EN 50525 & HD 361 Industrial Rubber CablesHD 361 / EN 50525450/750 V & 0.6/1 kV+90 °C Halogen-Free EPR

S07BB-F / S1BB-F Heavy-Duty EPR-Insulated Industrial FlexibleEN 50525-2-21 / HD 361 · 450/750 V (S07BB-F) & 0.6/1 kV (S1BB-F) · +90 °C EPR/EPR · -40

S07BB-F (450/750 V) and S1BB-F (0.6/1 kV) are heavy-duty halogen-free industrial flexible rubber power cables featuring +90 °C cross-linked ethylene-propylene elastomer ('B') for both core insulation and outer sheathing. Compared with H07RN-F, they deliver

Outdoor & humid
Ozone, UV & moisture
Anti-torsion braid
Approved
Order designation
S07BB-F 5G2.5 (450/750 V)
Outer Ø ≈
14.2 mm
Copper weight
120 kg/km
Total weight ≈
272 kg/km
Min. bend R (fixed)
57 mm
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
450/750 & 0.6/1
S07BB-F (750 V) · S1BB-F (1000 V)
Conductor max.
+90 °C ('B')
Continuous · +250 °C short-circuit
Cold flexibility
-40 °C mobile
-50 °C fixed · Superior to PCP
Min. bend R
4 × D / 6 × D
Fixed installation / mobile flexing
Size range
1.5–185 mm²
1-core to 24-core configurations
Halogen status
100 % Halogen-f
EN 60754-1/2 EPR insulation & sheath

Typical values for this cable type, based on EN 50525-2-21 / HD 361 / VDE 0285 — confirmed in the datasheet and quotation for your order.

Application fit

Is S07BB-F / S1BB-F right for your machine?

Designed for cold-climate outdoor construction, wind turbine nacelles, alpine ski-lifts, refrigerating plants, stage and event power distribution, and +90 °C motor feeders.

Trailing & towing

Suitable

Remains supple down to -40 °C on outdoor construction sites, alpine machinery, and cold stores.

Festoon & line chain

Suitable

Excellent cold-weather and UV durability for outdoor crane festoons and gantry loops.

Motor stator, traction & converter leads

Suitable

+90 °C conductor rating handles high-ambient motor terminal boxes and wind-turbine generators.

Fixed installation

Suitable

Halogen-free EPR/EPR ('BB') construction is ideal for tunnels, metro works, and public buildings.

Motorised monospiral reel

With conditions

Suitable for spring-return drums up to 15 N/mm²; use NSHTÖU for heavy dynamic reeling.

NSHTÖU 0.6/1 kV
Typical machinesAlpine & Arctic ConstructionWind Turbine Tower & Nacelle PowerCold-Storage & Food Freezing PlantsTunnelling & Metro InfrastructureOutdoor Event & Broadcast Power

Construction

Layer by layer

Class 5 fine-stranded copper conductors with +90 °C cross-linked EPR insulation ('B', Type EI7) and a heavy-duty +90 °C halogen-free EPR

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible copper conductor ('-F')Class 5 fine-stranded plain or tinned annealed copper wireEN 60228 Class 5
2+90 °C EPR core insulation ('B')Cross-linked ethylene-propylene elastomer Type EI7 (EN 50363-1)EN 50363-1
3Short-pitch core lay-upCores stranded with short pitch and halogen-free elastomeric inner fillingEN 50525-2-21
4+90 °C EPR outer sheath ('B')Heavy-duty cross-linked ethylene-propylene elastomer Type EM7, halogen-free, UV- andEN 50363-2-1

S07BB-F (450/750 V)

Halogen-free +90 °C EPR/EPR upgrade to H07RN-F for cold-climate and high-ampacity portable equipment.

S1BB-F (0.6/1 kV)

Heavy-duty 0.6/1 kV +90 °C EPR/EPR power feeder for single-core and multi-core industrial distribution.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525-2-21 / HD 361 / VDE 0285. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage (S07BB-F / S1BB-F)
450/750 V AC / 0.6/1 kV AC
Routine AC test voltage
2.5 kV rms (S07) / 3.5 kV rms (S1)
Specific volume resistivity
≥ 10¹³ Ω·cm at +20 °C
Conductor stranding class
EN 60228 Class 5
Ampacity gain vs H07RN-F
+15 % to +18 % higher current rating
Operating frequency
50 / 60 Hz & DC

Thermal

Max. conductor operating temp.
+90 °C continuous ('B' EPR)
Max. short-circuit temperature
+250 °C (max. 5 s)
Mobile ambient range
-40 °C to +60 °C
Fixed ambient range
-50 °C to +80 °C
Min. laying temperature
-40 °C
Thermal ageing resistance
EN 50363-1/2 EI7 & EM7 rated

Mechanical

Min. bend radius (fixed)
4 × D (≤ 12 mm) / 5 × D (> 12 mm)
Min. bend radius (flexing)
6 × D (≤ 12 mm) / 8 × D (> 12 mm)
Max. dynamic tensile pull
15 N/mm² total copper cross-section
Cold-impact resilience
No cracking at -40 °C per EN 60811-506
Abrasion & tear resistance
Heavy-duty Type EM7 elastomer
Torsional stress (wind loop)
±100 °/m in vertical drip loops

Resistance

Halogen-free & low corrosivity
EN 60754-1/2 (< 0.5 % halogens)
Ozone & UV weather resistance
EN 60811-403 ozone-proof EPR
Water & moisture resistance
Low water absorption EPR compound
Sub-zero cold flexibility
Outperforms neoprene below -25 °C
Chemical splash
Resistant to weak acids & alkalis
RoHS / REACH status
CE & RoHS 3 compliant

Reference standards

Designation code system
CENELEC HD 361 S3 ('S07BB-F / S1BB-F')
Harmonised reference standard
EN 50525-2-21 (H07BB-F family)
Compound specification
EN 50363-1 (EI7) & EN 50363-2-1 (EM7)
Conductor standard
EN 60228 Class 5
Halogen test standard
EN 60754-1 / EN 60754-2
Quality certification
EN 10204 3.1 mill certificate

Identification

Core identification (≤ 5 cores)
HD 308 S2 colours (with G/Y)
Core identification (≥ 6 cores)
White numbers on black cores + G/Y
Outer sheath colour
Black
Surface marking
TEBAOFLEX S07BB-F / S1BB-F [n×mm²] +90C CE
Length marking
Sequential metre marking
Batch traceability
Lot number & year code

Sizes

12 standard configurations (S07BB-F / S1BB-F)

Nominal dimensions, copper weights and electrical parameters for S07BB-F / S1BB-F per EN 50525-2-21 / HD 361 / VDE 0285.

Dimensions & weights
Order designationType, Voltage & ConfigurationPhase size mm²Outer Ø ≈
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
S07BB-F (450/750 V) — Heavy-duty +90 °C EPR/EPR flexible rubber
S07BB-F 3G1.5 (450/750 V)450/750 V 3G1.51.59.84312239
S07BB-F 3G2.5 (450/750 V)450/750 V 3G2.52.511.67217846
S07BB-F 4G2.5 (450/750 V)450/750 V 4G2.52.512.89622251
S07BB-F 5G2.5 (450/750 V)450/750 V 5G2.52.514.212027257
S07BB-F 4G6.0 (450/750 V)450/750 V 4G6.06.016.823043067
S07BB-F 5G6.0 (450/750 V)450/750 V 5G6.06.018.628853074
S1BB-F (0.6/1 kV) — Extra-heavy 1000 V +90 °C EPR/EPR flexible rubber
S1BB-F 4G10 (0.6/1 kV)0.6/1 kV 4G101021.638473086
S1BB-F 4G16 (0.6/1 kV)0.6/1 kV 4G161624.86141,03099
S1BB-F 4G25 (0.6/1 kV)0.6/1 kV 4G252529.49601,520118
S1BB-F 4G35 (0.6/1 kV)0.6/1 kV 4G353533.01,3442,010132
S1BB-F 4G50 (0.6/1 kV)0.6/1 kV 4G505038.21,9202,760153
S1BB-F 1×95 (0.6/1 kV)0.6/1 kV 1×959522.09121,14088
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Outer diameters and weights are nominal factory values subject to ±5 % manufacturing tolerance per EN 50525-2-21 / HD 361 / VDE 0285.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC dielectric voltage test2.5 kV rms (S07BB-F) or 3.5 kV rms (S1BB-F) for 5 minutesEvery drum
Conductor DC resistanceComplies with EN 60228 Class 5 at 20 °CEvery drum
Sample tests
-40 °C cold-bend & cold-impact testNo cracking of EM7 EPR sheath or EI7 insulation at -40 °CPer batch
Halogen-free & +90 °C thermal ageing testPasses EN 60754-1/2 halogen test and EN 50363-1/2 ageingType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-21 / HD 361EN 60754-1/2CE / RoHS

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX S07BB-F / S1BB-F [n×mm²] +90C
Delivery form
Fumigated export wooden drums or coils
Standard drum lengths
500 m · 1000 m (or custom cut lengths)
MOQ
100 m (stock sizes) · 300–500 m (production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

How do S07BB-F and S1BB-F differ from standard H07RN-F rubber cable?
H07RN-F uses EPR insulation ('R') with a chlorinated polychloroprene outer sheath ('N') limited to -25 °C mobile flexing, whereas S07BB-F and S1BB-F use +90 °C cross-linked EPR ('B') for both insulation and outer sheath, delivering halogen-free safety, +90 °C conductor ampacity, and mobile cold flexibility down to -40 °C.
What is the difference between S07BB-F and S1BB-F?
S07BB-F is rated at 450/750 V AC (tested at 2.5 kV AC) in alignment with EN 50525-2-21 H07BB-F, while S1BB-F upgrades the radial insulation wall to a full 0.6/1 kV AC rating (tested at 3.5 kV AC) for heavy industrial and single-core power distribution.
When should S1BN8-F be selected instead of S1BB-F?
Select S1BN8-F whenever the cable operates in heavy mineral oils, diesel fuel, or AD8 permanent water submersion, as its polychloroprene ('N8') outer jacket offers higher hydrocarbon and flame resistance than halogen-free EPR ('B'). Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.
Is a screened version of S07BB-F / S1BB-F available for VFD motor connections?
Yes, S05BC4B-F, S07BC4B-F, and S1BC4B-F add an ≥ 85 % optical coverage tinned copper braid screen ('C4') between the inner bedding and the EPR outer sheath. Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.

Request a quote

Get an engineering quote for S07BB-F / S1BB-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S07BB-F / S1BB-F Heavy-Duty EPR-Insulated Industrial Flexible

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote