Motorised monospiral reel
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-813 / IEC 60794-1-2 within 10 × OD.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / IEC 60794-1-2 across -25 to +80 °C.
Typical values for this cable type, based on DIN VDE 0250-813 / IEC 60794-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / IEC 60794-1-2 across -25 to +80 °C.
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-813 / IEC 60794-1-2 within 10 × OD.
Suitable for mobile mining loader, shuttle car and excavator trailing service across -25 to +80 °C.
Verified for underground mining galleries, tunnel faces and open-cast haulage paths.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: R-(N)TSCGEWÖU + FO (DIN VDE 0250-813 / IEC 60794-1-2) featuring phase conductors (3×50 mm²), split earth cores (2×25/2 mm²) and outer sheath (5gm5 red) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×50 mm²) | DIN VDE 0295 Class 5 flexible tinned copper + triple-extruded 3GI3 EPR |
| 2 | Split Earth Cores (2×25/2 mm²) | Two tinned copper earth conductors with semiconductive covering in interstices |
| 3 | Fiber-Optic Module (A-D(ZN)13Y 12FO) | Crush-resistant optical unit in 3rd interstice with 12 SM/MM fibres |
| 4 | 5GM3 Inner Sheath & Polyamide Braid | Black 5GM3 thermosetting inner sheath + polyamide anti-torsion braid |
| 5 | Outer Sheath (5GM5 Red) | Heavy-duty red crosslinked polychloroprene rubber outer jacket |
Built to DIN VDE 0250-813 / IEC 60794-1-2 with phase conductors (3×50 mm²) and outer sheath (5gm5 red)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to DIN VDE 0250-813 / IEC 60794-1-2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| R-(N)TSCGEWÖU + FO Construction Schedule (-25 to +80 °C) | |||||||
| R-(N)TSCGEWÖU 3×35 + 2×25/2 + 12FO 6/10 kV | 3×35 + 2×25/2 + 12×SM/MM FO | Class 5 tinned Cu + 12FO | 46.5 | 3,080 | 2.1 | 465 | |
| R-(N)TSCGEWÖU 3×50 + 2×25/2 + 12FO 6/10 kV | 3×50 + 2×25/2 + 12×SM/MM FO | Class 5 tinned Cu + 12FO | 50.4 | 3,740 | 3.0 | 505 | |
| R-(N)TSCGEWÖU 3×70 + 2×35/2 + 18FO 6/10 kV | 3×70 + 2×35/2 + 18×SM/MM FO | Class 5 tinned Cu + 18FO | 55.2 | 4,690 | 4.2 | 555 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×35 + 2×25/2 + 12×SM/MM FO | 0.57 | 6/10 kV (169 A) + 12F Optical | -25 to +80 °C |
| 3×50 + 2×25/2 + 12×SM/MM FO | 0.39 | 6/10 kV (206 A) + 12F Optical | -25 to +80 °C |
| 3×70 + 2×35/2 + 18×SM/MM FO | 0.28 | 6/10 kV (255 A) + 18F Optical | -25 to +80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-813 / IEC 60794-1-2) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-813 / IEC 60794-1-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-813 / IEC 60794-1-2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250-813 / IEC 60794-1-2) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.