Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 57942 (Multipaires Sonar) 600 V 28×2×0.34 mm² (40-Ohm) Individually Spun-Copper-Shielded & Jacketed Pairs with Overall Copper Braid PUR Ship Sonar Dynamic Cable (40 Ω Naval Sonar, 600 V, -30 °C to +70 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard — confirmed in the datasheet and quotation for your order.
Application fit
REF 57942 (Multipaires Sonar) 600 V 28×2×0.34 mm² (40-Ohm) Individually Spun-Copper-Shielded & Jacketed Pairs with Overall Copper Braid PUR Ship Sonar Dynamic Cable (40 Ω Naval Sonar, 600 V, -30 °C to +70 °C, min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 57942 (MULTIPAIRES SONAR) (Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard) featuring 40 ω sonar twisted pairs (28×2×0.34 mm²), individual spun-copper shield & jacket and dynamic polyurethane sheath (ø25 ± 1 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 40 Ω Sonar Twisted Pairs (28×2×0.34 mm²) | Extra-flexible tinned copper + 600 V polyester elastomer (40±5 Ω, ≤180 pF/m) |
| 2 | Individual Spun-Copper Shield & Jacket | Each of the 28 pairs has a tinned copper spun shield and polyester elastomer sheath |
| 3 | Concentric 28-Pair Lay-Up (4 + 10 + 14) | Three concentric layers of individually jacketed coaxial-grade balanced pairs |
| 4 | Overall Tinned Copper Braid Shield | High-coverage overall tinned copper wire braid for sonar receiver EMC isolation |
| 5 | Dynamic Polyurethane Sheath (Ø25 ± 1 mm) | Black extra-flexible polyurethane (PUR) outer jacket (–30 °C to +70 °C, 740 g/m) |
Built to Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard with 40 ω sonar twisted pairs (28×2×0.34 mm²) and dynamic polyurethane sheath (ø25 ± 1 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 57942 (MULTIPAIRES SONAR) Construction Schedule (−30…+70 °C) | |||||||
| REF 57942 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 57942 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 57942 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (Naval 40 ± 5 Ω Controlled-Impedance Dynamic Sonar Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.