Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
RFE-HF, RFE-SHF2 & RFE-HF(i) 150/250 V (300 V) IEC 60092-376 XLPE-Insulated Copper-Wire-Braid Armoured & Screened SHF1/SHF2 Shipboard & Offshore Pair Instrumentation Cable (IEC 60092-376, 150/250 V, -40 to +90 °C).
Typical values for this cable type, based on IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
RFE-HF, RFE-SHF2 & RFE-HF(i) 150/250 V (300 V) IEC 60092-376 XLPE-Insulated Copper-Wire-Braid Armoured & Screened SHF1/SHF2 Shipboard & Offshore Pair Instrumentation Cable (IEC 60092-376, 150/250 V, -40 to +90 °C).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: RFE-HF & RFE-SHF2 / RFE-HF(I) 250 V (IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) featuring xlpe twisted pairs (4×2×0.75 mm²), individual & collective foil screen and shf1 / oil-resistant shf2 outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | XLPE Twisted Pairs (4×2×0.75 mm²) | Stranded copper conductors with numbered Blue/White XLPE insulation |
| 2 | Individual & Collective Foil Screen | Pair Al/PET foil + drain (RFE-HF(i)) and collective copper/PET tape |
| 3 | Copper Wire Braid Armour (RFE) | Tinned or bare copper wire braid mechanical armour and EMC screen |
| 4 | SHF1 / Oil-Resistant SHF2 Outer Jacket | Halogen-free polyolefin (RFE-HF) or cross-linked elastomer (RFE-SHF2) |
Built to IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A with xlpe twisted pairs (4×2×0.75 mm²) and shf1 / oil-resistant shf2 outer jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RFE-HF & RFE-SHF2 / RFE-HF(I) 250 V Construction Schedule (−40…+90 °C) | |||||||
| RFE-HF 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| RFE-HF 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| RFE-HF 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-376 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ