Contact
Underground coal cutter trailing cableDIN VDE 0250-8120.6/1 kV (Max 1.2 kV)Pliable Armour (-V)

(N)SSHCGEWÖU-V 0.6/1 kV Coal Cutter Trailing Cable(N)SSHCGEWÖU-V 0.6/1 kV underground coal cutter and shearer trailing cable per DIN VDE 0250-812, with 3GI3 EPR phase cores, 3 screened pilot/earth units, mixed steel/copper pliable armour (-V) and a 5GM5 yellow rubber jacket.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-812 / DIN EN 60228 across -25 to +80 °C.

EMC screen
Oil-resistant
Flame-retardant
Anti-torsion braid
Order designation
(N)SSHCGEWÖU-V 3×50/25 + 3×(2×1.5St+1.5ÜL)
Outer Ø ≈
57.8 mm
Net weight ≈
5,240 kg/km
Tensile rating ≈
22.5 kN
Core / stranding
Class 5 tinned Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Max. 1.2 kV three-phase AC
Operating temp.
-25 to +80 °C
Continuous mining & industrial duty
Min. bend radius
10 × OD
Fixed installation / dynamic routing
Core / conductor
3×35–95 mm² SnCu
Class 5 tinned Cu + 3×(2×1.5St+1.5ÜL)
Outer protection
5GM5 Yellow CR
Pliable armour + 5GM5 rubber sheath
Standard
VDE 0250-812
DIN VDE 0250-812 / DIN EN 60228

Typical values for this cable type, based on DIN VDE 0250-812 / DIN EN 60228 — confirmed in the datasheet and quotation for your order.

Application fit

Is (N)SSHCGEWÖU-V right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250-812 / DIN EN 60228 across -25 to +80 °C.

Trailing & towing

Suitable

Engineered for heavy-duty mobile mining and industrial trailing duty per DIN VDE 0250-812 / DIN EN 60228.

Mine roadway & tunnel wall hangers

Suitable

Suitable for underground coal/hard-rock roadways, shuttle cars and quarry feeders (-25 to +80 °C).

Fixed installation

Suitable

Can be installed on cable trays, hangers and mobile skid interconnections within 10 × OD.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: (N)SSHCGEWÖU-V (DIN VDE 0250-812 / DIN EN 60228) featuring phase cores (3×50 mm²), 3 control units: 3×(2×1.5st + 1.5ül) and outer sheath (5gm5 yellow) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Cores (3×50 mm²)Class 5 tinned copper + 3GI3 EPR insulation + semiconductive elastomer screen
23 Control Units: 3×(2×1.5St + 1.5ÜL)Each unit has 2×3GI3 EPR control cores + 1×1.5ÜL monitor core in semicon screen
3Black GM1b Inner BeddingCrosslinked black GM1b elastomeric inner sheath rounding the core assembly
4Reinforced Pliable Armour/Screen (-V)Mixed galvanized steel & tinned copper wire braid screen and armour
5Outer Sheath (5GM5 Yellow)High-visibility yellow heavy-duty polychloroprene rubber jacket

(N)SSHCGEWÖU-V — Standard Mining Execution

Built to DIN VDE 0250-812 / DIN EN 60228 with phase cores (3×50 mm²) and outer sheath (5gm5 yellow)

(N)SSHCGEWÖU-V — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

(N)SSHCGEWÖU-V — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-812 / DIN EN 60228. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (DIN VDE 0250-812 / DIN EN 60228)
Core / conductor construction
Phase Cores (3×50 mm²) — Class 5 tinned copper + 3GI3 EPR insulation + semiconductive elastomer screen
Primary dielectric / buffering
3 Control Units: 3×(2×1.5St + 1.5ÜL) — Each unit has 2×3GI3 EPR control cores + 1×1.5ÜL monitor core in semicon screen

Thermal

Continuous operating temperature
-25 to +80 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per DIN VDE 0250-812 / DIN EN 60228
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Outer Sheath (5GM5 Yellow) — High-visibility yellow heavy-duty polychloroprene rubber jacket
Minimum bending radius
10 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per DIN VDE 0250-812 / DIN EN 60228

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per DIN VDE 0250-812 / DIN EN 60228
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per DIN VDE 0250-812 / DIN EN 60228
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0250-812 / DIN EN 60228
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
(N)SSHCGEWÖU-V
Sheath colour & metre marking
Continuous metre-marked yellow mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard (N)SSHCGEWÖU-V mining & industrial configurations

Manufactured to DIN VDE 0250-812 / DIN EN 60228 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
(N)SSHCGEWÖU-V Construction Schedule (-25 to +80 °C)
(N)SSHCGEWÖU-V 3×35/16 + 3×(2×1.5St+1.5ÜL)3×35/16 + 3×(2×1.5St+1.5ÜL)Class 5 tinned Cu53.54,38015.8535
(N)SSHCGEWÖU-V 3×50/25 + 3×(2×1.5St+1.5ÜL)3×50/25 + 3×(2×1.5St+1.5ÜL)Class 5 tinned Cu57.85,24022.5580
(N)SSHCGEWÖU-V 3×70/35 + 3×(2×1.5St+1.5ÜL)3×70/35 + 3×(2×1.5St+1.5ÜL)Class 5 tinned Cu63.26,49031.5635
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN VDE 0250-812 / DIN EN 60228.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN VDE 0250-812 / DIN EN 60228)DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-812 / DIN EN 60228 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN VDE 0250-812 / DIN EN 60228)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250-812 / DIN EN 60228)Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0250-812 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX (N)SSHCGEWÖU-V VDE 0250-812 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define (N)SSHCGEWÖU-V ((N)SSHCGEWÖU-V 0.6/1 kV Coal Cutter Trailing Cable)?
(N)SSHCGEWÖU-V ((N)SSHCGEWÖU-V 0.6/1 kV Coal Cutter Trailing Cable) is manufactured in accordance with DIN VDE 0250-812 / DIN EN 60228 for 0.6/1 kV duty over -25 to +80 °C. Its 5-layer construction comprises Phase Cores (3×50 mm²), 3 Control Units: 3×(2×1.5St + 1.5ÜL) and Outer Sheath (5GM5 Yellow).
What is the minimum bending radius and operating temperature range for (N)SSHCGEWÖU-V?
The minimum bending radius for (N)SSHCGEWÖU-V is 10 × OD across its continuous operating temperature range of -25 to +80 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of (N)SSHCGEWÖU-V arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Cores (3×50 mm²) (Class 5 tinned copper + 3GI3 EPR insulation + semiconductive elastomer screen); (02) 3 Control Units: 3×(2×1.5St + 1.5ÜL) (Each unit has 2×3GI3 EPR control cores + 1×1.5ÜL monitor core in semicon screen); (03) Black GM1b Inner Bedding (Crosslinked black GM1b elastomeric inner sheath rounding the core assembly); (04) Reinforced Pliable Armour/Screen (-V) (Mixed galvanized steel & tinned copper wire braid screen and armour); (05) Outer Sheath (5GM5 Yellow) (High-visibility yellow heavy-duty polychloroprene rubber jacket).
What factory test certificates are supplied with (N)SSHCGEWÖU-V?
Every production drum of (N)SSHCGEWÖU-V undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN VDE 0250-812 / DIN EN 60228, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for (N)SSHCGEWÖU-V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

(N)SSHCGEWÖU-V 0.6/1 kV Coal Cutter Trailing Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote