Contact

S07BBH2-F & S1BBH2-F 2,000m ELL/ACS Flat Drinking-Water Pump CableUBA ELL & ACS 2,000m · 0.6/1 kV · 2,000 m ell/acs potable-water epdm flat submersible

S07BBH2-F (450/750 V) & S1BBH2-F (0.6/1 kV) (AD8 Submersible) ELL/ACS Certified EPR/HEPR-Insulated EPDM-Sheathed 2,000m Flat Drinking-Water Submersible Pump Cable (UBA ELL & ACS 2,000m, 0.6/1 kV, -25 °C to +80 °C).

Water-resistant
Approved
Outdoor & humid
Ozone, UV & moisture
Order designation
S07BBH2-F 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per UBA ELL & ACS 2,000m
Operating temp.
−25…+80 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3–4×1.5–240 mm²
Parallel Class 5 bare Cu
Outer protection
Blue ELL/ACS
Extruded potable-water EPDM flat outer
Standard
UBA ELL & ACS
German UBA ELL & French ACS

Typical values for this cable type, based on German UBA ELL & French ACS / DIN EN 60228 Potable Flat — confirmed in the datasheet and quotation for your order.

Application fit

Is S07BBH2-F & S1BBH2-F right for your machine?

S07BBH2-F (450/750 V) & S1BBH2-F (0.6/1 kV) (AD8 Submersible) ELL/ACS Certified EPR/HEPR-Insulated EPDM-Sheathed 2,000m Flat Drinking-Water Submersible Pump Cable (UBA ELL & ACS 2,000m, 0.6/1 kV, -25 °C to +80 °C).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: S07BBH2-F & S1BBH2-F (German UBA ELL & French ACS / DIN EN 60228 Potable Flat) featuring parallel class 5 bare copper cores (3–4 flat), epr / reduced-wall hepr insulation and ell & acs potable-water epdm flat sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Parallel Class 5 Bare Copper Cores (3–4 Flat)DIN EN 60228 Class 5 flexible plain copper (up to 240 mm² in S07BBH2-F / 185 mm² in S1BBH2-F)
2EPR / Reduced-Wall HEPR InsulationEPR (450/750 V S07BBH2-F) or thin-wall high-modulus HEPR (0.6/1 kV S1BBH2-F)
3ELL & ACS Potable-Water EPDM Flat SheathFlat extruded EPDM outer sheath certified to German UBA ELL & French ACS down to 2,000 m

S07BBH2-F & S1BBH2-F — Standard Subsea & Marine Execution

Built to German UBA ELL & French ACS / DIN EN 60228 Potable Flat with parallel class 5 bare copper cores (3–4 flat) and ell & acs potable-water epdm flat sheath

S07BBH2-F & S1BBH2-F — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

S07BBH2-F & S1BBH2-F — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on German UBA ELL & French ACS / DIN EN 60228 Potable Flat. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (German UBA ELL & French ACS / DIN EN 60228 Potable Flat)
Core / conductor construction
Parallel Class 5 Bare Copper Cores (3–4 Flat) — DIN EN 60228 Class 5 flexible plain copper (up to 240 mm² in S07BBH2-F / 185 mm² in S1BBH2-F)
Primary dielectric / buffering
EPR / Reduced-Wall HEPR Insulation — EPR (450/750 V S07BBH2-F) or thin-wall high-modulus HEPR (0.6/1 kV S1BBH2-F)

Thermal

Continuous operating temperature
−25…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per German UBA ELL & French ACS / DIN EN 60228 Potable Flat
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
ELL & ACS Potable-Water EPDM Flat Sheath — Flat extruded EPDM outer sheath certified to German UBA ELL & French ACS down to 2,000 m
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
EPR / Reduced-Wall HEPR Insulation — EPR (450/750 V S07BBH2-F) or thin-wall high-modulus HEPR (0.6/1 kV S1BBH2-F)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per German UBA ELL & French ACS / DIN EN 60228 Potable Flat
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per German UBA ELL & French ACS / DIN EN 60228 Potable Flat
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
German UBA ELL & French ACS / DIN EN 60228 Potable Flat
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
S07BBH2-F & S1BBH2-F
Sheath colour & metre marking
Continuous metre-marked blue outer finish (Blue ELL/ACS EPDM Flat)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard S07BBH2-F & S1BBH2-F subsea & marine configurations

Manufactured to German UBA ELL & French ACS / DIN EN 60228 Potable Flat for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
S07BBH2-F & S1BBH2-F Construction Schedule (−25…+80 °C)
S07BBH2-F 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
S07BBH2-F 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
S07BBH2-F 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per German UBA ELL & French ACS / DIN EN 60228 Potable Flat.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (German UBA ELL & French ACS / DIN EN 60228 Potable Flat)DC resistance at 20 °C / optical attenuation and outer diameter within German UBA ELL & French ACS / DIN EN 60228 Potable Flat tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (German UBA ELL & French ACS / DIN EN 60228 Potable Flat)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (German UBA ELL & French ACS / DIN EN 60228 Potable Flat)Verified submersion integrity, tensile load and thermal stability across −25…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UBA ELL & ACS 2,000m CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX S07BBH2-F & S1BBH2-F UBA ELL & ACS 2,000m 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define S07BBH2-F & S1BBH2-F (S07BBH2-F & S1BBH2-F 2,000m ELL/ACS Flat Drinking-Water Pump Cable)?
S07BBH2-F & S1BBH2-F (S07BBH2-F & S1BBH2-F 2,000m ELL/ACS Flat Drinking-Water Pump Cable) is manufactured in accordance with German UBA ELL & French ACS / DIN EN 60228 Potable Flat for 0.6/1 kV service over -25 °C to +80 °C. Its 3-layer construction comprises parallel class 5 bare copper cores (3–4 flat), epr / reduced-wall hepr insulation and ell & acs potable-water epdm flat sheath.
What is the minimum bending radius and operating temperature range for S07BBH2-F & S1BBH2-F?
The minimum bending radius for S07BBH2-F & S1BBH2-F is 6 × OD across its continuous operating temperature range of -25 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of S07BBH2-F & S1BBH2-F arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Parallel Class 5 Bare Copper Cores (3–4 Flat) — DIN EN 60228 Class 5 flexible plain copper (up to 240 mm² in S07BBH2-F / 185 mm² in S1BBH2-F); (02) EPR / Reduced-Wall HEPR Insulation — EPR (450/750 V S07BBH2-F) or thin-wall high-modulus HEPR (0.6/1 kV S1BBH2-F); (03) ELL & ACS Potable-Water EPDM Flat Sheath — Flat extruded EPDM outer sheath certified to German UBA ELL & French ACS down to 2,000 m.
What factory test certificates are supplied with S07BBH2-F & S1BBH2-F?
Every production drum of S07BBH2-F & S1BBH2-F undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per German UBA ELL & French ACS / DIN EN 60228 Potable Flat, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for S07BBH2-F & S1BBH2-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S07BBH2-F & S1BBH2-F 2,000m ELL/ACS Flat Drinking-Water Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote