MIL-DTL-17 PE/PVC RF Coaxial CablesMIL-DTL-17/74 RG-21350 Ω · 3700 V rmsØ 10.30 mm (0.405") Feeder

RG-213 RF Coaxial CableMIL-DTL-17/74 · 50 Ω ± 2 Ω · Ø 10.30 mm · 13 AWG (7×0.75) bare Cu · Solid PE · 96 % Cu

RG-213 (RG-213/U, MIL-DTL-17/74-RG213 and M17/163-00001) is the standard 50 Ω heavy-duty RF coaxial transmission cable (Ø 10.30 mm / 0.405 in) for HF/VHF/UHF base-station antennas, marine shipboard VHF/AIS feeders, and broadcast transmitters up to 1000 MHz.

EMC screen
Low-EMC design
Outdoor & humid
Flame-retardant
Order designation
RG-213/U (M17/74-RG213) Type IIA PVC
Outer Ø ≈
10.30 mm
Metal weight
74.0 kg/km
Total weight ≈
156.0 kg/km
Min. bend R (fixed)
52 mm
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Impedance Z₀
50 Ω ± 2 Ω
MIL-DTL-17/74 base-station coax
Outer diameter
10.30 mm (0.405
Standard Type N / UHF PL-259 size
Center conductor
13 AWG (7×0.75
3.09 mm² stranded bare copper
Velocity / Cap.
66 % · 101 pF/m
Solid PE dielectric Ø 7.24 mm
Max. voltage
3700 V rms
10.0 kV rms dielectric test
Temp. rating
-40 to +80 °C
Non-contaminating PVC Type IIA

Typical values for this cable type, based on MIL-DTL-17/74-RG213 (M17/163-00001) — confirmed in the datasheet and quotation for your order.

Application fit

Is RG-213 right for your machine?

Engineered for outdoor antenna masts, marine VHF/AIS/radar installations, HF/VHF amateur and commercial transmitter feeders, and industrial RF plasma generators.

Fixed installation

Suitable

UV-stabilised non-contaminating PVC Type IIA (or PE/LSZH) jacket built for outdoor tower and shipboard mast routing.

Switchgear & control cabinet wiring

Suitable

3,700 V rms working voltage handles high-power HF/VHF transmitter racks and RF matching networks.

Trailing & towing

With conditions

7×0.75 mm stranded conductor allows tactical field reel deployment at ≥ 50 mm bend radius.

Energy chain / drag chain

Not suitable

Ø 10.3 mm solid-PE feeder coax is not designed for continuous linear drag chains.

S 368 C
Typical machinesHF / VHF / UHF Base Station FeedersMarine VHF, AIS & Shipboard CommsLand Mobile & Emergency Dispatch TowersIndustrial RF Heating & Plasma SupplyMilitary Tactical Antenna Masts

Construction

Layer by layer

13 AWG (7×0.75 mm) bare copper center conductor, Ø 7.24 mm solid polyethylene dielectric, ≥ 96 % bare copper braid, and Ø 10.30 mm black

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded bare copper center (13 AWG)7 × 0.75 mm (Ø 2.26 mm, 3.09 mm²) annealed high-conductivity bare copper per ASTM B3MIL-DTL-17/74
2Solid polyethylene (PE) dielectricVirgin low-loss solid polyethylene Type A, Ø 7.24 mm ± 0.18 mm (0.285 in)MIL-DTL-17/74
3High-coverage bare copper braid34 AWG annealed bare copper wire braid with ≥ 96 % optical coverageMIL-DTL-17/74
4Non-contaminating PVC Type IIA jacketUV-resistant black polyvinyl chloride Type IIA (or LSZH / direct-burial PE), Ø 10.30 mmMIL-DTL-17/74

RG-213/U (M17/74-RG213 / M17/163)

Standard MIL-DTL-17 construction with non-contaminating black PVC Type IIA jacket.

RG-213-LSZH (Marine Shipboard)

Halogen-free low-smoke zero-halogen jacket per IEC 60332-3 and IEC 60754-1/2.

RG-213-PE (Direct Burial)

High-density polyethylene outer sheath for underground conduit and direct-burial antenna runs.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on MIL-DTL-17/74-RG213 (M17/163-00001). Values for your order are confirmed in the datasheet and quotation.

Electrical

Characteristic impedance Z₀
50 Ω ± 2 Ω
Nominal capacitance
101.0 pF/m (30.8 pF/ft)
Velocity of propagation (VoP)
66.0 %
Center / shield DC resistance
≤ 5.7 Ω/km / ≤ 3.9 Ω/km at 20 °C
Max. operating voltage
3,700 V rms (5,000 V rms peak)
Dielectric withstand test
10.0 kV rms at 60 Hz

Thermal

Operating temperature range
-40 °C to +80 °C
Installation temperature range
-20 °C to +70 °C
Dielectric softening limit
+85 °C (solid PE)
Flame retardance
IEC 60332-1-2 / UL VW-1
Cold-bend rating
-40 °C per MIL-DTL-17
Continuous CW power @ 100 MHz
1,400 W (@ +40 °C ambient)

Mechanical

Center conductor stranding
7 × 0.75 mm (13 AWG, Ø 2.26 mm)
Dielectric diameter
7.24 mm ± 0.18 mm (0.285 in)
Outer jacket diameter
10.30 mm ± 0.18 mm (0.405 in)
Min. bend radius (fixed / flex)
50 mm (5×D) / 100 mm (10×D)
Nominal cable weight
156.0 kg/km (105 lb/1000 ft)
Connector compatibility
Type N, UHF (PL-259), BNC, TNC, 7/16 DIN

Resistance

Plasticizer non-contamination
MIL Type IIA non-migrating PVC
UV & outdoor weather
Carbon-black UV-stabilised outer sheath
Moisture & salt-mist
Marine-grade jacket prevents water ingress
Crush & abrasion resistance
Thick 1.1 mm outer sheath wall
LSZH shipboard option
IEC 60754-1/2 & IEC 61034
RoHS / REACH status
RoHS 3 compliant

Reference standards

Military detail specification
MIL-DTL-17/74-RG213 & M17/163-00001
Superseded military code
MIL-C-17 RG-8/U (replaced by RG-213)
Conductor standard
ASTM B3 annealed bare copper
Flame test standard
IEC 60332-1-2
Coaxial RF standard
IEC 61196-1
Quality certification
EN 10204 3.1 + sweep return-loss report

Identification

Dielectric colour
Translucent natural solid PE
Outer jacket colour
Black
Surface legend
TEBAOFLEX MIL-DTL-17/74-RG213 50 OHM
Standard drum lengths
100 m, 305 m, 500 m, 1000 m
Impedance group
50 Ω 0.405" feeder coax
Batch traceability
Lot number & metre marking

Sizes

4 standard configurations (RG-213)

Dimensional, physical and high-frequency electrical parameters for RG-213 per MIL-DTL-17/74-RG213 (M17/163-00001).

Dimensions & construction
Order designationConstruction / VariantConductorOuter Ø ≈
mm
Metal
kg/km
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
Standard RG-213 variants
RG-213/U (M17/74-RG213) Type IIA PVC50 Ω 96% Bare Cu Braid (PVC)13 AWG (7×0.75 Cu)10.3074.0156.052
RG-213-LSZH Marine Halogen-Free50 Ω 96% Bare Cu Braid (LSZH)13 AWG (7×0.75 Cu)10.3074.0162.052
RG-213-PE Direct-Burial Polyethylene50 Ω 96% Bare Cu Braid (HDPE)13 AWG (7×0.75 Cu)10.3074.0144.052
RG-214/U Double-Shielded Silver-Plated50 Ω Dual SPC Braid (PVC)13 AWG (7×0.75 SPC)10.80112.0195.054
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal production values subject to manufacturing tolerances per MIL-DTL-17/74-RG213 (M17/163-00001).

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Sweep structural return loss (10–1000 MHz)50 Ω ± 2 Ω; return loss ≥ 21 dB across VHF/UHF bandsEvery drum
10.0 kV AC dielectric withstand test10.0 kV rms at 60 Hz without breakdownEvery drum
Sample tests
Jacket non-contamination & attenuation testZero dielectric tan δ degradation; MIL-DTL-17/74 lossPer batch
-40 °C cold-bend & UV weatherometerNo cracking after cold bend and accelerated UV exposureQualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

MIL-DTL-17/74-RG213IEC 60332-1-2RoHS 3 / CE

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MIL-DTL-17/74-RG213 50 OHM [Lot]
Delivery form
Spools, reels or export wooden drums
Standard reel lengths
100 m · 305 m (1000 ft) · 500 m · 1000 m
MOQ
100 m (stock) · 305–500 m (production)
Lead time
1–3 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

Why did MIL-DTL-17 replace RG-8/U with RG-213/U?
Early RG-8/U cables used standard PVC jackets whose plasticizers migrated into the polyethylene dielectric over time, increasing RF loss; RG-213/U mandates a non-contaminating Type IIA PVC jacket and tighter dimensional tolerances under MIL-DTL-17/74. Each production reel undergoes sweep-frequency impedance and return-loss verification, dielectric spark testing, and dimensional inspection before dispatch with an EN 10204 3.1 test certificate.
When should RG-214 be specified instead of RG-213?
Specify RG-214 when operating above 1 GHz (up to 11 GHz), in high-EMI transmitter rooms, or in corrosive marine environments—RG-214 upgrades both the 13 AWG center conductor and dual outer braids to silver-plated copper. Each production reel undergoes sweep-frequency impedance and return-loss verification, dielectric spark testing, and dimensional inspection before dispatch with an EN 10204 3.1 test certificate.
How much RF transmitter power can RG-213 handle?
Thanks to its 7.24 mm solid PE dielectric (3,700 V rms rating) and 3.09 mm² copper conductor, RG-213 handles up to 4.8 kW continuous CW at 10 MHz, 1.4 kW at 100 MHz (VHF), and 620 W at 400 MHz (UHF). Each production reel undergoes sweep-frequency impedance and return-loss verification, dielectric spark testing, and dimensional inspection before dispatch with an EN 10204 3.1 test certificate.
Which standard connectors fit RG-213?
All standard 0.405-inch (10.3 mm) coaxial connectors fit RG-213, including Type N (UG-21), UHF PL-259, 7/16 DIN, BNC, and TNC clamp or crimp plugs. Each production reel undergoes sweep-frequency impedance and return-loss verification, dielectric spark testing, and dimensional inspection before dispatch with an EN 10204 3.1 test certificate.

Request a quote

Get an engineering quote for RG-213

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

RG-213 RF Coaxial Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote