Motorised monospiral reel
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-813 / DIN VDE 0295 within 10 × OD.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / DIN VDE 0295 across -25 to +80 °C.
Typical values for this cable type, based on DIN VDE 0250-813 / DIN VDE 0295 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-813 / DIN VDE 0295 across -25 to +80 °C.
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-813 / DIN VDE 0295 within 10 × OD.
Suitable for mobile mining loader, shuttle car and excavator trailing service across -25 to +80 °C.
Verified for underground mining galleries, tunnel faces and open-cast haulage paths.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: R-(N)TSCGEWTOEUS (DIN VDE 0250-813 / DIN VDE 0295) featuring phase conductors (3×50 mm²), triple-extruded mv dielectric and outer sheath (5gm5 red cr) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×50 mm²) | DIN VDE 0295 Class 5 flexible tinned copper conductors |
| 2 | Triple-Extruded MV Dielectric | Inner semicon + 3GI3 EPR primary insulation + outer semicon screen (CGE) |
| 3 | Bare Split Earth Conductors (3×25/3) | Three uninsulated flexible tinned copper earth cores in outer interstices |
| 4 | GM1b Inner Sheath & Polyester Braid | Vulcanized GM1b inner bedding + polyester anti-torsion braid (30 N/mm²) |
| 5 | Outer Sheath (5GM5 Red CR) | Heavy-duty red polychloroprene rubber jacket (DIN VDE 0207-21) |
Built to DIN VDE 0250-813 / DIN VDE 0295 with phase conductors (3×50 mm²) and outer sheath (5gm5 red cr)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to DIN VDE 0250-813 / DIN VDE 0295 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| R-(N)TSCGEWTOEUS Construction Schedule (-25 to +80 °C) | |||||||
| R-(N)TSCGEWTOEUS 3×35 + 3×25/3 6/10 kV | 3 × 35 mm² + 3 × 25/3 mm² (E) | Class 5 tinned Cu | 44.8 | 2,890 | 3.2 | 450 | |
| R-(N)TSCGEWTOEUS 3×50 + 3×25/3 6/10 kV | 3 × 50 mm² + 3 × 25/3 mm² (E) | Class 5 tinned Cu | 48.2 | 3,540 | 4.5 | 485 | |
| R-(N)TSCGEWTOEUS 3×95 + 3×50/3 6/10 kV | 3 × 95 mm² + 3 × 50/3 mm² (E) | Class 5 tinned Cu | 58.6 | 5,620 | 8.6 | 590 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 35 mm² + 3 × 25/3 mm² (6/10 kV) | 0.57 | 6/10 kV (169 A) | -25 to +80 °C |
| 3 × 50 mm² + 3 × 25/3 mm² (6/10 kV) | 0.39 | 6/10 kV (206 A) | -25 to +80 °C |
| 3 × 95 mm² + 3 × 50/3 mm² (6/10 kV) | 0.21 | 6/10 kV (308 A) | -25 to +80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-813 / DIN VDE 0295) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-813 / DIN VDE 0295 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-813 / DIN VDE 0295) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250-813 / DIN VDE 0295) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.