Contact

S1RN8-F / S1RC4N8-F & S1BNH2-F 0.6/1 kV 3GI3/EM2 Submersible CableVDE 0207-20 / EN 50363 · 0.6/1 kV · 0.6/1 kv 3gi3 epr & em2 round/screened/flat

S1RN8-F (SUBMERSIBLE), S1RC4N8-F (SUBMERSIBLE S) & S1BNH2-F (Flat Submersible 300m Flat) 0.6/1 kV 3GI3 EPR-Insulated EM2 Rubber Submersible Pump Cable (VDE 0207-20 / EN 50363, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Oil-resistant
Flame-retardant
Order designation
S1RN8-F 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per VDE 0207-20 / EN 50363
Operating temp.
−25…+80 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3G–4G 1.5–185
Class 5 bare or SnCu+3GI3 EPR insulation
Outer protection
Black EM2
EN 50363-2-1 EM2 synthetic rubber
Standard
VDE 0207-20
VDE 0207-20 3GI3 & EN 50363-2-1 EM2

Typical values for this cable type, based on VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is S1RN8-F / S1RC4N8-F & S1BNH2-F right for your machine?

S1RN8-F (SUBMERSIBLE), S1RC4N8-F (SUBMERSIBLE S) & S1BNH2-F (Flat Submersible 300m Flat) 0.6/1 kV 3GI3 EPR-Insulated EM2 Rubber Submersible Pump Cable (VDE 0207-20 / EN 50363, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: S1RN8-F / S1RC4N8-F & S1BNH2-F (VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard) featuring class 5 copper conductors (bare / tinned), 3gi3 grade epr core insulation (0.6/1 kv) and black em2 submersible elastomer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Copper Conductors (Bare / Tinned)Class 5 bare Cu (S1RN8-F / S1RC4N8-F) or parallel tinned Cu in 300 m S1BNH2-F Flat Submersible
23GI3 Grade EPR Core Insulation (0.6/1 kV)VDE 0207-20 3GI3 cross-linked ethylene propylene rubber (4.0 kV test, +90 °C)
3Rubber Inner Sheath & Bare Copper Braid (C4)Extruded rubber inner sheath + bare copper wire braid screen on S1RC4N8-F SUBMERSIBLE S
4Black EM2 Submersible Elastomer SheathEN 50363-2-1 EM2 synthetic rubber jacket for 100 m (round) to 300 m (Flat Submersible) depth

S1RN8-F / S1RC4N8-F & S1BNH2-F — Standard Subsea & Marine Execution

Built to VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard with class 5 copper conductors (bare / tinned) and black em2 submersible elastomer sheath

S1RN8-F / S1RC4N8-F & S1BNH2-F — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

S1RN8-F / S1RC4N8-F & S1BNH2-F — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard)
Core / conductor construction
Class 5 Copper Conductors (Bare / Tinned) — Class 5 bare Cu (S1RN8-F / S1RC4N8-F) or parallel tinned Cu in 300 m S1BNH2-F Flat Submersible
Primary dielectric / buffering
3GI3 Grade EPR Core Insulation (0.6/1 kV) — VDE 0207-20 3GI3 cross-linked ethylene propylene rubber (4.0 kV test, +90 °C)

Thermal

Continuous operating temperature
−25…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Black EM2 Submersible Elastomer Sheath — EN 50363-2-1 EM2 synthetic rubber jacket for 100 m (round) to 300 m (Flat Submersible) depth
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Rubber Inner Sheath & Bare Copper Braid (C4) — Extruded rubber inner sheath + bare copper wire braid screen on S1RC4N8-F SUBMERSIBLE S

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
S1RN8-F / S1RC4N8-F & S1BNH2-F
Sheath colour & metre marking
Continuous metre-marked black outer finish (Black EM2 Elastomer)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard S1RN8-F / S1RC4N8-F & S1BNH2-F subsea & marine configurations

Manufactured to VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
S1RN8-F / S1RC4N8-F & S1BNH2-F Construction Schedule (−25…+80 °C)
S1RN8-F 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
S1RN8-F 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
S1RN8-F 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard)DC resistance at 20 °C / optical attenuation and outer diameter within VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard)Verified submersion integrity, tensile load and thermal stability across −25…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0207-20 / EN 50363 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX S1RN8-F / S1RC4N8-F & S1BNH2-F VDE 0207-20 / EN 50363 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define S1RN8-F / S1RC4N8-F & S1BNH2-F (S1RN8-F / S1RC4N8-F & S1BNH2-F 0.6/1 kV 3GI3/EM2 Submersible Cable)?
S1RN8-F / S1RC4N8-F & S1BNH2-F (S1RN8-F / S1RC4N8-F & S1BNH2-F 0.6/1 kV 3GI3/EM2 Submersible Cable) is manufactured in accordance with VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard for 0.6/1 kV service over -25 °C to +80 °C. Its 4-layer construction comprises class 5 copper conductors (bare / tinned), 3gi3 grade epr core insulation (0.6/1 kv) and black em2 submersible elastomer sheath.
What is the minimum bending radius and operating temperature range for S1RN8-F / S1RC4N8-F & S1BNH2-F?
The minimum bending radius for S1RN8-F / S1RC4N8-F & S1BNH2-F is 6 × OD across its continuous operating temperature range of -25 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of S1RN8-F / S1RC4N8-F & S1BNH2-F arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Copper Conductors (Bare / Tinned) — Class 5 bare Cu (S1RN8-F / S1RC4N8-F) or parallel tinned Cu in 300 m S1BNH2-F Flat Submersible; (02) 3GI3 Grade EPR Core Insulation (0.6/1 kV) — VDE 0207-20 3GI3 cross-linked ethylene propylene rubber (4.0 kV test, +90 °C); (03) Rubber Inner Sheath & Bare Copper Braid (C4) — Extruded rubber inner sheath + bare copper wire braid screen on S1RC4N8-F SUBMERSIBLE S; (04) Black EM2 Submersible Elastomer Sheath — EN 50363-2-1 EM2 synthetic rubber jacket for 100 m (round) to 300 m (Flat Submersible) depth.
What factory test certificates are supplied with S1RN8-F / S1RC4N8-F & S1BNH2-F?
Every production drum of S1RN8-F / S1RC4N8-F & S1BNH2-F undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per VDE 0207-20 3GI3 & EN 50363-2-1 EM2 Submersible Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for S1RN8-F / S1RC4N8-F & S1BNH2-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S1RN8-F / S1RC4N8-F & S1BNH2-F 0.6/1 kV 3GI3/EM2 Submersible Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp