Contact

R-(N)TSCGEWTOEUS 6/10 kV Anti-Torsion MV Reeling CableR-(N)TSCGEWTOEUS 6/10 kV heavy-duty medium-voltage reeling cable per DIN VDE 0250-813 for open-cast excavators, stacker-reclaimers and draglines, with Class 5 tinned copper phases, 3GI3 EPR insulation, 3 split earths, anti-torsion braid and 5GM5 sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / DIN VDE 0295 across -25 to +80 °C.

Anti-torsion braid
EMC screen
Oil-resistant
Flame-retardant
Order designation
R-(N)TSCGEWTOEUS 3×50 + 3×25/3 6/10 kV
Outer Ø ≈
48.2 mm
Net weight ≈
3,540 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Class 5 tinned Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10 kV
6/10 kV (3.6/6 to 18/30 kV series)
Operating temp.
-25 to +80 °C
Continuous mining & industrial duty
Min. bend radius
10 × OD
Fixed installation / dynamic routing
Core / conductor
3×35–150+3×E/3
Class 5 tinned Cu + 3 split earths
Outer protection
5GM5 Red CR
Anti-torsion braid + 5GM5 rubber
Standard
VDE 0250-813
DIN VDE 0250-813 / DIN VDE 0295

Typical values for this cable type, based on DIN VDE 0250-813 / DIN VDE 0295 — confirmed in the datasheet and quotation for your order.

Application fit

Is R-(N)TSCGEWTOEUS right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / DIN VDE 0295 across -25 to +80 °C.

Motorised monospiral reel

Suitable

Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-813 / DIN VDE 0295 within 10 × OD.

Trailing & towing

Suitable

Suitable for mobile mining loader, shuttle car and excavator trailing service across -25 to +80 °C.

Mine roadway & tunnel wall hangers

Suitable

Verified for underground mining galleries, tunnel faces and open-cast haulage paths.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: R-(N)TSCGEWTOEUS (DIN VDE 0250-813 / DIN VDE 0295) featuring phase conductors (3×50 mm²), triple-extruded mv dielectric and outer sheath (5gm5 red cr) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (3×50 mm²)DIN VDE 0295 Class 5 flexible tinned copper conductors
2Triple-Extruded MV DielectricInner semicon + 3GI3 EPR primary insulation + outer semicon screen (CGE)
3Bare Split Earth Conductors (3×25/3)Three uninsulated flexible tinned copper earth cores in outer interstices
4GM1b Inner Sheath & Polyester BraidVulcanized GM1b inner bedding + polyester anti-torsion braid (30 N/mm²)
5Outer Sheath (5GM5 Red CR)Heavy-duty red polychloroprene rubber jacket (DIN VDE 0207-21)

R-(N)TSCGEWTOEUS — Standard Mining Execution

Built to DIN VDE 0250-813 / DIN VDE 0295 with phase conductors (3×50 mm²) and outer sheath (5gm5 red cr)

R-(N)TSCGEWTOEUS — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

R-(N)TSCGEWTOEUS — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-813 / DIN VDE 0295. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
6/10 kV (DIN VDE 0250-813 / DIN VDE 0295)
Core / conductor construction
Phase Conductors (3×50 mm²) — DIN VDE 0295 Class 5 flexible tinned copper conductors
Primary dielectric / buffering
Triple-Extruded MV Dielectric — Inner semicon + 3GI3 EPR primary insulation + outer semicon screen (CGE)

Thermal

Continuous operating temperature
-25 to +80 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per DIN VDE 0250-813 / DIN VDE 0295
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Outer Sheath (5GM5 Red CR) — Heavy-duty red polychloroprene rubber jacket (DIN VDE 0207-21)
Minimum bending radius
10 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per DIN VDE 0250-813 / DIN VDE 0295

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per DIN VDE 0250-813 / DIN VDE 0295
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per DIN VDE 0250-813 / DIN VDE 0295
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0250-813 / DIN VDE 0295
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
R-(N)TSCGEWTOEUS
Sheath colour & metre marking
Continuous metre-marked red mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard R-(N)TSCGEWTOEUS mining & industrial configurations

Manufactured to DIN VDE 0250-813 / DIN VDE 0295 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
R-(N)TSCGEWTOEUS Construction Schedule (-25 to +80 °C)
R-(N)TSCGEWTOEUS 3×35 + 3×25/3 6/10 kV3 × 35 mm² + 3 × 25/3 mm² (E)Class 5 tinned Cu44.82,8903.2450
R-(N)TSCGEWTOEUS 3×50 + 3×25/3 6/10 kV3 × 50 mm² + 3 × 25/3 mm² (E)Class 5 tinned Cu48.23,5404.5485
R-(N)TSCGEWTOEUS 3×95 + 3×50/3 6/10 kV3 × 95 mm² + 3 × 50/3 mm² (E)Class 5 tinned Cu58.65,6208.6590
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN VDE 0250-813 / DIN VDE 0295.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN VDE 0250-813 / DIN VDE 0295)DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-813 / DIN VDE 0295 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN VDE 0250-813 / DIN VDE 0295)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250-813 / DIN VDE 0295)Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0250-813 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX R-(N)TSCGEWTOEUS VDE 0250-813 6/10 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define R-(N)TSCGEWTOEUS (R-(N)TSCGEWTOEUS 6/10 kV Anti-Torsion MV Reeling Cable)?
R-(N)TSCGEWTOEUS (R-(N)TSCGEWTOEUS 6/10 kV Anti-Torsion MV Reeling Cable) is manufactured in accordance with DIN VDE 0250-813 / DIN VDE 0295 for 6/10 kV duty over -25 to +80 °C. Its 5-layer construction comprises Phase Conductors (3×50 mm²), Triple-Extruded MV Dielectric and Outer Sheath (5GM5 Red CR).
What is the minimum bending radius and operating temperature range for R-(N)TSCGEWTOEUS?
The minimum bending radius for R-(N)TSCGEWTOEUS is 10 × OD across its continuous operating temperature range of -25 to +80 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of R-(N)TSCGEWTOEUS arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (3×50 mm²) (DIN VDE 0295 Class 5 flexible tinned copper conductors); (02) Triple-Extruded MV Dielectric (Inner semicon + 3GI3 EPR primary insulation + outer semicon screen (CGE)); (03) Bare Split Earth Conductors (3×25/3) (Three uninsulated flexible tinned copper earth cores in outer interstices); (04) GM1b Inner Sheath & Polyester Braid (Vulcanized GM1b inner bedding + polyester anti-torsion braid (30 N/mm²)); (05) Outer Sheath (5GM5 Red CR) (Heavy-duty red polychloroprene rubber jacket (DIN VDE 0207-21)).
What factory test certificates are supplied with R-(N)TSCGEWTOEUS?
Every production drum of R-(N)TSCGEWTOEUS undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN VDE 0250-813 / DIN VDE 0295, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for R-(N)TSCGEWTOEUS

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

R-(N)TSCGEWTOEUS 6/10 kV Anti-Torsion MV Reeling Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote