fit

Is S1BZ-F & VSCCB right for your machine?

S1BZ-F 0.6/1 kV (0.6/1 kV 2,000m HEPR/EPDM/EVA Halogen-Free Oil-Resistant Pump Cable) & VSCCB 0.6/1 kV (EMC Screened 500m Screened EPR VFD Wastewater Cable) (VDE 0282 / EMC VFD, 0.6/1 kV, -25 °C to +90 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesMaterial Handling & Port Crane Equipment CableDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: S1BZ-F & VSCCB (DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable) featuring class 5 copper conductors (up to 240 mm²), 0.6/1 kv hepr / epr core insulation and tinned copper braid & oil-resistant sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Copper Conductors (Up to 240 mm²)Finely stranded plain copper (S1BZ-F) or tinned copper ≤6 mm² (VSCCB EMC Screened)
20.6/1 kV HEPR / EPR Core InsulationReduced-wall HEPR (S1BZ-F 0.6/1 kV) or EPR (VSCCB EMC Screened) rated +90 °C
3Waterproof Anti-Bubble Inner SheathSpecial EPDM / EPR inner sheath preventing osmotic water-bubble formation under pressure
4Tinned Copper Braid & Oil-Resistant SheathTinned Cu braid (VSCCB) + halogen-free oil-resistant EVA (2,000 m) or EPR (500 m) jacket

S1BZ-F & VSCCB — Standard Subsea & Marine Execution

Built to DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable with class 5 copper conductors (up to 240 mm²) and tinned copper braid & oil-resistant sheath

S1BZ-F & VSCCB — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

S1BZ-F & VSCCB — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable)
Core / conductor construction
Class 5 Copper Conductors (Up to 240 mm²) — Finely stranded plain copper (S1BZ-F) or tinned copper ≤6 mm² (VSCCB EMC Screened)
Primary dielectric / buffering
0.6/1 kV HEPR / EPR Core Insulation — Reduced-wall HEPR (S1BZ-F 0.6/1 kV) or EPR (VSCCB EMC Screened) rated +90 °C

Thermal

Continuous operating temperature
−25…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Tinned Copper Braid & Oil-Resistant Sheath — Tinned Cu braid (VSCCB) + halogen-free oil-resistant EVA (2,000 m) or EPR (500 m) jacket
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Waterproof Anti-Bubble Inner Sheath — Special EPDM / EPR inner sheath preventing osmotic water-bubble formation under pressure

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
S1BZ-F & VSCCB
Sheath colour & metre marking
Continuous metre-marked black outer finish (HF EVA (2km) / SnCu+EPR)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard S1BZ-F & VSCCB subsea & marine configurations

Manufactured to DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
S1BZ-F & VSCCB Construction Schedule (−25…+90 °C)
S1BZ-F 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
S1BZ-F 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
S1BZ-F 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable)DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable)Verified submersion integrity, tensile load and thermal stability across −25…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0282 / EMC VFD CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX S1BZ-F & VSCCB VDE 0282 / EMC VFD 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define S1BZ-F & VSCCB (S1BZ-F (2,000m HF) & VSCCB (500m EMC Screened) 0.6/1 kV Pump Cable)?
S1BZ-F & VSCCB (S1BZ-F (2,000m HF) & VSCCB (500m EMC Screened) 0.6/1 kV Pump Cable) is manufactured in accordance with DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable for 0.6/1 kV service over -25 °C to +90 °C. Its 4-layer construction comprises class 5 copper conductors (up to 240 mm²), 0.6/1 kv hepr / epr core insulation and tinned copper braid & oil-resistant sheath.
What is the minimum bending radius and operating temperature range for S1BZ-F & VSCCB?
The minimum bending radius for S1BZ-F & VSCCB is 6 × OD across its continuous operating temperature range of -25 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of S1BZ-F & VSCCB arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Copper Conductors (Up to 240 mm²) — Finely stranded plain copper (S1BZ-F) or tinned copper ≤6 mm² (VSCCB EMC Screened); (02) 0.6/1 kV HEPR / EPR Core Insulation — Reduced-wall HEPR (S1BZ-F 0.6/1 kV) or EPR (VSCCB EMC Screened) rated +90 °C; (03) Waterproof Anti-Bubble Inner Sheath — Special EPDM / EPR inner sheath preventing osmotic water-bubble formation under pressure; (04) Tinned Copper Braid & Oil-Resistant Sheath — Tinned Cu braid (VSCCB) + halogen-free oil-resistant EVA (2,000 m) or EPR (500 m) jacket.
What factory test certificates are supplied with S1BZ-F & VSCCB?
Every production drum of S1BZ-F & VSCCB undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN VDE 0282 / IEC 60811-404 2,000m HF & EMC Pump Cable, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for S1BZ-F & VSCCB

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S1BZ-F (2,000m HF) & VSCCB (500m EMC Screened) 0.6/1 kV Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 