Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
RFOU(i) S1/S5/S101 & RFOU(c) S2/S6/S102 150/250(300) V (Type P) EPR-Insulated Individually/Collectively Screened TCWB-Armoured SHF2 Mud-Resistant Offshore Instrumentation Cable (NEK TS 606 S1/S5 & S2/S6, 150/250 V, -40 to +90 °C).
Typical values for this cable type, based on NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD — confirmed in the datasheet and quotation for your order.
Application fit
RFOU(i) S1/S5/S101 & RFOU(c) S2/S6/S102 150/250(300) V (Type P) EPR-Insulated Individually/Collectively Screened TCWB-Armoured SHF2 Mud-Resistant Offshore Instrumentation Cable (NEK TS 606 S1/S5 & S2/S6, 150/250 V, -40 to +90 °C).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: RFOU(I) S1/S5 & RFOU(C) S2/S6 250 V (NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD) featuring epr instrumentation triads (4×3×1.5 mm²), individual foil screen & drain (rfou(i)) and grey shf2-mud outer sheath (s1/s5) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | EPR Instrumentation Triads (4×3×1.5 mm²) | Tinned copper Class 2/5 conductors with Black, White, Red EPR insulation |
| 2 | Individual Foil Screen & Drain (RFOU(i)) | Laminated Al/Cu-PET tape + tinned copper drain wire on each triad/pair |
| 3 | SHF2 Thermoset Inner Sheath | Halogen-free flame-retardant elastomeric inner bedding |
| 4 | Tinned Copper Wire Braid (TCWB) | Braided tinned copper wire armour for mechanical and EMI protection |
| 5 | Grey SHF2-MUD Outer Sheath (S1/S5) | NEK TS 606 mud-resistant thermoset jacket (Grey standard / Blue Ex-i) |
Built to NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD with epr instrumentation triads (4×3×1.5 mm²) and grey shf2-mud outer sheath (s1/s5)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RFOU(I) S1/S5 & RFOU(C) S2/S6 250 V Construction Schedule (−40…+90 °C) | |||||||
| RFOU(I) S1 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| RFOU(I) S1 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| RFOU(I) S1 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code S1/S5/S101 & S2/S6/S102 / IEC 60092-376 SHF2-MUD) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.