Immersion & wet locations
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60092-350 / ISO 13628-5.
Product
REF 56427 600 V subsea instrumentation cable comprising 4 individually screened triads of 1.34 mm² (16 AWG) tinned copper with ETFE insulation, galvanized steel wire armour and a black HDPE outer sheath.
Typical values for this cable type, based on IEC 60092-350 / ISO 13628-5 — confirmed in the datasheet and quotation for your order.
Application fit
REF 56427 600 V subsea instrumentation cable comprising 4 individually screened triads of 1.34 mm² (16 AWG) tinned copper with ETFE insulation, galvanized steel wire armour and a black HDPE outer sheath.
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60092-350 / ISO 13628-5.
Suitable for subsea winch deployment, LARS sheaves and vertical marine suspension within 8–12 × OD.
Verified for fixed subsea structure routing, deck jumpers and seabed interconnections.
Not intended for high-cycle dry factory drag chains; select a dedicated拖链/drag-chain cable for indoor automation.
Subsea ROV Main Lift UmbilicalConstruction
Shown: REF 56427 (IEC 60092-350 / ISO 13628-5) featuring stranded tinned copper triad conductors, etfe fluoropolymer core insulation and high-density polyethylene (hdpe) outer sheath (6-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Tinned Copper Triad Conductors | 12 x 1.34 mm² (4 triads x 3 cores, 16 AWG) stranded tinned copper conductors for corrosion-free marine signal transmissionIEC 60092-350 / ISO 13628-5 |
| 2 | ETFE Fluoropolymer Core Insulation | Thin-wall ethylene tetrafluoroethylene (ETFE) fluoropolymer insulation (White, Blue, Brown per triad) rated 600 VIEC 60092-350 / ISO 13628-5 |
| 3 | Individual Tinned Copper Braid Screen & ETFE Triad Jacket | Each triad individually shielded with a tinned copper wire braid (>= 85% coverage) and jacketed in an white ETFE sub-sheathIEC 60092-350 / ISO 13628-5 |
| 4 | Polyethylene (PE) Water-Blocking Inner Sheath | Extruded black polyethylene (PE) inner bedding sheath unifying the four screened triads under hydrostatic pressureIEC 60092-350 / ISO 13628-5 |
| 5 | Stainless Steel Wire Braid Armour | Full-coverage austenitic stainless steel (AISI 316) woven wire braid armour for subsea mechanical and bite protectionIEC 60092-350 / ISO 13628-5 |
| 6 | High-Density Polyethylene (HDPE) Outer Sheath | Heavy-duty black high-density polyethylene (HDPE) outer jacket for deepwater immersion and abrasion resistanceIEC 60092-350 / ISO 13628-5 |
Built to IEC 60092-350 / ISO 13628-5 with stranded tinned copper triad conductors and high-density polyethylene (hdpe) outer sheath
Available in continuous subsea winch lengths or factory-moulded / socket-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, optical & hydrostatic test report
Technical data
Sizes
Manufactured to IEC 60092-350 / ISO 13628-5 for deep-water ROV, towed array, mooring and subsea production systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight in air ≈ kg/km | Breaking load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 56427 Subsea Construction Schedule (−40…+90 °C) | |||||||
| REF 56427 4×3×1.34 mm² | 4 × 3 × 1.34 mm² (16 AWG) | 19 × 0.30 mm tinned Cu | 16.8 | 465 | 14.0 | 135 | |
| REF 56427 2×3×1.34 mm² | 2 × 3 × 1.34 mm² (16 AWG) | 19 × 0.30 mm tinned Cu | 13.4 | 310 | 9.5 | 110 | |
| REF 56427 7×3×1.34 mm² | 7 × 3 × 1.34 mm² (16 AWG) | 19 × 0.30 mm tinned Cu | 20.6 | 690 | 21.0 | 165 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 3 × 1.34 mm² (16 AWG) | 14.20 | 600 V RMS / 2000 V test | −40…+90 °C |
| 2 × 3 × 1.34 mm² (16 AWG) | 14.20 | 600 V RMS / 2000 V test | −40…+90 °C |
| 7 × 3 × 1.34 mm² (16 AWG) | 14.20 | 600 V RMS / 2000 V test | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR & dimensional verification (IEC 60092-350 / ISO 13628-5) | Electrical resistance, optical attenuation at 1310/1550 nm and OD within IEC 60092-350 / ISO 13628-5 tolerances | Every manufactured drum / assembly |
| High-voltage dielectric & insulation resistance test (IEC 60092-350 / ISO 13628-5) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / assembly |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & bend-over-sheave qualification (IEC 60092-350 / ISO 13628-5) | Verified structural and transmission integrity under deep-water pressure and tensile cycling across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.