Switchgear & control cabinet wiring
Triple concentric tinned copper screens provide guarded return, transient return and grounded outer safety shield.
Product
QUADRAXIAL HV 2241 75 kVDC triple-concentric-screened quadraxial HV cable featuring an AWG 14 silver-plated copper core, primary semicon/EPR 75 kVDC stack, dual isolated copper braids, secondary EPR HV barrier, outer braid 3 and a black sheath.
Typical values for this cable type, based on IEC 60502 / MIL-DTL-17 — confirmed in the datasheet and quotation for your order.
Application fit
QUADRAXIAL HV 2241 75 kVDC triple-concentric-screened quadraxial HV cable featuring an AWG 14 silver-plated copper core, primary semicon/EPR 75 kVDC stack, dual isolated copper braids, secondary EPR HV barrier, outer braid 3 and a black sheath.
Triple concentric tinned copper screens provide guarded return, transient return and grounded outer safety shield.
Inner and secondary semiconductive EPR layers eliminate corona and partial discharge up to 75 kVDC.
Low-inductance concentric geometry supports fast high-voltage pulse modulators, Marx generators and klystrons.
Heavy multi-barrier 75 kVDC quadraxial laboratory and modulator feeder; not for mobile reeling drums.
(N)7YRDGOEU-JConstruction
Shown: QUADRAXIAL HV 2241 (IEC 60502 / MIL-DTL-17) featuring center conductor (awg 14), primary 75 kvdc epr stack and shield 3 & outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center Conductor (AWG 14) | 19 x AWG 27 (2.08 mm², AWG 14) concentric stranded silver-plated copper center conductor (OD 1.85 mm)IEC 60502 / MIL-DTL-17 |
| 2 | Primary 75 kVDC EPR Stack | Extruded inner semiconductive EPR stress layer, primary 75 kVDC EPR dielectric (OD 8.89 mm), and outer semiconductive EPR layerIEC 60502 / MIL-DTL-17 |
| 3 | Shields 1 & 2 + Mylar Barrier | Inner tinned copper braid Shield 1 and intermediate tinned copper braid Shield 2 electrically isolated by a Mylar polyester dielectric wrapIEC 60502 / MIL-DTL-17 |
| 4 | Secondary EPR HV Stack | Secondary semiconductive EPR stress layer, secondary high-voltage EPR isolation layer, and outer semiconductive EPR screenIEC 60502 / MIL-DTL-17 |
| 5 | Shield 3 & Outer Jacket | Outer tinned copper braid Shield 3, Mylar separator tape, and heavy-duty black elastomeric outer jacket (OD 19.30 mm)IEC 60502 / MIL-DTL-17 |
Built to IEC 60502 / MIL-DTL-17 with center conductor (awg 14) and shield 3 & outer jacket
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60502 / MIL-DTL-17 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| QUADRAXIAL HV 2241 Construction Schedule (−40…+120 °C) | |||||||
| QUADRAXIAL HV 2240 (50 kVDC AWG 14) | AWG 14 (2.08 mm²) + 3×Cu Screen | 19×AWG 27 SPC + dual EPR stack | 16.5 | 410 | 1.4 | 165 | |
| QUADRAXIAL HV 2241 (75 kVDC AWG 14) | AWG 14 (2.08 mm²) + 3×Cu Screen | 19×AWG 27 SPC + dual EPR stack | 20.4 | 595 | 1.8 | 205 | |
| QUADRAXIAL HV 2242 (100 kVDC AWG 12) | AWG 12 (3.31 mm²) + 3×Cu Screen | 19×AWG 25 SPC + dual EPR stack | 24.8 | 840 | 2.5 | 250 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| AWG 14 + 3×Screen (50 kVDC) | 8.90 | 50 kVDC (110 kVDC test) | −40…+120 °C |
| AWG 14 + 3×Screen (75 kVDC) | 8.90 | 75 kVDC (150 kVDC test) | −40…+120 °C |
| AWG 12 + 3×Screen (100 kVDC) | 5.60 | 100 kVDC (190 kVDC test) | −40…+120 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60502 / MIL-DTL-17) | Electrical parameters and outer diameter within IEC 60502 / MIL-DTL-17 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60502 / MIL-DTL-17) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60502 / MIL-DTL-17) | Verified structural and dielectric integrity across −40…+120 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.