Free-hanging vertical run
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
Product
S-3GSHCOEU 0.6/1 kV (IEC) & 1,000 V (UL 758) EMC-Screened LSZH Wind Turbine Torsion Cable (DIN VDE 0250 / UL 758) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification — confirmed in the datasheet and quotation for your order.
Application fit
S-3GSHCOEU 0.6/1 kV (IEC) & 1,000 V (UL 758) EMC-Screened LSZH Wind Turbine Torsion Cable (DIN VDE 0250 / UL 758) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.
Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.
Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.
Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.
Use Spreader Reel CableConstruction
Shown: S-3GSHCOEU 0.6/1 kV (DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification) featuring vde 0295 class 5 bare copper conductors, 3gi3 heat-resistant epr core insulation and 5gm5 halogen-free elastomer outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | VDE 0295 Class 5 Bare Copper Conductors | Flexible plain copper cores (1C, 3-5C power or multi-core control) |
| 2 | 3GI3 Heat-Resistant EPR Core Insulation | Cross-linked ethylene-propylene rubber rated 0.6/1 kV & UL 1000 V |
| 3 | Tinned Copper Wire Braid EMC Screen (SHC | Torsion-stabilized tinned copper braid shielding converter EMI |
| 4 | 5GM5 Halogen-Free Elastomer Outer Sheath | Flame-retardant thermoset jacket rated for ±150°/m yaw torsion |
Built to DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification with vde 0295 class 5 bare copper conductors and 5gm5 halogen-free elastomer outer sheath
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| S-3GSHCOEU 0.6/1 kV Construction Schedule (−40…+90 °C) | |||||||
| S-3GSHCOEU 0.6 4G16 / 3×16+3G2.5 | 4G16 mm² (or 3×6 AWG + 3G10 AWG) | IEC 60228 Class 5 / Class K Cu | 21.8 | 790 | 9.5 | 130 | |
| S-3GSHCOEU 0.6 4G50 / 3×50+3G10 | 4G50 mm² (or 3×1 AWG + 3G6 AWG) | IEC 60228 Class 5 / Class K Cu | 31.4 | 2,140 | 22.5 | 190 | |
| S-3GSHCOEU 0.6 3×150+3G25 VFD | 3×150 + 3G25 mm² (or 3×350 kcmil) | IEC 60228 Class 5 / Class K Cu | 47.2 | 5,480 | 58.0 | 285 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (or 3×6 AWG + 3G10 AWG) | 1.15 | 0.6/1 kV / 1,000 V (98 A VFD) | −40…+90 °C |
| 4G50 mm² (or 3×1 AWG + 3G6 AWG) | 0.39 | 0.6/1 kV / 1,000 V (195 A VFD) | −40…+90 °C |
| 3×150 + 3G25 mm² (or 3×350 kcmil) | 0.13 | 0.6/1 kV / 1,000 V (395 A VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV / 1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (DIN VDE 0250 & UL 758 AWM 1,000 V S-3GSHCOEU Screened Wind Torsion Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.