Immersion & wet locations
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
Product
(N)TSCGECEWÖU 3.6/6–12/20 kV (MV Submersible Individually Copper-Braided MV Submersible Pump/Dredger Cable) & MT PLUS 3.6/6 kV (WRAS/ACS MV Potable-Water Cable) (VDE 0250-813, 3.6/6 kV, -25 °C to +90 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on DIN VDE 0250-813 / WRAS / ACS — confirmed in the datasheet and quotation for your order.
Application fit
(N)TSCGECEWÖU 3.6/6–12/20 kV (MV Submersible Individually Copper-Braided MV Submersible Pump/Dredger Cable) & MT PLUS 3.6/6 kV (WRAS/ACS MV Potable-Water Cable) (VDE 0250-813, 3.6/6 kV, -25 °C to +90 °C, min. bend radius 10 × OD).
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.
Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.
Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.
Submersible rubber pump cable is not intended for high-acceleration automation drag chains.
Use Drag-Chain Control CableConstruction
Shown: (N)TSCGECEWÖU MT PLUS (DIN VDE 0250-813 / WRAS / ACS) featuring class 5 tinned copper mv conductors, triple-extruded 3gi3 epr mv insulation and 5gm3 cm / blue em6 potable-water sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Tinned Copper MV Conductors | Flexible stranded tinned copper conductors rated for 3.6/6 kV up to 12/20 kV |
| 2 | Triple-Extruded 3GI3 EPR MV Insulation | Semiconductive conductor screen + 3GI3 EPR dielectric + outer semiconductive screen |
| 3 | Individual Copper Braid Phase Screen (CE) | Each phase core has its own bare copper braid shield (or 3 split earths in MT PLUS) |
| 4 | Reinforced Cradle & GM1b Waterproof Inner | Central reinforced rubber cradle + semicon tape + waterproof GM1b EPR inner sheath |
| 5 | 5GM3 CM / Blue EM6 Potable-Water Sheath | Black 5GM3 CM (MV Submersible) or Blue WRAS/ACS EM6 (MT PLUS, 300 m) |
Built to DIN VDE 0250-813 / WRAS / ACS with class 5 tinned copper mv conductors and 5gm3 cm / blue em6 potable-water sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN VDE 0250-813 / WRAS / ACS for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| (N)TSCGECEWÖU MT PLUS Construction Schedule (−25…+90 °C) | |||||||
| (N)TSCGECEWÖU MT P 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| (N)TSCGECEWÖU MT P 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| (N)TSCGECEWÖU MT P 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 3.6/6 kV (94 A submerged) | −25…+90 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 3.6/6 kV (152 A submerged) | −25…+90 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 3.6/6 kV (235 A submerged) | −25…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-813 / WRAS / ACS) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-813 / WRAS / ACS tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-813 / WRAS / ACS) | Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0250-813 / WRAS / ACS) | Verified submersion integrity, tensile load and thermal stability across −25…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.