Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
RU(i) S11 / RU(c) S12 & BU(i) S13 250 V NEK 606 Unarmoured Mud-Resistant Offshore Instrumentation Cable (NEK TS 606 S11–S14) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376 — confirmed in the datasheet and quotation for your order.
Application fit
RU(i) S11 / RU(c) S12 & BU(i) S13 250 V NEK 606 Unarmoured Mud-Resistant Offshore Instrumentation Cable (NEK TS 606 S11–S14) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 6 × OD).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: RU(I) S11 / RU(C) S12 & BU(I) S13 250 V (NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376) featuring tinned copper epr pairs (6×2×0.75 mm²), individual & collective foil screen and shf2-mud mud-resistant outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper EPR Pairs (6×2×0.75 mm²) | Stranded tinned copper with 90 °C EPR insulation (plus mica in BU series) |
| 2 | Individual & Collective Foil Screen | Al/PET foil tape + tinned copper drain wire per pair and overall |
| 3 | Unarmoured Lightweight Design (S11–S14) | Reduced weight and bending radius for offshore cabinet & tray routing |
| 4 | SHF2-MUD Mud-Resistant Outer Jacket | Cross-linked thermoset elastomer resistant to drilling muds and oils |
Built to NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376 with tinned copper epr pairs (6×2×0.75 mm²) and shf2-mud mud-resistant outer jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RU(I) S11 / RU(C) S12 & BU(I) S13 250 V Construction Schedule (−40…+90 °C) | |||||||
| RU(I) S11 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| RU(I) S11 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| RU(I) S11 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code S11/S12 (RU) & S13/S14 (BU Fire-Resistant) / IEC 60092-376) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.