VFD inverter to AC motor screened feeder
Symmetrical 3+3E split-earth geometry and dual 100% foil + copper braid screen contain PWM inverter common-mode currents.
Product
RFOU-VFD P18 & RU-VFD 0.6/1 kV & 1.8/3 kV (Type P) Symmetrical 3+3E EPR-Insulated Dual-EMC-Screened SHF2 Mud-Resistant Offshore VFD Motor Cable (NEK TS 606 P18 / IEC 60092-353, 0.6/1 kV – 1.8/3 kV, -40 to +90 °C).
Typical values for this cable type, based on NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD — confirmed in the datasheet and quotation for your order.
Application fit
RFOU-VFD P18 & RU-VFD 0.6/1 kV & 1.8/3 kV (Type P) Symmetrical 3+3E EPR-Insulated Dual-EMC-Screened SHF2 Mud-Resistant Offshore VFD Motor Cable (NEK TS 606 P18 / IEC 60092-353, 0.6/1 kV – 1.8/3 kV, -40 to +90 °C).
Symmetrical 3+3E split-earth geometry and dual 100% foil + copper braid screen contain PWM inverter common-mode currents.
Low phase capacitance and transfer impedance prevent bearing currents and voltage reflection spikes on variable-speed motors.
SHF2-MUD or IEEE 1580 Type P XL-CPE jacket resists oil-based drilling mud, ester fluids and marine weathering.
Qualified for high-power drawworks, top drives, mud pumps and dynamic-positioning (DP) thruster drives.
Fixed VFD propulsion and rig feeder cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: RFOU-VFD P18 & RU-VFD 0.6/1-1.8/3 KV (NEK 606) (NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD) featuring tinned copper phase cores (3×95 mm² epr), 3+3e symmetrical split earth (3g16 mm²) and shf2-mud offshore outer sheath (p18) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Phase Cores (3×95 mm² EPR) | 1.8/3 kV corona-resistant EPR insulation withstanding PWM voltage spikes |
| 2 | 3+3E Symmetrical Split Earth (3G16 mm²) | Three interstitial earth conductors balancing common-mode currents |
| 3 | Dual EMC Screen (Copper Tape + TCWB) | 100% copper-backed tape + tinned copper wire braid over SHF2 inner sheath |
| 4 | SHF2-MUD Offshore Outer Sheath (P18) | NEK TS 606 oil- and ester-mud resistant cross-linked elastomer jacket |
Built to NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD with tinned copper phase cores (3×95 mm² epr) and shf2-mud offshore outer sheath (p18)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RFOU-VFD P18 & RU-VFD 0.6/1-1.8/3 KV (NEK 606) Construction Schedule (−40…+90 °C) | |||||||
| RFOU-VFD P18 3×35+3G6 VFD | 3 × 35 + 3G6 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 29.4 | 1,760 | 15.8 | 235 | |
| RFOU-VFD P18 3×70+3G10 VFD | 3 × 70 + 3G10 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 37.8 | 3,190 | 31.5 | 305 | |
| RFOU-VFD P18 3×120+3G16 VFD | 3 × 120 + 3G16 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 46.5 | 5,120 | 54.0 | 375 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 35 + 3G6 mm² (3+3E EMC) | 0.52 | 0.6/1 kV – 1.8/3 kV (138 A VFD) | −40…+90 °C |
| 3 × 70 + 3G10 mm² (3+3E EMC) | 0.27 | 0.6/1 kV – 1.8/3 kV (215 A VFD) | −40…+90 °C |
| 3 × 120 + 3G16 mm² (3+3E EMC) | 0.15 | 0.6/1 kV – 1.8/3 kV (305 A VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV – 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code P18 (RFOU-VFD) & RU-VFD / IEC 60092-353 SHF2-MUD) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking