Motorised monospiral reel
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-812 / DIN EN 60228 within 8 × OD.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-812 / DIN EN 60228 across -25 to +80 °C.
Typical values for this cable type, based on DIN VDE 0250-812 / DIN EN 60228 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-812 / DIN EN 60228 across -25 to +80 °C.
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250-812 / DIN EN 60228 within 8 × OD.
Suitable for mobile mining loader, shuttle car and excavator trailing service across -25 to +80 °C.
Verified for underground mining galleries, tunnel faces and open-cast haulage paths.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: NSSHUCGEÖU (DIN VDE 0250-812 / DIN EN 60228) featuring conductive cradle with aramid rope (u), phase cores (3×50 mm²) and 5gm5 black outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductive Cradle with Aramid Rope (U) | Central aramid strain-relief rope inside a conductive cradle separator |
| 2 | Phase Cores (3×50 mm²) | Class 5 tinned copper + polyester tape + Brown, Black & Grey 3GI3 EPR |
| 3 | Extensible Pilot/Earth Cores (3×) | Blue EPR 1.5ST pilot + concentric tinned Cu 25/3 earth + semicon tape |
| 4 | Semicon Inner Sheath & Torsion Braid | Semiconductive inner sheath + vulcanized polyester anti-torsion braid |
| 5 | 5GM5 Black Outer Sheath | Heavy-duty black chlorinated rubber compound 5GM5 outer jacket |
Built to DIN VDE 0250-812 / DIN EN 60228 with conductive cradle with aramid rope (u) and 5gm5 black outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to DIN VDE 0250-812 / DIN EN 60228 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| NSSHUCGEÖU Construction Schedule (-25 to +80 °C) | |||||||
| NSSHUCGEÖU 3×35/16 + 3×1.5ST | 3×35 + 3×16/3 (E) + 3×1.5ST | Class 5 tinned Cu + Aramid | 44.5 | 3,120 | 18.0 | 355 | |
| NSSHUCGEÖU 3×50/25 + 3×1.5ST | 3×50 + 3×25/3 (E) + 3×1.5ST | Class 5 tinned Cu + Aramid | 49.2 | 3,980 | 24.5 | 395 | |
| NSSHUCGEÖU 3×70/35 + 3×1.5ST | 3×70 + 3×35/3 (E) + 3×1.5ST | Class 5 tinned Cu + Aramid | 54.8 | 5,060 | 31.5 | 440 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×35 + 3×16/3 (E) + 3×1.5ST | 0.57 | 0.6/1 kV (158 A) | -25 to +80 °C |
| 3×50 + 3×25/3 (E) + 3×1.5ST | 0.39 | 0.6/1 kV (192 A) | -25 to +80 °C |
| 3×70 + 3×35/3 (E) + 3×1.5ST | 0.28 | 0.6/1 kV (246 A) | -25 to +80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-812 / DIN EN 60228) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-812 / DIN EN 60228 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-812 / DIN EN 60228) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250-812 / DIN EN 60228) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.