Mine roadway & tunnel wall hangers
Primary MV flexible feeder linking underground flameproof transformer stations along advancing roadways.
Product
OnGcekgż-G is a Polish-standard 3.6/6 kV and 6/10 kV medium-voltage screened flexible mining rubber cable to PN-G-90105 for high-voltage longwall shearers, mobile underground transformer stations, and roadheaders. It features triple-extruded +90 °C EPR
Typical values for this cable type, based on PN-G-90105 / ZN-TF-210 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for 3.3 kV, 6 kV, and 10 kV underground mobile flameproof substations, high-power longwall shearer faces, and roadway MV trailing feeders.
Primary MV flexible feeder linking underground flameproof transformer stations along advancing roadways.
Supplies 3.3–6 kV longwall shearers, crushers, and mobile heading machines.
Elastomeric 'ekg' screens withstand cyclic bending in large-radius MV Bretby handlers.
Suitable for low-tension MV monospiral reels; use NTSCGEWÖU for high-speed crane reeling.
NTSCGEWÖU 3.6/6–18/30 kVIdeal for shaft-bottom to district-substation MV interconnections on gallery hangers.
Construction
Three MV EPR phase cores with inner/outer semi-conductive rubber stress control and metallic-elastomeric screens ('ekg'), pilot core
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible copper phase conductor | Class 5 fine-stranded plain or tinned annealed copper wireIEC 60228 Class 5 |
| 2 | Inner conductor stress-control screen | Extruded semi-conductive rubber layer smoothing conductor strand electric fieldPN-G-90105 |
| 3 | Medium-voltage +90 °C EPR dielectric | Ozone- and partial-discharge-resistant cross-linked ethylene-propylene rubberPN-G-90105 |
| 4 | Outer semi-conductive & composite | Vulcanised semi-conductive rubber layer combined with copper/elastomeric phase screeningPN-G-90105 |
| 5 | Pilot core(s) ('ż') & earth conductor | Screened pilot control core(s) and bare flexible copper protective earth conductorPN-G-90105 |
| 6 | Underground MV mining outer sheath | Heavy-duty flame-retardant, oil- and tear-resistant polychloroprene (PCP) compound, redPN-G-90105 |
Medium-voltage screened mining cable for 3.3 kV and 6 kV longwall face machines and mobile transformers.
10 kV district roadway feeder and mobile substation trailing cable with full radial field control.
Technical data
Sizes
Nominal dimensions, copper weights and electrical parameters for OnGcekgż-G per PN-G-90105 / ZN-TF-210.
| Order designation | Voltage & Configuration | Phase size mm² | Outer Ø ≈ mm | Copper kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 3.6/6 kV (Um 7.2 kV) OnGcekgż-G medium-voltage mining | |||||||
| OnGcekgż-G 3.6/6 kV 3×16+1×16+1×6 | 3.6/6 kV 3×16+1×16+1×6 | 16 | 39.5 | 672 | 2,120 | 237 | |
| OnGcekgż-G 3.6/6 kV 3×25+1×16+1×6 | 3.6/6 kV 3×25+1×16+1×6 | 25 | 43.2 | 931 | 2,590 | 259 | |
| OnGcekgż-G 3.6/6 kV 3×35+1×16+1×6 | 3.6/6 kV 3×35+1×16+1×6 | 35 | 46.0 | 1,219 | 3,040 | 276 | |
| OnGcekgż-G 3.6/6 kV 3×50+1×25+1×6 | 3.6/6 kV 3×50+1×25+1×6 | 50 | 50.8 | 1,738 | 3,840 | 305 | |
| OnGcekgż-G 3.6/6 kV 3×70+1×35+1×6 | 3.6/6 kV 3×70+1×35+1×6 | 70 | 55.6 | 2,410 | 4,790 | 334 | |
| OnGcekgż-G 3.6/6 kV 3×95+1×50+1×6 | 3.6/6 kV 3×95+1×50+1×6 | 95 | 61.2 | 3,274 | 6,010 | 367 | |
| 6/10 kV (Um 12 kV) OnGcekgż-G medium-voltage mining | |||||||
| OnGcekgż-G 6/10 kV 3×25+1×16+1×6 | 6/10 kV 3×25+1×16+1×6 | 25 | 47.5 | 931 | 2,980 | 285 | |
| OnGcekgż-G 6/10 kV 3×35+1×16+1×6 | 6/10 kV 3×35+1×16+1×6 | 35 | 50.4 | 1,219 | 3,460 | 302 | |
| OnGcekgż-G 6/10 kV 3×50+1×25+1×6 | 6/10 kV 3×50+1×25+1×6 | 50 | 55.2 | 1,738 | 4,310 | 331 | |
| OnGcekgż-G 6/10 kV 3×70+1×35+1×6 | 6/10 kV 3×70+1×35+1×6 | 70 | 60.0 | 2,410 | 5,320 | 360 | |
| OnGcekgż-G 6/10 kV 3×95+1×50+1×6 | 6/10 kV 3×95+1×50+1×6 | 95 | 65.8 | 3,274 | 6,620 | 395 | |
| OnGcekgż-G 6/10 kV 3×120+1×50+1×6 | 6/10 kV 3×120+1×50+1×6 | 120 | 70.2 | 3,994 | 7,740 | 421 | |
| Configuration | Max. DC R @ 20 °C Ω/km | Current rating in air (A) | Current rating installed (A) | Mutual C pF/m ≈ | AC test V rms |
|---|---|---|---|---|---|
| 3.6/6 kV 3×16+1×16+1×6 | 1.210 | 93 | 79 | 101 | 11,000 |
| 3.6/6 kV 3×25+1×16+1×6 | 0.780 | 123 | 105 | 114 | 11,000 |
| 3.6/6 kV 3×35+1×16+1×6 | 0.554 | 152 | 129 | 129 | 11,000 |
| 3.6/6 kV 3×50+1×25+1×6 | 0.386 | 189 | 161 | 150 | 11,000 |
| 3.6/6 kV 3×70+1×35+1×6 | 0.272 | 233 | 198 | 180 | 11,000 |
| 3.6/6 kV 3×95+1×50+1×6 | 0.206 | 282 | 240 | 216 | 11,000 |
| 6/10 kV 3×25+1×16+1×6 | 0.780 | 123 | 105 | 114 | 17,000 |
| 6/10 kV 3×35+1×16+1×6 | 0.554 | 152 | 129 | 129 | 17,000 |
| 6/10 kV 3×50+1×25+1×6 | 0.386 | 189 | 161 | 150 | 17,000 |
| 6/10 kV 3×70+1×35+1×6 | 0.272 | 233 | 198 | 180 | 17,000 |
| 6/10 kV 3×95+1×50+1×6 | 0.206 | 282 | 240 | 216 | 17,000 |
| 6/10 kV 3×120+1×50+1×6 | 0.161 | 326 | 277 | 252 | 17,000 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| MV AC dielectric withstand test | 11 kV rms (3.6/6 kV) or 17 kV rms (6/10 kV) for 5 minutes | Every manufactured drum |
| Partial discharge (PD) measurement | ≤ 20 pC at 1.5 × U0 across full drum length | Every manufactured drum |
| Sample tests | ||
| Semi-conductive stress-control resistivity | Inner & outer semicon resistivity verified before/after ageing per PN-G-90105 | Per batch |
| Flame propagation & impulse voltage test | Passes PN-EN 60332-1-2 and lightning impulse withstand test | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.