Motorised monospiral reel
Engineered for compact spring-operated and motorised horizontal cable reels with high travel speed.
Product
(N)7YRDGOEU-J 0.6/1 kV compact spring-reeling power and control cable combining extra-fine Class FS copper conductors, thin-wall ETFE core insulation, EPR inner sheath, anti-torsion braid and a crosslinked EVA outer sheath.
Typical values for this cable type, based on DIN VDE 0250-814 / IEC 60228 — confirmed in the datasheet and quotation for your order.
Application fit
(N)7YRDGOEU-J 0.6/1 kV compact spring-reeling power and control cable combining extra-fine Class FS copper conductors, thin-wall ETFE core insulation, EPR inner sheath, anti-torsion braid and a crosslinked EVA outer sheath.
Engineered for compact spring-operated and motorised horizontal cable reels with high travel speed.
Anti-torsion synthetic braid stabilizes core lay during vertical reeling and spreader basket operation.
Suitable for crane festoon trolleys and outdoor gantry handling across −40…+90 °C.
Suitable for medium-duty energy chains when minimum bend radius of 7.5 × OD is maintained.
Construction
Shown: (N)7YRDGOEU-J (DIN VDE 0250-814 / IEC 60228) featuring extra-fine conductors (4g4 mm²), etfe core insulation (7y) and eva outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Extra-Fine Conductors (4G4 mm²) | Class FS extra-finely stranded plain annealed copper conductors engineered for compact spring-operated reeling drumsDIN VDE 0250-814 / IEC 60228 |
| 2 | ETFE Core Insulation (7Y) | High-strength extruded ethylene tetrafluoroethylene (ETFE) fluoropolymer core insulation (numbered black cores + green/yellow PE)DIN VDE 0250-814 / IEC 60228 |
| 3 | Inner Elastomeric Sheath | Extruded black special ethylene propylene rubber (EPR) inner bedding sheath stabilizing the core lay under reeling tensionDIN VDE 0250-814 / IEC 60228 |
| 4 | Anti-Torsion Braid | High-tenacity synthetic textile anti-torsion reinforcement braid vulkanized between inner and outer elastomeric sheathsDIN VDE 0250-814 / IEC 60228 |
| 5 | EVA Outer Sheath | Heavy-duty crosslinked ethylene vinyl acetate (EVA) outer jacket resistant to oil, ozone, UV, and mechanical abrasionDIN VDE 0250-814 / IEC 60228 |
Built to DIN VDE 0250-814 / IEC 60228 with extra-fine conductors (4g4 mm²) and eva outer sheath
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to DIN VDE 0250-814 / IEC 60228 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| (N)7YRDGOEU-J Construction Schedule (−40…+90 °C) | |||||||
| (N)7YRDGOEU-J 4G2.5 | 4G2.5 mm² | Class FS extra-fine Cu | 11.2 | 195 | 1.2 | 70 | |
| (N)7YRDGOEU-J 4G4 | 4G4 mm² | Class FS extra-fine Cu | 12.8 | 265 | 1.9 | 80 | |
| (N)7YRDGOEU-J 4G6 | 4G6 mm² | Class FS extra-fine Cu | 14.4 | 355 | 2.8 | 90 | |
| (N)7YRDGOEU-J 7G2.5 | 7G2.5 mm² | Class FS extra-fine Cu | 14.1 | 310 | 2.1 | 85 | |
| (N)7YRDGOEU-J 12G1.5 | 12G1.5 mm² | Class FS extra-fine Cu | 15.6 | 365 | 2.2 | 95 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 4G2.5 mm² | 7.98 | 0.6/1 kV / 26 A | −40…+90 °C |
| 4G4 mm² | 4.95 | 0.6/1 kV / 34 A | −40…+90 °C |
| 4G6 mm² | 3.30 | 0.6/1 kV / 44 A | −40…+90 °C |
| 7G2.5 mm² | 7.98 | 0.6/1 kV / 20 A | −40…+90 °C |
| 12G1.5 mm² | 13.30 | 0.6/1 kV / 13 A | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (DIN VDE 0250-814 / IEC 60228) | Electrical parameters and outer diameter within DIN VDE 0250-814 / IEC 60228 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-814 / IEC 60228) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (DIN VDE 0250-814 / IEC 60228) | Verified structural and dielectric integrity across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.